• 제목/요약/키워드: $CO_2$ LASER

검색결과 988건 처리시간 0.031초

레이저 용접의 비드 형상에 대한 실험치와 이론 결과의 비교 (Comparison of Theoretical model with Experiment in Bead Shape of Laser Welding)

  • Kim, J.D.;Kim, J.D.
    • 한국정밀공학회지
    • /
    • 제11권1호
    • /
    • pp.201-210
    • /
    • 1994
  • A theoretical heat-flow model incorporating with a constant moving CO$_{2}$ laser beam has been analyzed to predict depth and the shape of bead section during last beam welding. The laser beam is exponentially attenuated with an abosrption coefficient in the material. The solution can be expressed in terms of normalized variables. The experimental data were generated by usint CW 2 CO$_{2}$ laser with multi beam mode and CW 3 kW CO$_{2}$laser with Gaussian mode. The specimens were made as bead-on-plate welds for SM 10C, STS 304, STS 316, STS 420 and pure Nickel. The maximum possible penetration depth and the shape of beas section for given sources of laser power, travel speed and beam spot size can be prdicted with this model in a given material.

  • PDF

자동차 부품의 원격 레이저 용접기술 (Remote Welding of Automobile Components using CO2 Laser and Scanner)

  • 서정;이문용;정병훈;송문종;강희신;김정오
    • Journal of Welding and Joining
    • /
    • 제26권5호
    • /
    • pp.74-78
    • /
    • 2008
  • The laser welding of the car body and components has been spread in the automotive industry. The Nd:YAG laser welding system could be used in 3D welding with robot. However, this system cannot efficiently reduce the welding cycle time according to various welding sequences because the robot's moving time is same that of the resistant spot welding system. But the remote welding system with high power $CO_2$ laser and scanner makes it possible welding cycle time much faster than the robot laser welding system. In the $CO_2$ laser remote welding system, laser beam can be rapidly transferred to a workpiece by moving mirrors of scanner system. So, it makes reducing the cycle time of welding process and shaping various welding patterns easily. Therefore, in this paper, the characteristic of weld strength according to patterns of weld bead on $CO_2$ laser welding was investigated. Also, the relationship between shape of weld bead and value of tensile load was studied. Finally, the optimum remote welding condition for car bumper was investigated.

$CO_2$ 레이저를 이용한 시료 표면의 국부 폴리싱 (The local polishing of material surface using the $CO_2$ laser)

  • 김영섭;손익부;노영철
    • 한국레이저가공학회지
    • /
    • 제12권2호
    • /
    • pp.7-10
    • /
    • 2009
  • In this paper, we study experimentally the local polishing of $SiO_2$ surface using the $CO_2$ laser. For laser local polishing, we polished to remove the grooves or to be reformed the surface of grooves after forming the grooves on the material surface. We measured the reflectance, transmittance, and beam profile in order to measure the roughness of polished surface. The Atom Force Microscope (AFM) is used to measure roughness of local polishing surface. We can predict that the laser polishing contribute to the removal of generated debris and surface roughness on the micro processing.

  • PDF

레이저 후두미세수술의 원칙 (Principles of Laser Laryngeal Microsurgery)

  • 문정환;이상준;정필상
    • 대한후두음성언어의학회지
    • /
    • 제24권1호
    • /
    • pp.13-17
    • /
    • 2013
  • Laser laryngeal microsurgery is currently the primary method of treatment of various laryngeal diseases. The development of laryngeal microsurgery came from the introduction of a small spot $CO_2$ laser micromanipulator and more precise microlaryngeal instruments. $CO_2$ laser laryngeal microsurgery has enabled very precise surgery because it has small focus size and hemostatic effect. There are some limitations to the use of the $CO_2$ Laser such as adjacent tissue damage and vocal fold scarring. These problems can be minimized through understanding the mechanisms by which lasers function and correctly manipulating the parameters under a surgeon's control. We should also recognize the safety of $CO_2$ laser for the surgeon to precisely perform the procedure.

  • PDF

레이저를 이용한 임프란트 이차수술시 온도변화에 관한 실험적 연구 (TEMPERATURE CHANGES OF IMPLANT SURFACE IN SECOND STAGE SURGERY WITH DETAL LASER : IN VITRO STUDY)

  • 안현정;김현철;최병갑;송언희;김래경
    • 대한치과보철학회지
    • /
    • 제37권2호
    • /
    • pp.256-268
    • /
    • 1999
  • Submerged implants require secondary surgical uncovering of implants after healing period of 3-6 months. In surgical methods, there are surgical scalpel, tissue punch, electro-surgical, and laser-used uncovering, and so forth The objectives of this study are investigation and assessment of 1) thermal change in clinical application for uncovering of HA-coated implant and pure titanium implant irradiated by pulsed Nd-YAG, $CO_2$, and Er-YAG laser. 2) surface change of cover screws aaer irradiation using laser energy. The temperature of apex & side wall of implants were recorded at 10sec, 20sec, 30sec after 30sec irradiation to implant healing screw; 1) pulsed Nd-YAG laser; 2W, 20pps, contact mode 2) $CO_2$ laser; water-infused & non-water infused state, 2.5-3.5W, contibuous mode, noncontact mode 3) $CO_2$ laser ; non-water infused state, 3W, superpulse, noncontact. mode 4) Er-YAG laser; (1) non-water infused state, 10pps, 60mj, contact mode (2) water-infused state, 10pps, 60mj, 80mj, 101mj, contact mode. According to the results of this study, pulsed Nd-YAG laser is not indicated because of increased thermal change and pitting of metal surface of implant cover screw. By contrast, $CO_2$ laser & Er-YAG laser are presumed to indicate because of narrow range of thermal change & near abscence of thermal damage of metal surface. Dental laser is thought to be much helpful to surgical procedure when it is used as optimal power and time condition considering characteristics and indications of each laser. Further research is needed to verify that these techniques are safe and beneficial to implant success.

  • PDF

돼지에서 $CO_2$ laser와 외과용 수술도를 이용한 위 절개 시 창상 치유 평가 (Comparative Study of Wound Healing in Porcine Stomach with $CO_2$ Laser and Scalpel Incisions)

  • 변홍섭;이재연;김명철
    • 한국임상수의학회지
    • /
    • 제30권4호
    • /
    • pp.247-252
    • /
    • 2013
  • We compared wound healing with $CO_2$ laser incision and scalpel incision by measuring the extent of bleeding, the ease of incision, time, degrees of adhesion and histological observation in pig's stomach. Eight healthy pigs were used. Two symmetrical incisions were made in ventral aspect of the stomach between the greater curvature and lesser curvature were made with scalpel and 2 mm spot diameter $CO_2$ laser (8W, continuous wave) in eight pigs. And then each wound was closed with absorbable suture in a two-layer inverting seromuscular pattern. At 7 and 14 days after initial wounding, each wound was taken for histological observation. On surgery, the extent of bleeding, the ease of incision and incision time showed significant differences between the two groups. The $CO_2$ laser provided better hemostasis (p < 0.01) and smaller postoperative adhesion compared with the scalpel. However, the scalpel produced faster speed of incision and was easier to handle than the $CO_2$ laser group (p < 0.01). There was no considerable difference between the two groups in histological observation.

보호가스 종류에 따른 고출력 레이저 용접특성 (The Effect of Shielding Gas Composition on High Power Laser Welding Characteristics)

  • 안영남;김철희
    • Journal of Welding and Joining
    • /
    • 제33권4호
    • /
    • pp.17-23
    • /
    • 2015
  • Laser-gas metal arc hybrid welding has been considered as an alternative process of gas metal arc welding for offshore pipe laying. Fiber delivered high power lasers which enable deep penetration welding were recently developed but high power welding characteristics were not fully understood yet. In this study, the influence of shielding gas composition on welding phenomena in high power laser welding was investigated. Bead shapes, melt ejection and dropping were observed after autogenous laser welding with 100% Ar, Ar-20% $CO_2$, Ar-50% $CO_2$, and 100% $CO_2$ shielding gas. Process parameter window was widest with Ar-50% $CO_2$ shielding gas and the penetration was deepest with 100% $CO_2$ shielding gas. The melt dropping was not observed when Ar-50% $CO_2$ or 100% $CO_2$ shielding gas was supplied.

후두미세수술에서 탄산가스 레이저를 이용한 레이저 수술의 안전성 (Laser Safety in Laryngeal Microsurgery Using $CO_2$Laser)

  • 이정구;정필상;정필섭
    • 대한기관식도과학회지
    • /
    • 제4권2호
    • /
    • pp.159-164
    • /
    • 1998
  • The developmental and subsequent addition of laser technology to existing surgical techniques offered new and exciting Possibilities for improving traditional endoscopic operations and expanding the scope of the specialty of otolaryngology-head and neck surgery. Lasers were found to be Precise, but potentially dangerous, surgical instruments whose use was associated with certain distinct and unprecedented advantages, but also with many unique and potentially serious, and sometimes catastrophic complications. The Purpose of this study was to evaluate the of elation technique of $CO_2$laser, kinds of anesthesia, equipments of operating room, and education of medical staff. Four hundreds 4 cases of $CO_2$laser laryngeal microsurgery were reviewed for the safety of $CO_2$laser in laryngeal microsurgery. Vocal polyp (46,3%) was the most common pathology in our cases. The others were vocal nodule, Reinke`s edema, epiglottic cyst, laryngeal granuloma, laryngeal papilloma, intracordal cysts, laryngeal tuberculosis, laryngeal web, laryngotracheal stenosis, and laryngeal cancer. Following complete equipment controls, treatment area controls, maintenance, service and procedural controls, personel protective equipment, and warning signs, no complications were found in our cases. In conclusion, laryngeal microsurgery with $CO_2$laser could be done safely without complication if complete preoperative preparation and education of medical staff preceded.

  • PDF

CO2 레이저 침구 치료의 역사 (The History of CO2 Laser Acupuncture and Moxibustion)

  • 장인수;양창섭;선승호;정민정;한창호;황의형;서형식
    • Korean Journal of Acupuncture
    • /
    • 제36권1호
    • /
    • pp.36-43
    • /
    • 2019
  • Objectives : Carbon dioxide ($CO_2$) laser, a high power laser has been used for pain management, dermatology, and surgery and laser acupuncture and moxibustion as well, since it had been oscillated in 1964 at Bell Telephone Laboratories in the US. The purpose of this study is to investigate the history of $CO_2$ laser acupuncture through reviewing studies published in early stage of laser medicine. Methods : To investigate the early history of $CO_2$ laser acupuncture, studies were searched in the electronic databases, including PubMed, ScienceDirect, CNKI, Wanfang, J-STAGE, CiNii, KTNP, and OASIS, since 1964. Articles in English, Chinese, Japanese and Korean were included, and there were no limitations in literature types such as reviews, essays, clinical trials, animal experiments and veterinary research. Results : We found that the first $CO_2$ laser application to acupoints was done by a research team in Shanghai in 1976. They used $CO_2$ laser for acupuncture treatment and it was also the first laser acupuncture treatment in China. Since the first case report of $CO_2$ laser for leukopenia, it has been applied to various diseases in China, Korea, Japan and other western countries. It has been widely applied in the fields of dentistry and veterinary medicine, as well as clinical applications. Conclusions : Not only $CO_2$ laser can be used as laser acupuncture by stimulating the acupoints and meridians, but also can produce moxibustion effect by using heat stimulus. Therefore, it is expected that it will be used in various clinical fields in the future.

방전 플라즈마 빛의 검출량과 CO2레이저 출력의 상관관계 (The relativity of the emitted light of discharge plasma and C02 laser output)

  • 김태균;이임근;최진영;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1954-1956
    • /
    • 2004
  • Nowadays, $CO_2$ lasers are used widely in many applications such as materials fabrication, communications, remote sensing and military purpose etc. Especially, $CO_2$ lasers are in the spotlight at surface handling and heat processing. It is important to control the laser output power and beam Quality in those fields. And those are studied the important parameters deciding the fluctuation of laser beam are smoothing capacitor, frequency and the characteristics of laser resonator. But the study of plasma parameters of $CO_2$ lasers are little. So we detect the $CO_2$ laser from emitted $CO_2$ laser discharge plasma using a non-contact photo tansistor sensor and Low pass filter. In this study, The relativity of the emitted light of discharge plasma and CO2 laser output.

  • PDF