• Title/Summary/Keyword: $CO_2$ LASER

Search Result 988, Processing Time 0.025 seconds

Development of TEA $CO_2$ Laser Excited by a Magnetic Switch Pulse Source (자기 스위치 펄스 전원을 이용한 TEA $CO_2$ 레이저 개발)

  • Hong, J.U.;Park, D.I.;Lee, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.657-659
    • /
    • 1993
  • We have developed a repetitive TEA $CO_2$ laser excited by a magnetic switch pulse source, and have measured the laser output energy for the mixing ratio of the laser gas mixture in single pulse. As a result of experiments, we have obtained the laser output energy of 252 mJ($\eta_{intrinsic}$=7.8%) in $CO_2:N_2$:He=1:1:8(1 atm.). At a repetition-rate frequency of 10 Hz, an average laser power of 1.5 W was obtained.

  • PDF

The Use of Locally Applied Vibration to Minimize Pain during Fractional CO2 Laser Therapy in Living Liver-Donor Scar Management

  • Song, Sinyoung;Choi, Dong Hoon;Oh, Tae Suk
    • Archives of Plastic Surgery
    • /
    • v.43 no.6
    • /
    • pp.570-574
    • /
    • 2016
  • Background Fractional $CO_2$ laser is an effective treatment for scars, but most patients complain about sharp burning pain, even after the application of lidocaine ointment. This study analyzed the impact of a vibrating device to nonpharmacologically reduce the acute pain of laser treatment, in accordance with the gate control theory of pain management. Methods This is a prospective study performed from May 2013 through March 2014. Fifty-three patients (mean age, 26.7 years; range, 16-44 years) who had donated livers for liver transplantation were treated with a fractional $CO_2$ laser (10,600 nm; model $eCO_2$, Lutronic Corp) for their abdomen scars. Laser treatment was applied 4 months after surgery. A commercially available, locally applied vibrating device (model UM-30M, Unix Electronics Co. Ltd.) was used, in an on-and-off pattern, together with the $CO_2$ laser. A visual analogue scale (VAS; 0, no pain; 10, most severe pain) of pain sensation was assessed and statistically analyzed using a paired t-test. Results The average VAS score for pain with the vibrating device was 4.60 and the average VAS score without the vibrating device was 6.11. The average difference between scores was 1.51 (P=0.001). Conclusions A locally applied vibrating device was demonstrated to be effective in reducing pain when treating with a fractional $CO_2$ laser. Vibration treatment could be helpful when treating scars with fractional $CO_2$ laser in pain-sensitive patients, particularly children.

Comparison of Wound Healing in Porcine Skin with Continuous-Wave and Pulsed Mode $CO_2$ Laser Incisions (돼지에서 연속형 $CO_2$ 레이저와 펄스형 $CO_2$ 레이저를 이용한 피부절개시 창상치유 평가)

  • Lee, Jae-Yeon;Cho, Sung-Whan;Park, Chang-Sik;Kim, Myung-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.27 no.6
    • /
    • pp.647-651
    • /
    • 2010
  • The advantages of the $CO_2$ laser are offset by the delay in laser wound healing secondary to thermal damage. To minimize the undesirable thermal damage of the $CO_2$ laser, investigators have developed technical advances in the delivery system of the laser energy. This study compared tissue healing of the continuous and the pulsed modes $CO_2$ laser wounds in an animal surgery model. Five healthy Landrace and Yorkshire mixed breeds of both genders were used (45-51 kg, 4-6 months old, three males and two females). A full thickness wound of skin ($2{\times}2{\times}2cm^2$) was made over on the each pig's both sides of dorsal midline at 0, 7, 14, and 18 days. The wounds created at 18, 14, 7 and 0 days were named post-wounding day (PWD) 3, 7, 14 and 21, respectively. In each pig, one wound (left side) was treated pulsed $CO_2$ laser and the other wound (right side) was treated continuous wave $CO_2$ laser. Each wound was closed with two interrupted suture of 3-0 sutures. At 21 days after initial wounding, each wound was taken for histological evaluations. The degrees of reepithelialization were performed more prominently in the pulsed mode group than in the continuous mode group. The degrees of granulation were greater significantly in pulsed mode group than those in the continuous mode on PWD 3 (p < 0.05). The degrees of fibroblasts in the pulsed mode group were greater significantly in comparison to those in the continuous mode group on PWD 7, (p < 0.05). In conclusion, reepithelialization, granulation and fibroblasts in the pulsed mode group were greater markedly in comparison to those in the continuous mode group. It was considered that pulsed mode $CO_2$ laser was more suitable for the skin incision than the continuous mode $CO_2$ laser.

Strengthening of Steel Sheets for Automobile by $CO_2$ Laser Beam Irradiation (자동차용 강판의 $CO_2$ 레이저 빔 조사 강화)

  • Seo, Jung;Lee, Je-Hoon;Kim, Jung-Oh;Oh, Sang-Jin;Cho, Won-Seok;Lee, Doo-Hwan;Shin, Chul-Soo
    • Laser Solutions
    • /
    • v.4 no.2
    • /
    • pp.21-28
    • /
    • 2001
  • The laser strengthening of 35kgf/㎟ and 60kgf/㎟ grade steel sheets is investigated by using CO$_2$ laser beam irradiation. The increase of tensile strength is dominated by the number of fully penetrated melting line. Also. the optimal laser input energy(hardness) and the number of melting line (melting width) are important variables for laser strengthening. Local strengthening by laser beam may be effective for the weight reduction of components where the tailored welded blank can not be applied.

  • PDF

Effects of Acid-etching, CO2 and Nd:YAG Lasing on the Dentin Surface (산부식과 CO2 및 Nd:YAG 레이저 조사에 따른 상아질 표면의 변화)

  • Lee, Jae-Hak;Park, June-Sang;Ko, Myung-Yun
    • Journal of Oral Medicine and Pain
    • /
    • v.25 no.1
    • /
    • pp.129-144
    • /
    • 2000
  • The purpose of this study was to examine dentin surface changes of extracted sound third molar specimens which were etched with 10% maleic acid and irradiated at $7-140J/cm^2$ with $CO_2$ and at $156-280J/cm^2$ with Nd:YAG laser. The results were as follows. 1. Dentin surfaces etched with 10% maleic acid and then irradiated at below of $42J/cm^2$ with $CO_2$ laser showed the retentive morphology for resin restoration. 2. Dentin surfaces irradiated at below of $42J/cm^2$ with $CO_2$ laser showed the increased acid-resistance. 3. Dentin surfaces irradiated at $218-280J/cm^2$ with Nd:YAG laser showed the retentive morphology. 4. Dentin surfaces irradiated at $218-280J/cm^2$ with Nd:YAG laser and etched 10% maleic acid and then $218-280J/cm^2$ with Nd:YAG laser showed the increased acid-resistance.

  • PDF

Treatment of Gingival Irritation Fibroma Using $CO_2$ Laser (이산화탄소 레이저($CO_2$ laser)를 이용한 치은에 발생한 자극성 섬유종의 치료)

  • Choi, Young-Chan;Park, Ju-Hyun;Ahn, Hyung-Joon
    • Journal of Oral Medicine and Pain
    • /
    • v.35 no.2
    • /
    • pp.119-122
    • /
    • 2010
  • Carbondioxide($CO_2$) laser is one of the most widely employed lasers in oral soft tissue surgery because of its excellent affinity for water based soft tissues. It has some inherent advantages such as hemostasis, less postoperative swelling, reduction of bacterial population at surgical site, less need for suturing, less scarring, and less postoperative pain compared to conventional surgical therapies including the use of scalpel, diathermy, cryotherapy and electrosurgery. A 30-years-old male was presented with gingival swelling. Clinical examination revealed a well?defined pedunculated fibrotic mass on the buccal gingiva near right maxillary 1st molar. In radiographic examination, no remarkable abnormality was seen. Excisional biopsy was performed with $CO_2$ laser (continuous wave mode, 4.0W). Histological diagnosis was "Irritation fibroma". $CO_2$ laser has advantages those are suitable for surgical treatment of intraoral lesion. If appropriate training and experience are provided, the dentist would be able to manage intraoral lesions more efficiently and successfully with the use of the $CO_2$ laser.

Characteristics of $CO_2$ Laser Cladding with High Viscosity Mixed Powder (용제와 혼합한 금속분말의 $CO_2$ 레이저 클래딩 특성)

  • 김재도;전병철;이영곤;오동수
    • Journal of Welding and Joining
    • /
    • v.19 no.5
    • /
    • pp.481-485
    • /
    • 2001
  • Laser cladding processing allows rapid transfer of heat to the material being processed with minimum conduction into base metal. The effect of $CO_2$ laser cladding with high viscosity mixed powders was investigated. High viscosity mixed powder consists of bronze powder and flux that is used at a high temperature condition. The mixed powder has a high viscosity that it can be easily pasted over a curved or slope substrate. The device for mixed powder was designed and manufactured. It consists of the high viscosity mixed powder feeding system, the preheating system and the shielding gas system which prevents the clad layer from being oxidized. The results of experiment indicated that the feed rate of high viscosity mixed powder was important for later cladding with mixed powder feeding. The high viscosity mixed powder and substrate must be preheated to prevent porosity from breaking at the clad layer. The experimental result shows that the high viscosity mixed can be applied for laser cladding process.

  • PDF

Fabrication of Breathable Film using Laser Pulses (레이저를 이용한 숨쉬는 필름 가공 기술 연구)

  • Choi, Hun Kook;Sohn, Ik Bu;Noh, Young Chul;Choi, Young Jin;Chang, In Gu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.4
    • /
    • pp.409-413
    • /
    • 2013
  • A polypropylene film was ablated using a $CO_2$ laser, Ti-sapphire femtosecond laser, and UV nanosecond laser. For modified atmosphere packaging, polypropylene films were ablated by laser pulse with different pulse energies and measured on an optical microscope. Also, we observed the shelf life of a banana contained within packaging of a breathable zipper bag. As a result, we have demonstrated that the breathable film can efficiently extend the shelf life of respiring foods, particularly fresh fruits and vegetables. The development of breathable film laser microfabrication system will more useful for industrial applications.

Characteristic of Laser Cladding Process with High Viscosity Bronze Powder and Al-alloy (고점성 청동분말을 이용한 알루미늄 합금의 레이저 클래딩 특성)

  • 오동수;전병철;김재도
    • Proceedings of the Korean Society of Laser Processing Conference
    • /
    • 2001.05a
    • /
    • pp.31-34
    • /
    • 2001
  • Laser cladding Processing allows rapid transfer of heat to the material being minimum conduction into base metal. The effects of CO$_2$ laser cladding with high powder were investigated. High viscosity bronze powder consists of bronze powder used at a high temperature. The material has a high viscosity So that it can be substrate. Therefore. Laser cladding can be processed on a curved or slope surface. CO$_2$ laser cladding was designed It consists of the high viscosity bronze powder the shielding gas system and the preheating system The high viscosity powder properly at 0.3g/s and 0.50g/s. Because of the metallic bond between bronze per the hardness of dilution layer was suddenly increased. Experimental as results viscosity mixed powder can be a useful cladding material.

  • PDF

Bond strength of resin cement to $CO_2$ and Er:YAG laser-treated zirconia ceramic

  • Kasraei, Shahin;Rezaei-Soufi, Loghman;Heidari, Bijan;Vafaee, Fariborz
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.4
    • /
    • pp.296-302
    • /
    • 2014
  • Objectives: It is difficult to achieve adhesion between resin cement and zirconia ceramics using routine surface preparation methods. The aim of this study was to evaluate the effects of $CO_2$ and Er:YAG laser treatment on the bond strength of resin cement to zirconia ceramics. Materials and Methods: In this in-vitro study 45 zirconia disks (6 mm in diameter and 2 mm in thickness) were assigned to 3 groups (n = 15). In control group (CNT) no laser treatment was used. In groups COL and EYL, $CO_2$ and Er:YAG lasers were used for pretreatment of zirconia surface, respectively. Composite resin disks were cemented on zirconia disk using dual-curing resin cement. Shear bond strength tests were performed at a crosshead speed of 0.5 mm/min after 24 hr distilled water storage. Data were analyzed by one-way ANOVA and post hoc Tukey's HSD tests. Results: The means and standard deviations of shear bond strength values in the EYL, COL and CNT groups were $8.65{\pm}1.75$, $12.12{\pm}3.02$, and $5.97{\pm}1.14MPa$, respectively. Data showed that application of $CO_2$ and Er:YAG lasers resulted in a significant higher shear bond strength of resin cement to zirconia ceramics (p < 0.0001). The highest bond strength was recorded in the COL group (p < 0.0001). In the CNT group all the failures were adhesive. However, in the laser groups, 80% of the failures were of the adhesive type. Conclusions: Pretreatment of zirconia ceramic via $CO_2$ and Er:YAG laser improves the bond strength of resin cement to zirconia ceramic, with higher bond strength values in the $CO_2$ laser treated samples.