• Title/Summary/Keyword: $CO_2$ leakage

Search Result 381, Processing Time 0.025 seconds

Application of Cyber Physical System (CPS) for Risk Management of a CO2 Storage Site (이산화탄소 저장부지 위해성 관리를 위한 가상물리시스템 적용성 평가)

  • Jeong, Jina;Park, Eungyu;Jun, Seong-Chun;Kim, Hyun-Jun;Yun, Seong-Taek
    • Economic and Environmental Geology
    • /
    • v.50 no.5
    • /
    • pp.363-373
    • /
    • 2017
  • In the present study, adaptability of cyber-physical system (CPS) for risk management of $CO_2$ storage site is examined and the subagging regression (SBR) method is proposed as a key component of the cyber-twin to estimate the risk due to potential $CO_2$ leakage. For these purposes, $CO_2$ concentration data monitored from a controlled $CO_2$ release field experiment is employed to validate the potentialities of the SBR method. From the validation study, it is found that the SBR method has robust estimation capability by showing minimal influence from anomalous measurements, and makes stable and sound predictions for the forthcoming $CO_2$ concentration trend. In addition, the method is found to be well suited as a tool of operational risk assessment based on real-time monitoring data due to the computational efficiency. The overall results suggest that the SBR method has potential to be an important component comprising the cyber twin of CPS for risk management of $CO_2$ storage site.

Evaluation on the Basic Properties of Phosphate Modified Portland Cement Paste for Potential Application of Geologic CO2 Sequestration (이산화탄소 지중 격리용 인산염 혼입 시멘트 페이스트에 관한 기초물성 평가)

  • Yoon, Ju-Han;Kim, Seong-Geun;Kim, Ji-Hyun;Lee, Jae-Yong;Chung, Chul-Woo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.3
    • /
    • pp.253-260
    • /
    • 2017
  • As global warming became a worldwide issue, a significant effort has been made on the development of technology related to $CO_2$ capture and storage. Geologic sequestration of $CO_2$ is one of those technologies for safe disposal of $CO_2$. Geologic sequestration stores $CO_2$ in the form of supercritical fluid into the underground site surrounded by solid rock, and concrete is used for prevention of $CO_2$ leakage into the atmosphere. In such case, concrete may experience severe damage by attack of supercritical $CO_2$, and especially in contact with underground water, very aggressive form of carbonation can occur. In this work, to prevent such deterioration in concrete, calcium phosphates were added to the portland cement to produce hydroxyapatite, one of the most stable mineral in the world. Temperature rise, viscosity, set and stiffening, and strength development of cement paste incorporating three different types of calcium phosphates were investigated. According to the results, it was found that the addition of calcium phosphate increased apparent viscosity, but decreased maximum temperature rise and 28 day compressive strength. It was found that monocalcium phosphate was found to be inappropriate for portland cement based material. Applicability of dicalcium and tricalcium phosphates for portland cement needs to be evaluated with further investigation, including the long term compressive strength development.

Thermal Stability and Electrical Properties of HfOxNy Gate Dielectrics with TaN Gate Electrode

  • Kim Jeon-Ho;Choi Kyu-Jeong;Seong Nak-Jin;Yoon Soon-Gil;Lee Won-Jae;Kim Jin-dong;Shin Woong-Chul;Ryu Sang-Ouk;Yoon Sung-Min;Yu Byoung-Gon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.4 no.3
    • /
    • pp.34-37
    • /
    • 2003
  • [ $HfO_2$ ] and $HfO_xN_y$ films were deposited by plasma-enhanced chemical vapor deposition using $Hf[OC(CH_3)_3]_4$ as the precursor in the absence of $O_2$. The crystallization temperature of the $HfO_xN_y$ films is higher than that of the $HfO_2$ film. Nitrogen incorporation in $HfO_xN_y$ was confirmed by auger electron spectroscopy analysis. After post deposition annealing (PDA) at 800$\Box$, the EOT increased from 1.34 to 1.6 nm in the $HfO_2$ thin films, whereas the increase of EOT was suppressed to less than 0.02 nm in the $HfO_xN_y$. The leakage current density decreased from 0.18 to 0.012 $A/cm^2$ with increasing PDA temperature in the $HfO_2$ films. But the leakage current density of $HfO_xN_y$ does not vary with increasing PDA temperature because an amorphous $HfO_xN_y$ films suppresses the diffusion of oxygen through the gate dielectric.

Effect of Low-Temperature Sintering on Electrical Properties and Aging Behavior of ZVMNBCD Varistor Ceramics

  • Nahm, Choon-Woo
    • Korean Journal of Materials Research
    • /
    • v.30 no.10
    • /
    • pp.502-508
    • /
    • 2020
  • This paper focuses on the electrical properties and stability against DC accelerated aging stress of ZnO-V2O5-MnO2-Nb2O5-Bi2O3-Co3O4-Dy2O3 (ZVMNBCD) varistor ceramics sintered at 850 - 925 ℃. With the increase of sintering temperature, the average grain size increases from 4.4 to 11.8 mm, and the density of the sintered pellets decreases from 5.53 to 5.40 g/㎤ due to the volatility of V2O5, which has a low melting point. The breakdown field abruptly decreases from 8016 to 1,715 V/cm with the increase of the sintering temperature. The maximum non-ohmic coefficient (59) is obtained when the sample is sintered at 875 ℃. The samples sintered at below 900 ℃ exhibit a relatively low leakage current, less than 60 mA/㎠. The apparent dielectric constant increases due to the increase of the average grain size with the increase of the sintering temperature. The change tendency of dissipation factor at 1 kHz according to the sintering temperature coincides with the tendency of the leakage current. In terms of stability, the samples sintered at 900 ℃ exhibit both high non-ohmic coefficient (45) and excellent stability, 0.8% in 𝚫EB/EB and -0.7 % in 𝚫α/α after application of DC accelerated aging stress (0.85 EB/85 ℃/24 h).

Effect of postharvest conditions on the characteristics of mulberries harvested from various mulberry cultivar Morus alba

  • Kim, Hyun-Bok;Kwon, O-Chul;Kweon, HaeYong;Jo, You-Young;Ju, Wan-Teak;Lee, Ji Hae;Kim, Yong-Soon
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.40 no.2
    • /
    • pp.33-40
    • /
    • 2020
  • Recently mulberry has been commercialized but it loses its marketability rapidly after harvest. In this study, characteristics of mulberry were examined at different storage temperature after harvest using the typical Korean mulberry cultivars. Postharvest spoilage fungi on the various mulberry cultivars, Cheongilppong, Daeshim, and Gwasang No. 2 was observed 2, 2, and 1 d, respectively, after harvest at 28℃. However, at 4℃, the day was 8, 7, and 4 d, respectively. At 28℃ storage condition, the weight loss behavior of mulberry did not showed significantly different among them. However, at 4℃ storage condition, mulberry Cheongilppong loses its weight rapidly compared to Daeshim and Gwasang No. 2. Sugar content of mulberry stored at 4℃ was nearly constant, but stored at 28℃ decreased with storage time. The acidity of mulberry slightly decreased with storage time and then increased. Juice leakage of frozen mulberry leaked abruptly within 6 h from the fruit body and then flattened at 25℃. The results of our study, the postharvest characteristics of mulberry were affected by mulberry cultivar and need to further study to increase the shelf life.

Clinical assessment of the efficacy of supraglottic airway devices compared with endotracheal tubes in cats during volume-controlled ventilation

  • Niyatiwatchanchai, Nutawan;Thengchaisri, Naris
    • Journal of Veterinary Science
    • /
    • v.21 no.2
    • /
    • pp.27.1-27.10
    • /
    • 2020
  • The efficacies of a supraglottic airway device (SGAD) and an endotracheal tube (ETT) in cats under general anesthesia with volume-controlled ventilation (VCV) were compared. Thirty healthy cats were randomly allocated for airway control using either an SGAD or an ETT. Five tidal volumes (6, 8, 10, 12, and 14 mL/kg) were randomly tested, and respiratory rates were adjusted to achieve a minute ventilation of 100 mL/kg/min. The dose of propofol necessary to insert the SGAD or ETT, the static respiratory pressure, leakage during VCV, and end tidal CO2 (ETCO2) were recorded. Dosages of propofol and static respiratory measurements for the SGAD and ETT groups were compared using a t-test. The distribution of leakages and hypercapnia (ETCO2 > 45 mmHg) were compared using Fisher's exact test. A significance level of p < 0.05 was established. No significant difference in dose of propofol was observed between the SGAD and ETT groups (7.1 ± 1.0, 7.3 ± 1.7 mg/kg; p = 0.55). Static resistance pressure of the SGAD (22.0 ± 8.1 cmH2O/L/sec) was significantly lower than that of the ETT (36.6 ± 12.9 cmH2O/L/sec; p < 0.01). Of the 75 trials, leakage was more frequent when using an SGAD (8 events) than when using an ETT (1 event; p = 0.03). Hypercapnia occurred more frequently with SGAD (18 events) than with ETT (3 events; p < 0.01). Although intubation with an ETT is the gold standard in small animal anesthesia, the use of an SGAD can reduce airway resistance and the work of breathing. Nonetheless, SGAD had more dead space and the tidal volume for VCV needs adjustment.

Local Investigation and Magnetoresistance Properties of Co-Fe/Al-N/Co-Fe Tunnel Junctions Nitrided by Microwave-excited Plasma (질화법으로 제작한 강자성 터널링 접합의 국소전도 및 자기저항 특성)

  • Yoon Tae Sick;Tsunoda Masakiyo;Takahashi Migaku;Park Bum Chan;Lee Young-Woo;Li Ying;Kim Chong Oh
    • Korean Journal of Materials Research
    • /
    • v.14 no.3
    • /
    • pp.191-195
    • /
    • 2004
  • Tunnel junctions with AI-N barriers fabricated by microwave-excited plasma were studied. When the Al thickness, nitridation time, and annealing temperature were 1 nm (0.8 nm), 50 s (35 s), and $280^{\circ}C$ ($300^{\circ}C$), TMR ratio and resistance-area product (RA) were 49% (34%) and $3 ${\times}$ 10^4$ $\Omega$$\mu\m^2$ ($1.5 ${\times}$ 10^4$ $\Omega$$\mu\m^2$), respectively. In order to clarify the annealing temperature dependence of TMR ratio, the local transport properties were measured for Ta 5 nm/Cu 20 nm/Ta 5 nm$29_{76}$ $Fe_{24}$ 2 nm/Cu 5 nm/M $n_{75}$$Ir_{25}$ 10 nm/ $Co_{71}$ $Co_{29}$ 4nm/Al-N junction with Al thickness of 0.8 nm and nitridation time of 35s at various temperatures. The increase of TMR ratio after annealing at $300^{\circ}C$, where the TMR ratio of the corresponding MTJ had the maximum value of 34%, can be well explained by the enhancement of the average barrier height ($\Phi_{ave}$) and the reduction of its fluctuation. After further annealing at $340^{\circ}C$, the leakage current was observed and the TMR ratio decreaseded

Preparation and Oxygen Permeability of Nb-doped BCFN Ceramic Membrane (Nb-doped BCFN 세라믹 막의 제조 및 산소투과 특성)

  • Kim, Jong-Pyo;Son, Sou-Hwan;Park, Jung-Hoon;Lee, Yong-Taek
    • Membrane Journal
    • /
    • v.21 no.1
    • /
    • pp.55-61
    • /
    • 2011
  • $BaCo_{0.7}Fe_{0.22}Nb_{0.08}O_{3-{\delta}}$ oxide was synthesized by solid state reaction method. Dense ceramic membrane was prepared using as-prepared powder by pressing and sintering at $1,200^{\circ}C$. XRD result of membrane showed single perovskite structure. Leakage and oxygen permeation test were conducted on the membrane sealed by glass ring as a sealing material. The oxygen permeation flux increased with increasing temperature and pressure difference and maximum oxygen permeation flux was $2.3mL/min{\cdot}cm^2$ at $950^{\circ}C$ with $Po_2$ = 0.63 atm of oxygen partial pressure. The oxygen permeation in the condition of air with $CO_2$ (300 ppm) as feed stream decreased as much as only maximum 2.9% in comparison with air feed stream. It indicated $BaCo_{0.7}Fe_{0.22}Nb_{0.08}O_{3-{\delta}}$ membrane is more stable than another membrane for carbon dioxide.

Clamping Voltage Characteristics of ZPCCE-Based Varistors with Sintering Temperature (소결온도에 따른 ZPCCE계 바리스터의 제한전압특성)

  • 남춘우;박종아;김명준;유대훈
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.8
    • /
    • pp.835-839
    • /
    • 2004
  • The surge characteristics of ZnO varistors consisting of $ZnO-{Pr}_6{O}_11-CoO-{Cr}_2{O}_3-{Er}_2{O}_3$ceramics were investigated at various sintering temperatures. As sintering temperature raises, the varistor voltage was decreased from 341.2 to 223.1 V/mm, the nonlinear exponent was decreased from 64,9 to 44.1. On the other hand, the leakage current exhibited a minimum(0.64 $\mu$A) at 134$0^{\circ}C$, The clamping capability was slightly deteriorated with increasing sintering temperature. On the whole, the ZPCCE-based ZnO varistors exhibited good clamping voltage characteristics as exhibiting the clamping voltage ratio of 1.85 ∼ 1.92 approximately at surge current of 100 A.

Assessment of CO2 Geological Storage Capacity for Basalt Flow Structure around PZ-1 Exploration Well in the Southern Continental Shelf of Korea (남해 대륙붕 PZ-1 시추공 주변 현무암 대지 구조의 CO2 지중저장용량 평가)

  • Shin, Seung Yong;Kang, Moohee;Shinn, Young Jae;Cheong, Snons
    • Economic and Environmental Geology
    • /
    • v.53 no.1
    • /
    • pp.33-43
    • /
    • 2020
  • CO2 geological storage is currently considered as the most stable and effective technology for greenhouse gas reduction. The saline formations for CO2 geological storage are generally located at a depth of more than 800 m where CO2 can be stored in a supercritical state, and an extensive impermeable cap rock that prevents CO2 leakage to the surface should be distributed above the saline formations. Trough analysis of seismic and well data, we identified the basalt flow structure for potential CO2 storage where saline formation is overlain by basalt cap rock around PZ-1 exploration well in the Southern Continental Shelf of Korea. To evaluate CO2 storage capacity of the saline formation, total porosity and CO2 density are calculated based on well logging data of PZ-1 well. We constructed a 3D geological grid model with a certain size in the x, y and z axis directions for volume estimates of the saline formation, and performed a property modeling to assign total porosity to the geological grid. The estimated average CO2 geological storage capacity evaluated by the U.S. DOE method for the saline formation covered by the basalt cap rock is 84.17 Mt of CO2(ranges from 42.07 to 143.79 Mt of CO2).