• Title/Summary/Keyword: $CO_2$ Removal

Search Result 1,172, Processing Time 0.023 seconds

Smoke Control According to the Ventilation Capacity in Subway Tunnel Fire: I. FDS Simulation (지하철 터널 화재시 환기시설의 용량에 따른 제연효과 I. FDS 시뮬레이션)

  • Park, Kyung-Jun;Lee, Ki-Jun;Hadi, Bettar El;Lee, Jai-Hyo;Shin, Dong-Il
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.3
    • /
    • pp.31-38
    • /
    • 2011
  • In this study, we investigate simulation studies to confirm the removal of smoke through ventilation when the subway car is on fire and stopped in an underground subway tunnel, by using Fire Dynamics Simulator (FDS) which is being upgraded by NIST. The structure of subway tunnel and train for simulation modeling are based actual data from Seoul metropolitan subway. The main purpose of this study is to assure the removal efficiency of the ventilation when changing the ventilation capacity between 2.0 m/s and 3.0 m/s. The results of the study shows that carbon monoxide (CO) and carbon dioxide ($CO_2$) are reduced by about 35% as the ventilation capacity is increased by 0.5 m/s. This study also performs the grid sensitivity verification of FDS for improved accuracy of the results. To find the effective size of the grid, three cases are simulated and the results are compared.

Multi-stage Process Study of PEI-PDMS Hollow Fiber Composite Membrane Modules for $H_2/CO_2$ Mixed Gas Separation ($H_2/CO_2$ 혼합기체의 분리를 위한 PEI-PDMS 중공사 복합막 모듈의 다단 공정 연구)

  • Lee, Chung Seop;Cho, Eun Hye;Ha, Seong Yong;Chung, Jong Tae;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.23 no.1
    • /
    • pp.1-11
    • /
    • 2013
  • Poly(ether imide) (PEI)-poly(dimethylsioxane) (PDMS) composite membranes and their modules were prepared, which are capable of selective $CO_2$ separation from the mixture gas. The gas flow rate, concentration, recovery ratio of $H_2$ and removal ratio of $CO_2$ outflowing by stage-cut were characterized at $25^{\circ}C$ and the constant pressure. In addition, to increase the recovery ratio of $H_2$, one stage, two stage series connection, and three stages series + parallel connection tests were carried out. When the stage-cut was 0.32 for the three stages connection operation, the concentration $H_2$ of the produced gas and the recovery ratio of $H_2$ was 97% and 85%, respectively. And also the removal ratio of $CO_2$ was 90% was obtained and the recycled gas concentration was similar with that of the feed gases.

Characterization of Algal-Bacterial Ecological Interaction and Nutrients Removal Under Municipal Wastewater Condition (실제 하수조건에서 조류-세균 복합군집의 생태적 상호작용 및 영양염류 제거 특성 규명)

  • Lee, Jang-Ho;Park, Joon-Hong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.5
    • /
    • pp.314-324
    • /
    • 2011
  • Algal biomass cultivated by wastewater is potentially useful resource for biodiesel production. However, little is known about algal nutrient metabolism and microbial interaction with bacteria under real municipal wastewater condition. In this work, we characterized nitrogen and phosphorus removals of municipal wastewater by a representative wastewater-growing algal population. Ankistrodesmus gracilis SAG 278-2, and analyzed its ecological interaction with wastewater bacterial communities. Compared to wastewater sludge itself, algal-bacterial co-culture improved nutrient removal. According to bacterial community analysis with 16S rRNA genes, a selective and dominant growth of a Unclassified Alcaligenaceae population resulted from algal growth in the algal-bacterial co-culture. The selectively stimulated bacterial population is phylogenetically close to Alcaligenes faecalis subsp. 5659-H, which is known to be co-present interact with algae in aquatic environment. These findings suggest that algal growth/metabolism may have effects on selection of a specific bacterial population in algal-bacterial co-cultures that can efficiently remove nutrients from municipal wastewater.

A Separation of manganese (II) and cobalt (II) ions by D2EHPA/TBP-immobilized PolyHIPE membrane

  • Chen, Jyh-Herng;Mai, Le Thi Tuyet
    • Membrane and Water Treatment
    • /
    • v.10 no.2
    • /
    • pp.127-137
    • /
    • 2019
  • The D2EHPA/TBP co-extractants immobilized PolyHIPE membrane can be used for the selective separation of Mn (II) from Co (II). By solvent-nonsolvent method, D2EHPA/TBP co-extractants can be effectively immobilized into PolyHIPE membrane. The pore structure of PolyHIPE membrane and the presence of TBP enhance the stability of immobilized co-extractants. The optimal operating conditions for the separation of Mn (II) and Co (II) are feeding phase at pH 5.5, sulfuric acid concentration in the stripping phase of about 50 g/L and stirring speed at 400 rpm. The D2EHPA/TBP co-extractants ratio of 5:1 shows synergetic effect on Mn/Co separation factor about 22.74. The removal rate and recovery rate of Mn (II) is about 98.4 and 97.1%, respectively, while for Co (II) the transport efficiency is insignificant. The kinetic study of Mn (II) transport shows that high initial flux, $J_f^o=80.1({\mu}mol/m^2s)$, and maxima stripping flux, $J_s^{max}=20.8({\mu}mol/m^2s)$, can be achieved with D2EHPA/TBP co-extractants immobilized PolyHIPE membrane. The stability and reusability study shows that the membrane can maintain a long term performance with high efficiency. High purity of Co (II) and Mn (II) can be recovered from the feeding phase and stripping phase, respectively.

Photocatalytic Destruction of Chlorinated and Aromatic Hydrocarbons for Low-Level Indoor Air Cleaning (저농도 실내공기 정화를 위한 염소화 및 방향족 탄화수소의 광촉매 분해)

  • Jo, Wan Geun;Gwon, Gi Dong;Choe, Sang Jun;Song, Dong Ik
    • Journal of Environmental Science International
    • /
    • v.13 no.9
    • /
    • pp.767-777
    • /
    • 2004
  • This study evaluated the technical feasibility of the application of $TiO_2$ photocatalysis for the removal of volatile hydrocarbons(VHC) at low ppb concentrations commonly associated with non-occupational indoor air quality issues. A series of experiments was conducted to evaluate five parameters (relative humidity (RH), hydraulic diameter (HD), feeding type (FT) of VHC, photocatalytic oxidation (PCO) reactor material (RM), and inlet port size (IPS) of PCO reactor) for the PCO destruction efficiencies of the selected target VHC. None of the target VHC presented significant dependence on the RH, which are inconsistent with a certain previous study that reported that under conditions of low humidity and a ppm toluene inlet level, there was a drop in the PCO efficiency with decreasing humidity. However, it is noted that the four parameters (HD, RM, FT and IPS) should be considered for better VHC removal efficiencies for the application of $TiO_2$ photocatalytic technology for cleansing non-occupational indoor air. The PCO destruction of VHC at concentrations associated with non-occupational indoor air quality issues can be up to nearly 100%. The amount of CO generated during PCO were a negligible addition to the indoor CO levels. These abilities can make the PCO reactor an important tool in the effort to improve non-occupational indoor air quality.

Biological Removal of Nitrogen Oxides from Combustion Flue Gases (연소배가스 중 질소산화물(NOx) 제거를 위한 생물학적 기술)

  • Lee, Ki-Say
    • Applied Chemistry for Engineering
    • /
    • v.21 no.3
    • /
    • pp.243-251
    • /
    • 2010
  • Nitrogen oxides (NOx) in combustion flue gas are currently mitigated by chemical processes such as catalytic reduction, absorption and adsorption. However, development of environmentally sustainable biological processes is necessary in the near future. In this paper, the up-to-dated R&D trend of biological methodologies regarding NOx removal was reviewed, and their advantages and disadvantages were discussed. The principles and applications of bacterial system including nitrification and denitrification and photosynthetic microalgae system were compared. In order to enhance biological treatment rate and performance, the insoluble nitric oxide (NO) should be first absorbed using a proper solubilization agent, and then microbial degradation or fixation is to be followed. The use of microalgal system has a good prospect because it can fix $CO_2$ and NOx simultaneously and requires no additional carbon for energy source.

Performance Analysis of an Oxy-fuel Combustion Power Generation System Based on Waste Heat Recovery: Influence of CO2 Capture (배열회수형 순산소연소 발전시스템의 성능해석: CO2 포집의 영향)

  • Tak, Sang-Hyun;Park, Sung-Ku;Kim, Tong-Seop;Sohn, Jeong-Lak;Lee, Young-Duk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.12
    • /
    • pp.968-976
    • /
    • 2009
  • As the global warming becomes a serious environmental problem, studies of reducing $CO_2$ emission in power generation area are in progress all over the world. One of the carbon capture and storage(CCS) technologies is known as oxy-fuel combustion power generation system. In the oxy-fuel combustion system, the exhaust gas is mainly composed of $CO_2$ and $H_2O$. Thus, high-purity $CO_2$ can be obtained after a proper $H_2O$ removal process. In this paper, an oxy-fuel combustion cycle that recovers the waste heat of a high-temperature fuel cell is analyzed thermodynamically. Variations of characteristics of $CO_2$ and $H_2O$ mixture which is extracted from the condenser and power consumption required to obtain highly-pure $CO_2$ gas were examined according to the variation of the condensing pressure. The influence of the number of compression stages on the power consumption of the $CO_2$ capture process was analyzed, and the overall system performance was also investigated.

Characteristics of precipitation treatment for Ca and Mg pretreatment of brine generated from MD/RO desalination plant (MD/RO 담수화 플랜트에서 발생한 농축수의 Ca 및 Mg 전처리를 위한 침전 처리 특성)

  • Shim, Jae-Ho;Park, Jae-Chul;Lim, Dae-Hwan;Park, Joo-Yang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.4
    • /
    • pp.329-338
    • /
    • 2017
  • The problem of disposal of brine due to increased MD/RO desalination plant has recently become a big social issue. The chlor-alkali process through electrolysis of brine has been studied as a method to overcome this problem. In order to increase the electrolysis efficiency, a pretreatment process for removal of hard substances must be preceded. In this study, we investigated the mechanism of removal of hardness through chemical precipitation. As a result, Ca was greatly influenced by addition of $Na_2CO_3$, and Mg was strongly influenced by pH. Also, the addition of NaOH and $Na_2CO_3$ enabled simultaneous removal of Ca and Mg, and showed a removal efficiency of 99.9% or more. Finally, the residual concentrations of Ca and Mg in the brine after the reaction were 0.14 and 0.13 mg/L, respectively. Saturation index was calculated using Visual MINTEQ 3.1, and solid phase analysis of the precipitate was performed by FE-SEM and PXRD analysis. It was confirmed that precipitate formed by the formation of calcite and brucite.

Hydrogen Sulfide Removal by Immobilized Thiobacillus novellas on $SiO_2$ in a Fluidized Bed Reactor

  • Cha, Jin-Myung;Shin, Hyun-Jae;Roh, Sung-Hee;Kim, Sun-Il
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.2
    • /
    • pp.320-324
    • /
    • 2007
  • The removal of hydrogen sulfide ($H_2S$) from aqueous media was investigated using Thiobacillus novellas cells immobilized on a $SiO_2$ carrier (biosand). The optimal growth conditions for the bacterial strain were $30^{\circ}C$ and initial pH of 7.0. The main product of hydrogen sulfide oxidation by T. novellus was identified as the sulfate ion. A removal efficiency of 98% was maintained in the three-phase fluidized-bed reactor, whereas the efficiency was reduced to 90% for the two-phase fluidized-bed reactor and 68% for the two-phase reactor without cells. The maximum gas removal capacity for the system was 254 g $H_2S/m^3/h$ when the inlet $H_2S$ loading was $300g/m^3/h(1,500ppm)$. Stable operation of the immobilized reactor was possible for 20 days with the inlet $H_2S$ concentration held to 1,100 ppm. The fluidized bed bioreactor appeared to be an effective means for controlling hydrogen sulfide emissions.

Removal of NOx and $SO_2$ from Combustion Flue Gases by Corona Discharge Systems (코로나 방전 시스템을 이용한 연소가스중의 NOx, $SO_2$제거)

  • 박재윤
    • Electrical & Electronic Materials
    • /
    • v.10 no.8
    • /
    • pp.830-835
    • /
    • 1997
  • In this study an experimental investigation has been conducted to remove NOx and SO$_2$simultaneously from a combustion flue gases were consisted of NO-SO$_2$-$CO_2$-$N_2$-O$_2$([NO]o:200ppm and [SO$_2$]o:800ppm) and the injection gases used as radical source gases were NH$_3$-Ar-air and CH$_4$-Ar-air. NOx and SO$_2$removal efficiency and the other by-products were measured by Fourier Transform Infrared(FTIR) as well as SO$_2$, NOx and NO$_2$gas detectors. and SEM images after sampling. The results showed that a significant Nucleating Particle Counter(CNPC) and SEM images after sampling. The results showed that a significant aerosol particle formation was observed during a simultaneous NOx and SO$_2$removal operation in corona radical shower systems. The diameter of aerosol particles was in the range of 0.18 to 3.6${\mu}{\textrm}{m}$ with a maximum fraction of particles at particles diameter of 1${\mu}{\textrm}{m}$. The NOx removal efficiency significantly increased with increasing applied voltage and NH$_3$molecule ratio. The SO$_2$removal efficiency was not significantly effected by applied voltage and slightly increased with increasing NH$_3$molecule ratio. It could be found that it is possible to use CH$_4$for NOx and SO$_2$removal by corona radical shower systems.