• Title/Summary/Keyword: $COD_T$

Search Result 854, Processing Time 0.025 seconds

Ammonia Effects on Anaerobic Digestion of Swine Wastewaters (양돈폐수의 혐기성 소화에 대한 암모니아의 영향)

  • Kim, Jong-Soo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.10 no.1
    • /
    • pp.102-108
    • /
    • 2002
  • The effects of ammonia on mesophilic anaerobic digestion were investigated by operating lab-scale two-stage ASBF reactors using swine wastewaters as influent without and with ammonia removal at HRT of 1-2 days and OLR of $2.2{\sim}9.6kg-COD/m^3{\cdot}d$ for 250 days. The COD removal efficiency and biogas generation of two-stage ASBF reactors was decreased by increasing influent ammonia concentrations to 1,580 mg(T-N)/L with increasing OLR to $6.3kg-COD/m^3{\cdot}d$, while those were increased by maintaining influent ammonia concentrations below 340 mg(T-N)/L by MAP precipitation with increasing OLR to $9.6kg-COD/m^3{\cdot}d$. Initial inhibirion of ammonia on anaerobic processes was observed at a concentration of 760 mg(T-N)/L and the COD removal efficiency and biogas generation dropped to 1/2 at ammonia concentration ranges of 1,540~1,870 mg(T-N)/L. It is essential to remove ammonia in swine wastewaters to an initial inhibition level before anaerobic processes for the effective removal of COD.

  • PDF

A Study on the filtering bed of porous sintering-product and hydrophytes for sewage treatment (오·폐수처리를 위한 수생식물 다공성 소결체여상의 기초연구)

  • Kim, Ju-Hyung;Yun, Chan;Oh, Joon-Seong
    • Clean Technology
    • /
    • v.7 no.2
    • /
    • pp.89-97
    • /
    • 2001
  • The purpose of this study was to find the optimum condition of the high removal efficiency of water pollutant as sewage treatment technology using a filtering bed charged with porous sintering-pellet which was planted with hydrophytes. Experiment was carried out by changing concentration of water pollutants(COD, T-N, T-P), kind of hydrophyte, kinds of filtering material and size, and HRT. The result of removal efficiency was obtained as following: COD removal 73.8~87.1% for input concentration range of 50~450mg/L, T-N removal 61.3~77.3% for input concentration range of 7~124mg/L, T-P removal 89.5~99.1% for input concentration ranger of 3~27mg/L. In a comparative experiment of three kinds of hydrophyte(Iris pseudoacorus, Phragmites communis $T_{RIN}$., Oenanthe javanica Dc.), the best removal efficiency of COD and T-N was gained with Iris pse-udoacorus, and Phragmites communis $T_{RIN}$ showed better result than two hydrophytes for the removal efficiency of T-P. In a comparative experiment of four kinds of filtering-materials, the removal efficiencies were in the order of porous sintering-pellet, gravel, nonused-tire and nonused-concrete. It was found that for the porous sintering-pellet, the smaller its diameter, the better its result. In the filtering bed in which was charged with porous sintering-pellets of 5mm diameter and planted with Iris pseudoacorus, the removal efficiency of COD, T-N and T-P were over 80%, 70% and 90% under the concentration of COD 250mg/L, T-N 70mg/L and T-P 15mg/L for 24hrs treatment. Thus, we concluded that a filtering bed charged with porous sintering-pellet and planted with hydrophytes will be suitable for treatment of sewage water as a pro-natural treatment technology.

  • PDF

Monitoring and research of NPS pollution priority Management - Jaun district Watershed (자운지구 비점오염원 관리를 위한 모니터링 연구)

  • Park, Byeong Ky;Shin, Jae Young;Lee, Su In;Ju, So Hee;Cho, Joong Dae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.524-524
    • /
    • 2016
  • 본 연구에서는 홍천 자운지구 고랭지 농업지역을 대상으로 장기간의 유역조사와 하천 모니터링을 통해 관측된 축척 데이터를 이용하여 비점오염저감 효과를 정량화하고 추후 모니터링 자료로서 탁수와 비점오염원 저감시설의 저감효과와 비점오염원의 효율적인 관리를 위한 기초자료를 제공하고자 하였다. 모니터링 결과 소양호 유역의 오염부하(1차 강우사상) 중 홍천군 자운지구의 유역단위 비점오염 저감효과의 분석에는 강우량과 단위면적당 오염부하를 이용하였으며, 자운천은 SS 5,396,761 kg, COD 82,261 kg, BOD 57,329 kg, T-N 68,711 kg, T-P 3,091 kg이었으며, 오염부하(2차 강우사상)는 SS 320,293 kg, COD 34,588 kg, BOD 22,350 kg, T-N 48,954 kg, T-P 640 kg으로 나타났다. 또한 소양호 유역의 EMC(1차 강우사상) 중 자운천은 SS 829.9 mg/L, COD 12.7 mg/L, BOD 8.8 mg/L, T-N 10.567 mg/L, T-P 0.475 mg/L 이었으며, EMC(2차 강우사상)는 SS 68.6 mg/L, COD 7.4 mg/L, BOD 4.8 mg/L, T-N 10.487 mg/L, T-P 0.137 mg/L로 나타났다. 소양호 유역의 단위면적당 오염부하(1차 강우사상) 중 자운천은 SS 402.0 kg/ha/event, COD 6.1 kg/ha/event, BOD 4.3 kg/ha/event, T-N 5.118 kg/ha/event, T-P 0.230 kg/ha/event 이었으며, 오염부하(2차 강우사상)는 SS 23.9 kg/ha/event, COD 2.6 kg/ha/event, BOD 1.7 kg/ha/event, T-N 3.646 kg/ha/event, T-P 0.048 kg/ha/event로 나타났다. 오염부하에서는 1차 강우에 비해 2차 강우에서는 SS 5,076,468 mg/L, COD 47,673 mg/L, BOD 34,979 mg/L, T-N 19,757 mg/L, T-P 2451 mg/L로 1차 강우사상에 비해 오염부하가 낮은 것으로 나타났다. 또한 EMC에서는 1차 강우에 비해 2차 강우에서는 SS 761.3 mg/L, COD 5.3 mg/L, BOD 4.0 mg/L, T-N 0.080 mg/L, T-P 0.338 mg/L로 1차 강우사상에 비해 EMC가 저감되었다. 단위면적당 오염부하는 1차 강우에 비해 2차 강우에서는 SS 378.1 mg/L, COD 3.5 mg/L, BOD 2.6 mg/L, T-N 1.472 mg/L, T-P 0.182 mg/L로 1차 강우사상에 비해 EMC가 저감되었다. 강우량과 강우강도 그리고 영농활동의 시기에 따른 EMC와 단위면적당 오염부하는 큰 차이를 보였으며, 예년에 비해 적은 강수량으로 인해 탁수와 비점오염부하의 배출이 상대적으로 적었던 것으로 판단된다. 소양호 유역과 같은 넓은 유역에서 시행되는 비점오염원의 저감연구는 오랜 시간 동안 자료를 축적해야 유의미한 평가가 이루어질 수 있으므로 장기적이고 지속적인 모니터링을 통한 유량 데이터 자료구축과 수질분석뿐만 아니라, 발생되는 비점오염 물질의 관리를 위한 체계적인 연구가 지속되어야하며, 아울러 농민의 인식도 변화 등을 포함하는 많은 인자들을 정밀히 조사하고 다각도로 분석하여 저감효과에 대한 지속적인 연구가 필요하다.

  • PDF

Performance Evaluation of Anaerobic Bioreactors and Effects of Ammonia on Anaerobic Digestion in Treating Swine Wastewaters

  • Lee, Gook-Hee;Seo, Jun-Won;Kim, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.3
    • /
    • pp.195-201
    • /
    • 2006
  • The operational characteristics of anaerobic bioreactors in treating swine wastewater were evaluated upto hydraulic retention time (HRT) of 1 day and organic loading rate (OLR) of $5.1kg-COD/m^3{\cdot}d$ for 200 days. The bioreactors were effective in treating swine wastewaters with COD removal efficiency of $78.9{\sim}81.5%$ and biogas generation of $0.39{\sim}0.59m^3/kg-COD_r$ at OLR of $1.1{\sim}2.2kg-COD/m^3{\cdot}d$. The two-stage ASBF anaerobic bioreactors was effective in treating different characteristics of swine wastewaters since they showed high and stable COD removal efficiency at high OLR due to effective retention of biomass by media and staging. The effects of ammonia on anaerobic digestion were investigated by operating two-stage ASBF reactors using swine wastewaters as influent without and with ammonia removal at HRT of $1{\sim}2$ days and OLR of $2.2{\sim}9.6kg-COD/m^3{\cdot}d$ for 250 days. The COD removal efficiency and biogas generation of two-stage ASBF reactors was decreased by increasing influent ammonia concentrations to 1,580 mg (T-N)/L with increasing OLR to $6.3kg-COD/m^3{\cdot}d$, while those were increased by maintaining influent ammonia concentrations below 340 mg (T-N)/L by MAP precipitation with increasing OLR to $9.6kg-COD/m^3{\cdot}d$. Initial inhibition of ammonia on anaerobic processes was observed at a concentration of 760 mg (T-N)/L and the COD removal efficiency and biogas generation dropped to 1/2 at ammonia concentration ranges of $1,540{\sim}1,870mg$ (T-N)/L. It is essential to remove ammonia in swine wastewaters to an initial inhibition level before anaerobic processes for the effective removal of COD.

A study on the desulfurization wastewater treatment using Ferrate(VI) (Ferrate(VI)를 이용한 발전소 탈황폐수 처리에 관한 연구)

  • Jo, Eun-young;Park, Chan-gyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.4
    • /
    • pp.297-301
    • /
    • 2017
  • Wastewater treatment using ferrate (VI) solution is becoming a promising technology for several years, because it is high efficient and harmless technology. In this study, the ferrate (VI) solution was tested to treatment of desulfurization wastewater. The effluent from desulfurization wastewater treatment process of power plant was used as raw water, and the COD and T-N removal efficiency of ferrate(VI) solution were investigated. In the test, as the injection rate increased from 0.1 to 1.0%, the removal efficiency of COD also slightly increased, about 80% of COD were removed in 1.0% of injection rate. In the case of T-N, about 50% of T-N was removed in the condition of 1.0% of injection rate. The removal efficiency of COD and T-N also affected by reaction time, maximum removal efficiency was shown in 30 min of treatment. From these results, the wastewater treatment with ferrate(VI) solution can be great solutions for treatment of non-biodegradable pollutants in wastewater, especially for the 3rd treatment of wastewater.

Crack growth instability based on COD-R curve (COD-저항곡선을 이용한 불안정 균열 성장에 관한 연구)

  • 한창석;엄윤용;송지호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.1
    • /
    • pp.53-63
    • /
    • 1988
  • Using COD-R curves, instability of crack growth in ductile material is studied here. Tearing modulus $T_{\delta}$, based on the COA concept is defined and the instability criterion $T_{{\delta}{\app}}$> $T_{{\delta}{\mat}}$ is compared with experiments. Variations of the COD-R curve and the location of rotation center are experimentally investigated as the initial crack ratio varies. Three-point bend specimens of alloy steel SCM4 are used here and two clip-on gauges are installed in order to obtain the COD-R curve. The results show that the tearing modulus $T_{\delta}$ is a good measure to characterize the instability of crack growth. Also it is found that the location of rotation center is almost constant regardless of the initial crack ratio and the amount of the crack growth.

The Removal of Organics, Nitrogen and Phosphorus in Loop Reactor Using Fluidized Media (유동상 담체를 이용한 Loop Reactor에서 유기물 및 질소, 인 제거)

  • Seon, Yong-Ho
    • KSBB Journal
    • /
    • v.24 no.4
    • /
    • pp.353-360
    • /
    • 2009
  • This study was accomplished using Anaerobic/Anoxic/Oxic upflow packed-bed column reactors with fixed media and Loop Reactor with fluidized media instead of Oxic reactor. The objectives of this study was to investigate the characteristics of organics, nitrogen and phosphorus removal from sewage with the HRT. The average removal efficiencies of $BOD_5$ and SS increase as increasing the hydraulic retention time (HRT) until 16 h of the HRT, and they were constant over 16 h of the HRT. The removal efficiency of $BOD_5$ in case of packed-bed reactor and Loop Reactor was about 86.6% and 90.9% respectively at 16 h of the HRT. The removal efficiency of SS in packed-bed reactor and Loop Reactor was about 78.0% and 88.2% respectively at 16 h of the HRT. The average removal efficiencies of $COD_{Cr}$ and $COD_{Mn}$ showed similar trends as those of $BOD_5$ and SS. At the HRT of 16 h, the removal efficiency of $COD_{Cr}$ in case of packed-bed reactor and Loop Reactor was 63.5%, 75.2% and that of $COD_{Mn}$ was 60.7%, 73.6% respectively. The average removal efficiencies of T-N and T-P increase as increasing the HRT. The removal efficiencies of T-N and T-P in Loop Reactor were 33.6% and 54.5% respectively at 16 h of the HRT and T-N and T-P were better removed in Loop Reactor. From this result, it was found that the performance of Loop Reactor was much higher than the performance of packed-bed reactor and the optimum HRT was 16 h.

Treatment Efficiency of Existing Forms of Pollutants in Sewage Treatment Plant by Natural Purification Method (자연정화공법에 의한 하수처리장에서 오염물질의 존재형태별 처리효율)

  • Seo, Dong-Cheol;Lee, Byeong-Ju;Hwang, Seung-Ha;Lee, Hong-Jae;Cho, Ju-Sik;Lee, Sang-Won;Kim, Hong-Chul;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.2
    • /
    • pp.129-137
    • /
    • 2006
  • A study was conducted to investigate the behavior of pollutant forms at each area in the sewage treatment plant by natural purification method. The sewage treatment plant by natural purification method that consisted of aerobic and anaerobic area was constructed. The efficiency of sewage treatment depending on the operation time, the loading amount of pollutant season variation were investigated. The removal amount of BOD, COD, TOC and SS in the aerobic area was significantly increased as the treatment proceeded. Decreased BOD, COD, TOC, SS, T-N and T-P depending on the loading amount of pollutants in the aerobic and ananerobic area were mostly insoluble BOD (IBOD), insoluble COD (ICOD), soluble TOC (STOC), volatile SS (VSS), dissolved T-N (DTN) and dissolved T-N (DTP) types, respectively. The removal efficiency of BOD, COD, TOC, SS, T-N and T-P in hot season (summer and autumn) were more than that in cold season (spring and winter). The removal efficiencies of BOD, COD, TOC, SS, T-N and T-P of the effluent were about 92, 89, 73, 95, 46 and 84% in all seasons, respectively.

Evaluation of biological treatment of cutting-oil wastes using sequencing batch reactor (SBR) process (연속 회분식 반응조 (SBR) 공정을 이용한 폐절삭유의 생물학적 처리능 평가)

  • Baek, Byung-Do;Kim, Chang-Seop;Kim, Jun-Young;Chang, In-Soung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.7
    • /
    • pp.1654-1660
    • /
    • 2009
  • Two different cutting-oils from H and B companies which are sold as an eco-friendly cutting-oils were selected and the biodegradability of these commercially available cutting-oils was evaluated by the sequencing batch reactor (SBR) processes. The cutting-oil wastes ($H_1$) pre-treated by coagulation/flocculation was used as an influent to SBR. When the F/M ratio was operated 0.04 to 0.08kgCOD/kgMLSS d, removals of $BOD_5$and $COD_{Cr}$were above 97% and 91%, respectively. T-N and T-P removals were above 76% and 81%, respectively. If the diluted cutting-oil wastes ($B_1$) was used as an influent of the SBR, $COD_{Cr}$removals were above 77% at the F/M ratio of 0.01-0.02kgCOD/kgMLSS d. After the cutting-oil wastes was treated by coagulation/ flocculation ($B_2$), $COD_{Cr}$removals was above 85%. If the pre-treated cutting-oil wastes were mixed with a synthetic wastewater ($B_3$) and fed into the SBR in order to mimic the real wastewater treatment plant situation, $BOD_5$and $COD_{Cr}$removals were above 97%, 91%, respectively. T-N and T-P removals were above 79% and 76%. The ratio between $BOD_5$and $COD_{Cr}$, ($COD_{Cr}$-$BOD_5$)/$COD_{Cr}$, indicating the biodegradability of effluent of the SBR, was calculated to 85% and 61%. This means that significant amounts of non-readily-biodegradable organic compounds in the effluent of $H_1$, $B_3$are still present.

Electrochemical Treatment of COD and T-N in Wastewater from Flue Gas Desulfurization Process (전해처리법에 의한 탈황폐수 중의 COD 및 총 질소 제거)

  • Cha, Go-Eun;Noh, Da-Ji;Seo, Jeong-Hyeon;Lim, Jun-Heok;Lee, Tae-Yoon;Lee, Jea-Keun
    • Journal of Environmental Science International
    • /
    • v.22 no.9
    • /
    • pp.1073-1078
    • /
    • 2013
  • This paper presents the results of the electrochemical treatment of chemical oxygen demand(COD) and total nitrogen(T-N) compounds in the wastewater generated from flue gas desulfurization process by using a lab-scale electrolyzer. With the increase in the applied current from 0.6 Ah/L to 1.2 Ah/L, the COD removal efficiency rapidly increases from 74.5% to 96%, and the T-N removal efficiency slightly increases from 37.2% to 44.9%. Therefore, it is expected that an electrochemical treatment technique will be able to decrease the amount of chemicals used for reducing the COD and T-N in wastewater of the desulfurization process compared to the conventional chemical treatment technique.