• Title/Summary/Keyword: $360^{\circ}$

Search Result 634, Processing Time 0.026 seconds

Paleomagnetism and Radiometric Age of Trachytes in Jeju Island, Korea (한국(韓國), 제주도(濟州島)에 산출(産出)하는 조면암류(粗面岩類)의 고지자기(古地磁氣) 및 절대연령(絶對年齡)에 관(關)한 연구(硏究))

  • Won, Jong Kwan;Matsuda, Jun-ichi;Nagao, Keisuke;Kim, Kwang Ho;Lee, Moon Won
    • Economic and Environmental Geology
    • /
    • v.19 no.1
    • /
    • pp.25-33
    • /
    • 1986
  • The geology of the Jeju island is characterized by the occurrence of thick voluminous basaltic lava flows and minor trachytic lavas. The land form can be divided topographically into the lava plateau, the shield-shaped Halla volcanic edifice and the parasitic cones whose number is more than 360, which is closely related to the cyclic volcanism of the island. Especially, the trachytic lavas seem to be the latest differentiation products of the cyclic activities and largely classified into two groups (Backlokdam group and Sanbangsan group) on the basis of the occurrence and the petrography. The paleomagnetism and the radiometric age on the two groups of trachyte suggest a lower and an upper time limits of the volcanic stratigraphy of the island. An average age of the trachyte of the Sanbangsan group is $0.733{\pm}0.056m.y.$, and is correlated to a horizon a little lower than the boundary (0.69m.y.) between the Brunches normal epoch and Matuyama reversed epoch. An average age of $0.025{\pm}0.008m.y.$ determined from the Backlokdam trachyte may be corrected to anyone horizon of the Laschamp, or the Lake Biwa, or the Lake Mono excursion. The two groups of trachytes are distributed with the latitude difference of 9'($0.15^{\circ}$), and with age difference of about 0.71 m.y. Assuming that the two trachyte groups were erupted from the same stationary hot spot, the lithosphere comprising the Jeju island is considered to have moved southward with a rate of about 2.3 cm/year.

  • PDF

Identification of process generating formaldehyde in a furniture manufacturer (특정 가구 제조 공장의 포름알데히드 발생 공정 노출 평가)

  • Yoo, Kye-Mook;Lee, Mi-Young
    • Analytical Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.243-247
    • /
    • 2014
  • Formaldehyde is defined as carcinogen causing leukaemia, lymphoma or nasopharyngeal carcinoma at high level of exposure. Furniture-manufacturing workers can be exposed to formaldehyde, which implies serious impact on health of the workers. The authors carried out ambient monitoring of formaldehyde in the field, and identified the source of formaldehyde generated during the working process by testing the condition in the laboratory settings. After sampling formaldehyde in the air with 2,4-DNPH (2,4-dinitrophenylhydrazine) coated silica gel, we extracted formaldehyde derivative with acetonitrile and analyzed the extract using HPLC with UV detector at 360 nm. Formaldehyde was separated by ACQUITY UPLC BEH $C_{18}$ column at a flow rate of 0.5 mL/min using 45% acetonitrile as mobile phase. The workers were exposed to higher level of formaldehyde than normal air. Formaldehyde up to 0.31 ppm was detected in the process of veneer attachment, which exceeded 0.3 ppm, the ceiling value of ACGIH standard. The laboratory test of measuring formaldehyde generated from the glue and veneer used in the attachment process resulted in more formaldehyde generation as the temperature increased, and more from the veneer. Heating the veneer to $100-150^{\circ}C$ following the real condition of the manufacturing site generated 1.14-2.70 ppm of formaldehyde from the sample, which was 2-5 times higher level than Korean limit of exposure (0.5 ppm). As the workers handling and processing the veneer which was produced by wet process had high possibility to be exposed to formaldehyde, urgent improvement and management of working environment of furniture manufacturer is demanded.

Removal of Urinary Calculi by Laparoscopic-Assisted Cystoscopy in Five Dogs (다섯 마리의 개에서 복강경 보조 방광경을 이용한 요로결석 제거)

  • Lee, Seung-Yong;Park, Se-Jin;Jin, So-Young;Kim, Min-Hyang;Seok, Seong-Hoon;Kim, Young-Ki;Lee, Hee-Chun;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.31 no.5
    • /
    • pp.371-375
    • /
    • 2014
  • This article describes the use of laparoscopic-assisted cystoscopy for removal of urinary calculi in five dogs. All dogs had micturition disorder due to urinary calculi. The surgical technique used was same in all cases. A urethral catheter passed into the urinary bladder through the urethra preoperatively. A 5-mm diameter cannula was placed in the ventral midline, 1 to 2 cm cranial to the umbilicus, and the 5-mm laparoscope was introduced via the cannula. A 10-mm diameter cannula was placed adjacent to the apex of the bladder under the visual guidance of laparoscopy. The bladder was then partially exteriorized through the 10-mm portal site, and a stab incision was performed on the bladder wall. The incisional margin of the bladder was sutured to the skin of the second portal site in $360^{\circ}$ simple continuous suture. A 2.7-mm diameter cystoscope with a sheath was introduced into the bladder lumen. The cystic and urethral calculi were removed under the visual guidance of cystoscopy with continuous fluid flushing. No major postoperative complications were identified. During the follow up period (range 7 to 21 months), no episodes of urinary dysfunction or recurrence of clinical signs were observed.

Effect of V and Sb on the Corrosion Behavior and Precipitate Characteristics of Zr-based Alloys for Nuclear Fuel Cladding (핵연료 피복관용 Zr합금의 부식거동 및 석출물 특성에 미치는 V, Sb 첨가의 영향)

  • Jeon, Chi-Jung;Kim, Seon-Jin;Jeong, Yong-Hwan
    • Korean Journal of Materials Research
    • /
    • v.8 no.12
    • /
    • pp.1099-1109
    • /
    • 1998
  • To investigate the effect of V and Sb on the corrosion behavior of Zr- based alloys, corrosion tests were performed on 6 kinds of Zr alloys in an autoclave at $360^{\circ}C$ for 100 days. The transition of the corrosion rate occurred in the sample containing 0.1wt.%V after 10 days but did not occur in the samples containing 0.2wt.%V and 0.4wt.%V. The corrosion resistance of V containing alloys increased with increasing V contents from 0.1 to 0.4wt.% and the alloys containing 0.4wt.%V showed the best corrosion resistance. In the ternary alloys containing 0.1wt.%Sb and 0.4wt.%Sb, the corrosion rate increased significantly from the short exposure time. It was observed that the optimal Sb content for corrosion resistance was 0.2wt.%. The size and volume fraction of precipitates increased with increasing V and Sb contents. The superior corrosion resistance was observed in the Zr alloy having precipitate size of 0.11-0.13$\mu\textrm{m}$. From the result of corrosion behavior and the obserbation of precipitates, the optimal size of the precipitate appear to control the electron conduction in the cathodic reaction and play an important role in maintaining a stable oxide microstructure.

  • PDF

The Effects of Automatically Controlled Rotating Acupuncture on Thermal Allodynia in a Rat Model of Neuropathic Pain: Mediation by Endogenous Opioid System (신경병증성 통증에 대한 자동염전침의 진통효과 및 opioid 기전)

  • Park, Jung-Hyuk;Kim, Sun-Kwang;Na, Hyo-Suk;Moon, Hak-Jin;Min, Byung-Il;Kim, Ki-Hong;Rhim, Sung-Soo;Lee, Soon-Geul;Lee, Sang-Hoon
    • Journal of Acupuncture Research
    • /
    • v.23 no.5
    • /
    • pp.23-29
    • /
    • 2006
  • Objectives : The present study was conducted to evaluate the effects of automatically controlled rotating acupuncture (ACRA) on thermal allodynia in neuropathic pain rats, and to examine whether the endogenous opioid system mediates the effects of ACRA. Methods : For the neuropathic surgery, the right superior caudal trunk was resected at the level between S1 and S2 spinal nerves innervating the tail. Two weeks after the nerve injury, ACRA stimulation with 4 different stimulation conditions (i.e., angle and frequency of rotation: 90o+1Hz, 90o+1/4Hz, 360o+/1Hz, and 360o+1/4Hz) was delivered to the Zusanli (ST36) acupoint for 15 min. The behavioral signs of thermal allodynia were evaluated by the tail immersion test (i.e., immersing the tail in cold $(4^{\circ}C)$ or warm $(4^{\circ}C)$ water and measuring the latency to an abrupt tail movement) before and after the stimulation. In an additional set of experiments, we examined the effects of naloxone (opioid Results : ACRA stimulations under all of the conditions above significantly relieved thermal antagonist, 2mg/kg, i.p.) on the action of ACRA stimulation. allodynia. There is no difference in the anti-allodynic effects among the 4 stimulation conditions. In addition, the effect of ACRA on thermal allodynia was reversed by naloxone pretreatment. Conclusion : These results indicate that ACRA stimulations have relieving effects on thermal allodynia in neuropathic pain rats, irrespective of stimulation parameters, and that this is mediated by the endogenous opioid system.

  • PDF

Realization of sensitivity symmetry of Hall Sensor using Trench Structure and Ferromagnetic Thin Films (트랜치 구조 및 강자성체 박막을 이용한 홀 센서의 감도 대칭성 구현)

  • Park, Jae-Sung;Choi, Chae-Hyoung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.4
    • /
    • pp.29-34
    • /
    • 2008
  • Generally, for conventional 3-D Hall sensor it is general that the sensitivity for $B_z$ is about 1/10 compared with those for $B_x$ or $B_y$. Therefore, in this work, we proposed 3-D Hall sensor with new structures. We have increased the sensitivity about 6 times to form the trench using anisotropic etching. And we have increased the sensitivity for the $B_z$ by 80 % compared with those of $B_x$ and $B_y$ using deposition of the ferromagnetic thin films on the bottom surface of the wafer to concentrate the magnetic fluxes. Sensitivities of the fabricated sensor with Ni/Fe film for $B_x,\;B_y$, and $B_z$ were measured as 361mV/T, 335mV/T, and 286mV/T, respectively. It has also showed sine wave of Hall voltages over a $360^{\circ}$ rotation. A packaged sensing part was $1.2{\times}1.2mm^2$. The measured linearity of the sensor was within ${\pm}3%$ of error. Resolution of the fabricated sensor was measured by $1{\times}10^{-5}T$.

Nonrandom Combination of Fatty Acid and Alcohol Moieties in Wax Esters from Liza Carinata Roe (등줄숭어 란유의 Nonrandom 분포를 한 왁스에스테르 조성에 관한 연구)

  • Joh, Yong-Goe;Lee, Kyeong-Hee;Cho, Yeon-Joo
    • Korean Journal of Food Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.624-632
    • /
    • 1989
  • Lipids of Liza carinata roe were extracted and separated into detailed lipid classes by column chromatography. About 57-62% of the total lipids consisted of wax esters in which saturated and unsaturated fatty alcohols combined with fatty acids with up to six double bonds. Between the even-numbered wax ester peaks in gas-liquid chromatography, ones with odd chain lengths such as C31, C33 and C35 were eluted in appreciable amounts. Isomers composed of different fatty acids and alcohols at a given chain length were not resolved on 1.5% OV-17 column. The principal component of wax esters in sample A were C32, C34 and C30 (45.0%, 19.2%, and 12.2%), followed by C36 and C38 length (9.5% and 4.7%), while those in sample B were mainly occupied by C34, C32 and C36 length (36.3%, 31.4% and 14.5%) with minor components C30 and C38 length (5.2%, and 3.4%). The wax esters were not a random combination of constituent fatty acids and alcohols. With increase in boiling temperature the wax esters increased slightly in viscosity over the unboiled, showing a tendency toward randomness, and finally were completely randomized at $360^{\circ}C$ for 40 minutes. The enzymes involved in wax ester biosynthesis seemed to have high selectivity for chain length of fatty acids and alcohols.

  • PDF

Vacuum Stripping of $CO_2$ from Aqueous MEA Solutions Using PDMS-PE Composite Membrane Contactor (MEA 수용액으로부터 PDMS-PE 복합막 접촉기를 이용한 이산화탄소 감압탈거)

  • Kim, Jeong-Hoon;Ahn, Hyo-Seong;Kim, Jeong-Hoon
    • Membrane Journal
    • /
    • v.22 no.1
    • /
    • pp.46-53
    • /
    • 2012
  • Low-temperature carbon dioxide stripping by a vacuum membrane stripping technology was studied as a substitute for the stripping process in a conventional aqueous amine process. Composite membranes with $5{\mu}m$ thickness of PDMS (polydimethylsiloxane) dense layer on a PE (polyethylene) support layer were prepared by a casting method and used as a membrane contactor for $CO_2$ stripping. Aqueous amine solutions of 30 wt% MEA (monoethanolamine) were used as absorbents. $CO_2$ flux was examined under various operating conditions by varying the vacuum pressure (60~360 mmHg (abs.)), stripping temperature ($25{\sim}80^{\circ}C$), $CO_2$ loading (0.5~0.7). $CO_2$ stripping flux increased with increasing temperature and $CO_2$ loading as well as decreasing vacuum pressure. PDMS-PE composite membrane has stability for vacuum stripping process compared with PTFE porous membrane.

The Interesting Moving Objects Tracking Algorithm using Color Informations on Multi-Video Camera (다중 비디오카메라에서 색 정보를 이용한 특정 이동물체 추적 알고리듬)

  • Shin, Chang-Hoon;Lee, Joo-Shin
    • The KIPS Transactions:PartB
    • /
    • v.11B no.3
    • /
    • pp.267-274
    • /
    • 2004
  • In this paper, the interesting moving objects tracking algorithm using color information on Multi-Video camera is proposed Moving objects are detected by using difference image method and integral projection method to background image and objects image only with hue area, after converting RGB color coordination of image which is input from multi-video camera into HSI color coordination. Hue information of the detected moving area are normalized by 24 steps from 0$^{\circ}$ to 360$^{\circ}$ It is used for the feature parameters of the moving objects that three normalization levels with the highest distribution and distance among three normalization levels after obtaining a hue distribution chart of the normalized moving objects. Moving objects identity among four cameras is distinguished with distribution of three normalization levels and distance among three normalization levels, and then the moving objects are tracked and surveilled. To examine propriety of the proposed method, four cameras are set up indoor difference places, humans are targeted for moving objects. As surveillance results of the interesting human, hue distribution chart variation of the detected Interesting human at each camera in under 10%, and it is confirmed that the interesting human is tracked and surveilled by using feature parameters at four cameras, automatically.

Accuracy Improvement of Laser Navigation System using FIS and Reliability (FIS와 신뢰도를 이용한 레이저 내비게이션의 정밀도 향상)

  • Jung, Eun-Kook;Kim, Jung-Min;Jung, Kyung-Hoon;Kim, Sung-Shin
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.21 no.3
    • /
    • pp.383-388
    • /
    • 2011
  • This paper presents to study the accuracy improvement of the laser navigation using FIS(fuzzy inference system) and the reliability. As wireless guidance system, the top-mounted laser with the laser navigation can rotate $360^{\circ}$ with phototransistor or other optical sensors that read the return signal from reflectors mounted at the perimeter of the workspace. The type of major existing guidance systems is a wire guidance system. Because they have high accuracy and fast response time, they are used to most industries. However, their installation cost is very expensive and maintenance is very difficult because their sensors are placed approximately 1 inch below the ground or embedded in the floor. To solve those problems, the laser navigation was developed as a wire guidance system. It does not need to reconstruct a floor or ground. And it can reduce costs of installation and maintenance because changing the layout is easy. However, it is difficult to apply to an industrial field because it is easily affected by disturbances which cause loss and damage of data, and has slow respond time. Therefore, we study the accuracy improvement of the laser navigation. The proposed method is a correction method using reliability of the laser navigation. here, reliability is calculated by FIS which is designed with the analyzed characteristics of the laser navigation. For performance comparison, we use original position data form the laser navigation and position data corrected by original reliability from the laser navigation. In experimental result, we verified that the performance of the proposed method compared the others is improved by about 50% or more.