• Title/Summary/Keyword: $CO_2$ leakage

Search Result 381, Processing Time 0.036 seconds

Structure of Edge Flame in a Methane-Oxygen Mixing Layer (메탄/순산소 혼합층에서 Edge Flame의 구조)

  • Choi, S.K.;Kim, J.;Chung, S.H.;Kim, J.S.
    • Journal of the Korean Society of Combustion
    • /
    • v.11 no.1
    • /
    • pp.19-26
    • /
    • 2006
  • Structure of edge flame established in a mixing layer, formed between two uniformly flowing pure $CH_4$ and pure $O_2$ streams, is numerically investigated by employing a detailed methane-oxidation mechanism. The numerical results exhibited the most outstanding distinction of using pure oxygen in the fuel-rich premixed-flame front, through which the carbon-containing compound is found to leak mainly in the form of CO instead of HC compounds, contrary to the rich $CH_4-air$ premixed flames in which $CH_4$ as well as $C_2H_m$ leakage can occur. Moreover, while passing through the rich premixed flame, a major route for CO production, in addition to the direct $CH_4$ decomposition, is found to be $C_2H_m$ compound formation followed by their decomposition into CO. Beyond the rich premixed flame front, CO is further oxidized into $CO_2$ in a broad diffusion-flame-like reaction zone located around moderately fuel-rich side of the stoichiometric mixture by the OH radical from the fuel-lean premixed-flame front. Since the secondary CO production through $C_2H_m$ decomposition has a relatively strong reaction intensity, an additional heat-release branch appears and the resulting heat-release profile can no longer be seen as a tribrachial structure.

  • PDF

Sequential optimization for pressure management in water distribution networks

  • Malvin S. Marlim;Doosun Kang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.169-169
    • /
    • 2023
  • Most distributed water is not used effectively due to water loss occurring in pipe networks. These water losses are caused by leakage, typically due to high water pressure to ensure adequate water supply. High water pressure can cause the pipe to burst or develop leaks over time, particularly in an aging network. In order to reduce the amount of leakage and ensure proper water distribution, it is important to apply pressure management. Pressure management aims to maintain a steady and uniform pressure level throughout the network, which can be achieved through various operational schemes. The schemes include: (1) installing a variable speed pump (VSP), (2) introducing district metered area (DMA), and (3) operating pressure-reducing valves (PRV). Applying these approaches requires consideration of various hydraulic, economic, and environmental aspects. Due to the different functions of these approaches and related components, an all-together optimization of these schemes is a complicated task. In order to reduce the optimization complexity, this study recommends a sequential optimization method. With three network operation schemes considered (i.e., VSP, DMA, and PRV), the method explores all the possible combinations of pressure management paths. Through sequential optimization, the best pressure management path can be determined using a multiple-criteria decision analysis (MCDA) to weigh in factors of cost savings, investment, pressure uniformity, and CO2 emissions. Additionally, the contribution of each scheme to pressure management was also described in the application results.

  • PDF

Microstructure, Electrical Properties, and Stability of ZPCCE Based Varistors (ZPCCE계 바리스터의 미세구조와 전기적 성질 및 안정성)

  • 남춘우;윤한수;류정선
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.9
    • /
    • pp.735-744
    • /
    • 2000
  • The electrical procerties and stability of ZnO-Pr$_{6}$O$_{11}$-CoO-Cr$_2$O$_3$-Er$_2$O$_3$ (ZPCCE) based varistors were investigated in the Er$_2$O$_3$content range of 0.0 to 4.0 mol%. ZPCCE ceramics containing 2.0 mol% Er$_2$O$_3$ exhibited the highest density of 5.74 g/㎤ corresponding to 99.3% of theoretical density. The varistors with 0.5 mol% and 2.0 mol% Er$_2$O$_3$exhibited a relatively satisfying nonlinearity, which the nonlinear exponent is 40.50 and 47.15, respectively and the leakage current is 2.66 $mutextrm{A}$, respectively. Under more severe d.c. stress, such as (0.80 V$_{1mA}$/9$0^{\circ}C$/12h)+(0.85 V$_{1mA}$115$^{\circ}C$/12h)+(0.90 V$_{1mA}$12$0^{\circ}C$/12h)+(0.95 V$_{1mA}$1$25^{\circ}C$12h), they showed a very excellent stability, which the variation rate of the variator voltage is -0.89% and -0.15%, the variation rate of the nonlinear coefficient is -4.67% and -3.56%, and the variation rate of leakage current is -6.02% and -19.56%, respectively. It is surely bellived that ZnO-0.5 mol% Pr$_{6}$O$_{11}$-1.0 mol% CoO-0.5 mol% Cr$_2$O$_3$-x mol% Er$_2$O$_3$(x=0.5, 2.0) based varistors will be greatly contributed to develop the advanced Pr$_{6}$O$_{11}$-based ZnO varistors in future.uture. future.uture.

  • PDF

A study on the characteristics for temporary ventilation of long subsea tunnels - focused on the current situation and improvement requirements (초장대 해저터널의 공사중 환기 특성에 관한 기초연구 - 현황 및 개선필요사항 중심)

  • Jo, Hyeong-Je;Chun, Kyu-Myung;Kim, Jong-Won;Lee, Ju-Kyung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.2
    • /
    • pp.153-166
    • /
    • 2015
  • Long subsea tunnel to be built below the seabed, as compared to the general railway tunnel, is subject to many restrictions in terms of spatial limitation when vertical or inclined shafts are built for the purpose of ventilation and fire safety. So, the construction of some artificial island is required to provide ventilation. But, because of construction difficulty and cost increase, it is necessary to minimize the artificial island construction. The longer ventilation distance is, the more fresh air requirement is needed. When supply airflow becomes excessive, duct size is restricted by the limitations of structure clearance and fan pressure and power increase exponentially. Therefore, in order to build a long subsea tunnel, it is necessary to overcome these practical problems and to develop technical solution that can keep the comfortable condition of tunnel environment during construction. In this study, as on ventilation method development suitable for long subsea tunnel, through comparison of temporary ventilation capacity calculation methods during construction phase, domestic and abroad, the application of Swiss SIA 196 code is found suitable for long subsea tunnel. And, through experiment on leakage of the duct connector, we confirmed that the leakage ratio per 100 m of domestic duct connection type is between 1.5~3.0%. Based on S-class duct of SIA 196 code, ventilation distance is 10.2 km, So, ventilation distance can be longer if duct connection method is improved. So, we confirmed that the improvement of leakage ratio is key issue in the construction-phase ventilation of long subsea tunnel.

Dust Collection Efficiency, Inhalation Pressure, and CO2 Concentration in Health Masks (보건용 마스크의 분진포집효율, 흡기저항 및 CO2 농도)

  • Han, Don-Hee;Kim, Il Soon
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.1
    • /
    • pp.78-87
    • /
    • 2020
  • Objectives: To identify the degree of physical burden, a determination was undertaken of dust collection efficiency, inhalation pressure, and CO2 concentration related to health masks certified by the Ministry of Food and Drug Safety (MFDS). Methods: Twenty health masks were purchased on the market. Dust collection efficiency and inhalation pressure were determined in the same manner as in MFDS certification testing, respectively using TSI Model 8130 (TSI, U.S.) and ART Plus (Korea). CO2 concentrations for 20 subjects using a CO2 analyzer (G100, G150, Geotechnical Instrument Ltd., UK) were measured with a similar method as a total inward leakage test. In addition to CO2 levels, dead space volumes in the masks was determined for predicting concentrations of CO2 in inhalation air. Results: Most of the dust collection efficiencies found for the 20 masks were far higher than the standard. Four KF94s met KF99 and four KF80s even met KF94. Most inhalation pressures were also much lower than the standard, with many almost one-half of the standard. The mean and standard deviation of CO2 concentration in the mask were 2.9±0.44%. Considering dead volume, the prediction for CO2 concentration in the inhalation air was 4,395±1,266 ppm. Conclusions: For healthy men and women, the dust collection efficiency and inhalation pressure of health masks were not at a level that would affect their health. Although CO2 levels in the inhalation air were predicted not to affect health, research on the physiological effects of health masks on Koreans is needed for more precise research.

A COMPARISON OF THE APICAL SEAL PRODUCED BY EASY FILLING SYSTEM AND QUICK OBTURATION SYSTEM (Easy Filling 및 Quick Obturation System을 이용한 열연화 충전법의 치근단 밀폐도 평가)

  • Shin, Jung-In;Kum, Kee-Yeon;Lee, Sung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.2
    • /
    • pp.202-211
    • /
    • 2000
  • The aim of this study was to compare the apical sealing ability of a new thermoplasticized gutta-percha filling technique, the Easy Filling and the Quick Obturation system with lateral condensation technique and Thermafil system to evaluate their clinical acceptabilities. Fifty-two extracted single-rooted teeth were instrumented to #35 using the .04 taper ProFile system. Four groups of 12 teeth were obturated by lateral condensation technique. Thermafil system and two new thermoplasticized gutta-percha techniques, the Easy Filling system and Quick Obturation system (Meta Dental co. Ltd. Korea), respectively. Four teeth served as controls. After the teeth were immersed in 2% methylene blue dye for 48 hours, they were resected horizontally at 1mm to 5mm level from the anatomical apex using a low-speed microtome. Each section was examined under a stereomicroscope at ${\times40}$ magnification and photographed. After each image was scanned, the leakage area was measured at each level using Brain 3 (Nosdia Tech., Korea) software. Leakage ratio was calculated for each group and was analyzed statistically to come up with the following results: 1. At 1mm level, the Quick Obturation system had the largest amount of apical leakage and it was statistically significant when compared with the lateral condensation group and the Thermafil group (p<0.05). 2. At 2mm and 3mm level, there were no significant difference of apical leakage among all four groups (p>0.05), and from 4mm level, no apical dye penetration was observed in all the groups. In conclusion, the apical seal produced by Easy Filling system and the Quick Obturation system was comparable to lateral condensation technique and Thermafil system except for the 1mm level. More improvement of the apical seal can be expected as the operator becomes skillful with the new techniques.

  • PDF

중수로 환형기체 계통의 방사능 inventory 평가

  • Kim, Jin-Tae;Kang, Deok-Won;Son, Uk
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.90-95
    • /
    • 2003
  • Chemical management of annulus gas system is carried out for the purpose of ensuring the safety and reliability of the system via securing the integrity of the system, detecting the D$_2$O in-leakage of coolant and/or moderator, and reducing the radiation dose. Since the quality of CO_2$ gas, which is used as a filling gas for annulus gas system at CANDU plants, has a propound effect on the integrity of the system material and the radiation dose, CO_2$ gas of high quality is needed. If the quality of CO_2$ gas does not meet the specification, it may give rise to undesirable effect not only on the annulus gas system, but also on the environment due to the production of radioactive nuclei. Therefore, it is very important to check the impurities of CO_2$ gas. Based on this background, the inventories of C-14 and Ar-41 in CO_2$ gas that is supplied as annulus gas were estimated using the data on concentrations of the impurities of $CO_2$ such as C, N_2$ and Ar. The results of this study is expect to give useful information on optimization of CO_2$ impurities maintenance and management of gaseous radioactive wastes produced at CANDU plants.

  • PDF

Influence of Sintering Temperature on Electrical and Dielectric Characteristics of Zn-Pr-Co-Cr-La Oxide-Based Nonlinear Resistors (Zn-Pr-Co-Cr-La 산화물계 비선형 저항체의 전기적, 유전적 성질에 소결온도가 미치는 영향)

  • Nahm, Choon-Woo
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.9 s.292
    • /
    • pp.558-563
    • /
    • 2006
  • The electrical and dielectric properties of $ZnO-Pr_6O_{11}CoO-Cr_2O_3La_2O_3-based$ nonlinear resistors were investigated at different sintering temperatures in the range of $1230{\sim}1300^{|circ}C$. As the sintering temperature increased, the breakdown voltage decreased from 777.9 to 108.0V/mm, the nonlinear coefficient greatly decreased from 77.0 to 7.1, and the leakage current increased from $0.4{\mu}A\;to\;50.6{\mu}A$. On the other hand, the donor density from $0.90{\times}10^{18}\;to\;2.59{\times}10^{18}/cm^3$ and the barrier height decreased from 1.89 to 0.69 eV with increasing temperature. The dielectric dissipation factor increased from 0.0879 to 0.2839 for the increase of sintering temperature.

A STUDY ON THE MARGINAL LEAKAGE OF RESTORATIONS WITH DIFFERENT CAVOSURFACE MARGINS (와연형태(窩緣形態)에 따른 와연누출(邊緣漏出)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Shin, Han-Ju;Choi, Ho-Young;Min, Byung-Soon;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.12 no.1
    • /
    • pp.119-129
    • /
    • 1986
  • The purpose of this study was to evaluate the marginal leakage of glass ionomer cement with different cavosurface margins. 192 class V cavities were prepared on freshly extracted non-carious teeth and glass ionomer cement were inserted according to the manufacturer's instructions. Cavity preparations for this investigation were performed in four groups. The experimental specimens were made by packing the glass ionomer cement (Fuji Ionomer Type II G-C Co. Japan) into the prepared 192 cavities of four groups with different modes: Group I. - The 48 cavities with $90^{\circ}$ butt-joint cavosurface preparation and restored with glass ionomer cement. Group II. - The 48 cavities with butt-joint preparation modified by $135^{\circ}$ beveling the cavosurface in the dentin and restored with glass ionomer cement. Group III. - The 48 cavities with butt-joint preparation modified by cutting a chamfer in the dentin and restored with glass ionomer cement. Group IV. - The same 48 cavities as group I, and overfilled with glass ionomer cement beyond the cavosurface angle. And four groups above described divided into three subgroups by means of conditioning the cavity walls: Control group. - Glass ionomer cement filled in the prepared 64 cavities after being cleaned with a stream of tap water. Phosphoric acid treatment group. - Glass ionomer cement filled in the prepared 64 cavities after being conditioned with a 50% phosphoric acid. Citric acid treatment group. - Glass ionomer cement filled in the prepared 64 cavities after being conditioned with a 50% citric acid. All 192 specimens were immersed in the 2.0% basic fuchsin solution and subjected to thermal stress at one-minute intervals ($4{\pm}2^{\circ}C$ to $60{\pm}2^{\circ}C$) for 70 minutes before exposure to the dye. The specimens were sectioned ecclesiologically through the center of the restorations for different periods of immersion time, 24 hours, 7 days, 14 days 30 days. The sections were examined under a stereoscopic microscope. The results were as follows: 1. The degree of marginal leakage in group II and III was greater than that in group I and IV. 2. The degree of marginal leakage in phosphoric acid treatment group was similar with that in control group. 3. The degree of marginal leakage in citric acid treatment group was less than that in control group. 4. In all groups, the degree of marginal leakage in phosphoric acid treatment group was greater than that in citric acid treatment group. 5. There is no statistical difference of the degree of marginal leakage according to the immersion time in the dye solution.

  • PDF

Highly Robust Bendable a-IGZO TFTs on Polyimide Substrate with New Structure

  • Kim, Tae-Woong;Stryakhilev, Denis;Jin, Dong-Un;Lee, Jae-Seob;An, Sung-Guk;Kim, Hyung-Sik;Kim, Young-Gu;Pyo, Young-Shin;Seo, Sang-Joon;Kang, Kin-Yeng;Chung, Ho-Kyoon;Berkeley, Brain;Kim, Sang-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.998-1001
    • /
    • 2009
  • A new flexible TFT backplane structure with improved mechanical reliability is proposed. Amorphous indium-gallium-zinc-oxide (a-IGZO) thin film transistors based on this structure have been fabricated on a polyimide substrate, and the resultant mechanical durability has been evaluated in a cyclic bending test. The panel can withstand 10,000 bending cycles at a bending radius of 5 mm without any noticeable TFT degradation. After 10K bending cycles, the change of threshold voltage, mobility, sub-threshold slope, and gate leakage current were only -0.22V, -0.13$cm^2$/V-s, -0.05V/decade, and $-3.05{\times}10^{-13}A$, respectively.

  • PDF