• Title/Summary/Keyword: $CO_2$ Concentration

Search Result 5,314, Processing Time 0.034 seconds

A Study on the Analysis of $CO_2$ Concentration Variation According to the Indoor Space Condition Changes (다양한 실내 환경에서의 $CO_2$ 농도 변화 분석 연구)

  • Ahn, Gwang-Hoon;Kwon, Jong-Won;Kim, Gyu-Sik;Kim, Hie-Sik
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.347-349
    • /
    • 2009
  • Air quality of indoor space environment is affected by various pollutants like as particles and chemical stuffs. The indoor air pollution affects directly the human respiration organs to cause consequently unpleasant mental status. The $CO_2$ concentration level is one of the harmful components of air pollutants. Major factor to increase the $CO_2$ concentration level is the people's breath amount in indoor. The car exhaust gas diffused from the around road also has strong affect on $CO_2$ concentration. There are some other reasons to affect the $CO_2$ concentration change, such as, real-time change of the population movement, closeness to the indoor air flow inlet window and changes in road car traffic amount. A remote monitoring system to measure environmental indoor air pollution concerning on the $CO_2$ concentration was studied and installed realized set-up model. Zigbee network configuration was applied for this system and the $CO_2$ concentration data were collected through USN network. A software program was developed to assure systematic analysis and to display real-time data on web pages. For the experimental test various condition was set up, like as, window opening, stopping air condition operation and adjusting fan heater work, etc. The analysis result showed the relation of various environmental conditions to $CO_2$ concentration changes. The causes to increase $CO_2$ concentration were experimentally defined as windows closing, the stopping air condition system, fan heater operation. To keep the $CO_2$ concentration under the legally required ppm level in public access indoor space, the developed remote measurement system will be usefully applied.

  • PDF

A Comparative Analysis on Concentration of Pollutants in Housing Indoor-Air between Winter and Summer (주택 실내 공기중 오염물질 농도의 동절기와 하절기 비교 분석)

  • Nam, Ki-Cheul;Lee, Young-Han;Choi, Bong-Seok
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.125-131
    • /
    • 2017
  • Purpose: The study is to measure concentrations of indoor air pollutants in housing and to analyze the characteristics of pollutants in housing indoor-air between summer and winter comparatively. The research result could be used as data for public health through indoor air quality management of existing housing and more as a reference for new housing. Method: It was investigated 24 middle class housings of metropolitan area in winter which have been built for the past 30 years. Concentration of HCHO, TVOC was investigated in living room at morning and night and concentration of $CO_2$ was investigated in living room and master bedroom at morning and night. SKT100-X5 was used for concentration of HCHO, TVOC and ZGm053UK for concentration of $CO_2$. The characteristics of HCHO, TVOC, $CO_2$ concentration in winter were analyzed and then the concentrations in winter were analyzed the concentrations in summer being preceding research comparatively. Result: Average concentration of TVOC in winter was 2.7 times more than that of TVOC in summer, average concentration of HCHO in winter was about 2.0 times more than that of HCHO in summer. Average concentration of $CO_2$ in the morning at living room in winter was 1.3 times more than that of $CO_2$ in summer. Average concentration of $CO_2$ in the morning at master bedroom in winter was 1.1 times more than that of $CO_2$ in summer. Average concentration of TVOC was 1.31 times more than that of HCHO and standard deviation of that was 1.73 times higher. Average concentration of $CO_2$ was almost nearly close or over to 1,000ppm being criteria of the Ministry of Environment.

Development of a Fast-Response $CO_2$ Analyzer using NDIR Technique and Its Application to SI Engine (비분산 적외선 흡수법을 이용한 고속응답 $CO_2$ 분석기의 제작 및 엔진 적용에 관한 연구)

  • Lee, Jae-Young;Min, Kyoung-Doug
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.6
    • /
    • pp.102-107
    • /
    • 2007
  • A fast response $CO_2$ ($fCO_2$) analyzer for real-time measurement of carbon dioxide concentration during transient states of internal combustion engines has been developed. This analyzer uses non-dispersive infrared absorption (NDIR) technique for measuring $CO_2$ concentration and Kalman filter for removing noise components from output signals. The analyzer has good linearity, repeatability and drift with a response time of 11 ms; it is sufficiently fast to detect $CO_2$ concentration during transient states of internal combustion engines. The $fCO_2$ analyzer was used to measure transient $CO_2$ concentration of exhaust gas of the SI engine with a standard gas analyzer, and the signal of the $fCO_2$ analyzer was compared to that of the standard gas analyzer. The two concentrations were well matched during the steady state, and the $fCO_2$ analyzer could measure the variations of $CO_2$ concentration during the transient state.

CA Storage for Ginger Depending on CO2 Concentrations (탄산가스 농도에 따른 생강의 CA 저장효과)

  • 정문철;이세은
    • Food Science and Preservation
    • /
    • v.5 no.2
    • /
    • pp.133-137
    • /
    • 1998
  • In order to establish effectiveness of CA storage and adequate CO2 concentration, it was investigated the quality chanties of Singer during CA storage for 150 days at different CO2 concentrations ranging from 3% to 12% and 3% fixed oxygen concentration. Weight loss tend to decrease with increase of CO2 concentrations. Sprouting ratio and the loss of gingerol was shown to be less as CO2 concentration increase but to be more than control stored at 12$^{\circ}C$, 95% RH within the concentration less than 6% CO2.

  • PDF

Interactive Effects of Increased Temperature and pCO2 Concentration on the Growth of a Brown Algae Ecklonia cava in the Sporophyte and Gametophyte Stages (갈조류 감태(Ecklonia cava)의 포자체와 배우체 생장에 영향을 주는 수온과 pCO2 농도의 상호작용)

  • Oh, Ji Chul;Yu, Ok Hwan;Choi, Han Gil
    • Ocean and Polar Research
    • /
    • v.37 no.3
    • /
    • pp.201-209
    • /
    • 2015
  • To examine the effects of increased $CO_2$ concentration and seawater temperature on the photosynthesis and growth of forest forming Ecklonia cava (Laminariales, Phaeophyta), sporophytic discs and gametophytes were cultured under three $pCO_2$ concentrations (380, 750, 1000 ppm), four temperatures (5, 10, 15, $20^{\circ}C$ for sporophytes; 10, 15, 20, $25^{\circ}C$ for gametophytes), and two irradiance levels (40, $80{\mu}mol$ photons $m^{-2}s^{-1}$) for 5 days. Photosynthetic parameter values ($ETR_{max}$, $E_k$, and ${\alpha}$) were generally higher as sporophytic discs were grown under low temperature and increased $CO_2$ concentration at 750 ppm. However, photosynthesis of Ecklonia sporophytes was severely inhibited under a combination of high temperature ($20^{\circ}C$) and 1000 ppm $CO_2$ concentration at the two photon irradiance levels. The growth of gametophytes was maximal at the combination of 380 ppm (present seawater $CO_2$ concentration) and $25^{\circ}C$. Minimal growth of gametophytes occurred at enriched $pCO_2$ concentration levels (750, 1000 ppm) and high temperature of $25^{\circ}C$. The present results imply that climate change which is increasing seawater temperature and $pCO_2$ concentration might diminish Ecklonia cava kelp beds because of a reduction in recruitments caused by the growth inhibition of gametophytes at high $pCO_2$ concentration. In addition, the effects of increased temperature and $pCO_2$ concentration were different between generations - revealing an enhancement in the photosynthesis of sporophytes and a reduction in the growth of gametophytes.

A Study on Air Pollution and Thermal Factors in Underground Shopping Center of Pusan Area (부산시내 지하생활권의 공기오염도와 온열인자에 관한 조사연구)

  • Choi, Sung-Yong;Moon, Deog-Hwan;Lee, Jong-Tae;Song, In-Hyuk;Lee, Cha-Eun;Lee, Sung-Min
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.3 s.47
    • /
    • pp.505-516
    • /
    • 1994
  • For the purpose of preparing the fundamental data on air pollution in underground shopping center and also contributing to the health improvement of residents, the authors measured the level of $SO_2,\;NO_2,\;TSP,\;CO,\;CO_2$ and also some related factors as air temperature, air movement, relative humidity and mean radiation temperature at inside and outside of underground shopping center in Pusan from January to February and from July to August 1994. The results were as follows : 1. The mean concentration of CO within the underground shopping center was $3.1{\pm}1.3ppm$ in winter and $2.1{\pm}0.9ppm$ in summer. There was a negative correlation (p<0.01) between inner CO concentration and temperature in summer and no correlation between inner CO concentration and outer CO concentration in underground shopping center 2. The mean concentration of COE within the underground shopping center was $876{\pm}353ppm$ in winter and $757{\pm}125ppm$ in summer. There was a negative correlation (p<0.01) between inner $CO_2$ concentration and air movement in summer and positive correlation (p<0.05) between inner $CO_2$ concentration and outer $CO_2$ concentration in underground shopping center. 3. The mean concentration of $SO_2$ within a underground shopping center was $0.036{\pm}0.019ppm$ in winter and $0.040{\pm}0.013ppm$ in summer. There was a positive correlation(p<0.01) between inner $SO_2$ concentration and temperature in summer and positive correlation between inner $SO_2$ concentration and outer $SO_2$ concentration in summer and winter in underground shopping center. 4. The mean concentration of $NO_2$ within a underground shopping center was $0.052{\pm}0.038ppm$ in winter and $0.042{\pm}0.016ppm$ in summer. There was a no correlation between inner $SO_2$ concentration and thermal factors in summer and winter and low correlation between inner $SO_2$ concentration and outer $SO_2$ concentration in underground shopping center 5. The mean concentration of TSP within a underground shopping center was $430{\pm}214{\mu}g/m^3$ in winter, $366{\pm}73{\mu}g/m^3$ in summer, and very in excess of the atmospheric environmental quality standards of Korea ($150{\mu}g/m3{\downarrow}$). There was low correlation between inner TSP concentration and temperature in summer and high correlation between inner TSP concentration and outer TSP concentration in underground shopping center.

  • PDF

Development of high-resolution atmosphere ocean coupled model and global warming projection with Earth Simulator -A whole research plan and result in FY2002-

  • Maruyama, Koki
    • Proceedings of the Korean Society of Coastal and Ocean Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.18-27
    • /
    • 2003
  • The goal of the UN Framework Convention on Climate Change (UNFCCC) is to stabilize atmospheric CO2 concentration for preventing global warming in future. However, there are many unknown factors regarding stabilization of CO2 concentration. What level of concentration should be appropriate to prevent global warming? When should we stop the increase of CO2 concentration\ulcorner What kind of countermeasures of reducing CO2 emission will be available for CO2 stabilization?(omitted)

  • PDF

A Study of the Characteristics of Flow and the Distribution of $CO_2$ Agent Concentration According to the Number of $CO_2$ Agent Nozzle ($CO_2$소화제 노즐수에 따른 유동특성 및 소화제농도분포에 대한 연구)

  • Park Chan-Su
    • Fire Science and Engineering
    • /
    • v.19 no.2 s.58
    • /
    • pp.37-44
    • /
    • 2005
  • We have conducted a numerical simulation under three-dimensional unsteady conditions in order to analyze the characteristics of flow and the distribution of $CO_2$ agent concentration according to the number of $CO_2$ agent nozzle. The engine room of a ship was selected as a protection space, and flow fields and $CO_2$ concentration fields were measured. In case of increasing the number of $CO_2$ nozzle from 2 nozzles to 4 nozzles, the distribution of CO2 concentration showed low, and in case of increasing the number of $CO_2$ nozzle to above 6 nozzles, the recirculating flow affected to all region was generated. In case of increasing the number of $CO_2$ agent nozzle to above 4 nozzles, the iso-concentration line below 0.36 expanded or contracted slightly. Therefor, the proper number and the arrangement of $CO_2$ agent nozzle are considered when $CO_2$ fire fighting system is designed.

A Suggestion of indoor CO2 concentration prediction equation by operating KTX flap in Tunnel Sections (터널구간 운행시 KTX 플랩 작동에 따른 CO2 농도 예측식 제안)

  • So, Jin-Sub;Yoo, Seong-Yeon;Kim, Ick-Hee
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.2052-2057
    • /
    • 2010
  • In December 2006, the Ministry of Environment in Korea established the "Indoor Air Quality Management Guidelines in Public Transportation." As the items of the guideline, $CO_2$(Carbon dioxide) and PM10(Particulate matter). Therefore, the air quality inside the train is supposed to be ruled by this guideline. This study calculated the increase or decrease rate of the $CO_2$ concentration by using the data measured in accordance with flap operation. In case of flap close or open, the calculated $CO_2$ concentration variation was 6.32ppm/min. The $CO_2$ concentration prediction equation was derived from the general equation and the actual measured value are compared with the predicted $CO_2$ concentration suggested during the KyungBu high speed railway construction. The predicted value show good agreement with the measured data.

  • PDF

Interrelationship between Kimchi Ripening and CO2 Concentration of the Headspace in Flexible Packages Included with CO2 Absorber (CO2 흡수제 함유 김치포장에서 CO2 농도와 제품 숙성도의 상호관련성)

  • Jung, Soo Yeon;Lee, Dong Sun;An, Duck Soon
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.26 no.2
    • /
    • pp.71-76
    • /
    • 2020
  • CO2 concentration in kimchi package has emerged recently as a potential index of product ripening to be monitored or sensed in intelligent packaging. Considering that addition of CO2 absorber into the flexible kimchi package changes behavior of its CO2 concentration, ripening of kimchi in total acidity, package CO2 concentration in partial pressure (PCO2) and package volume at 10℃ were estimated by mathematical model for two size packages included with different CO2 absorbers. In small size package containing 0.5 kg of kimchi, relatively less gas permeable low density polyethylene (LDPE) sachet of the absorber was found to give rise of PCO2 linearly correlated with acidity at acceptable conditions of absorber amount and size. The levels of PCO2 at optimum ripening were different with absorber amount. However, highly gas permeable microporous spunbonded film (Tyvek) sachet did not show the linear relationship except a condition of 1.5 g of CO2 absorbent. In large size package containing 2.0 kg, absorber sachets of LDPE and Tyvek could give the linear relationship between product acidity and package PCO2 but at different levels (PCO2 of package with LDPE sachet: 0.46~0.79 bar, PCO2 of package with Tyvek sachet: 0.00~0.75 bar). The PCO2 at optimal ripening was found to be less variable with LDPE sachets than with Tyvek ones. Use of package CO2 concentration as an indicator of kimchi ripening was shown to be possible on the limited conditions where the linear relationship between them is established or confirmed.