• Title/Summary/Keyword: ${99m}^Tc$

Search Result 1,347, Processing Time 0.028 seconds

Comparison of the Results for Sentinel Lymph Node Mapping in the Breast Cancer Patients using $^{99m}Tc$-Antimony Trisulfide Colloid, $^{99m}Tc$-Tin Colloid, and $^{99m}Tc$-Human Serum Albumin (유방암 환자에서 $^{99m}Tc$-Antimony Trisulfide Colloid, $^{99m}Tc$-Tin Colloid, $^{99m}Tc$-Human Serum Albumin을 이용한 감시림프절 매핑 성적의 비교)

  • Jang, Sung-June;Moon, Seung-Hwan;Kim, Seok-Ki;Kim, Bom-Sahn;Kim, Seok-Won;Chung, Ki-Wook;Kang, Keon-Wook;Lee, Eun-Sook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.6
    • /
    • pp.546-552
    • /
    • 2007
  • Purpose: In the breast cancer patient, lymphatic mapping and sentinel lymph node biopsy are the most important procedure for axillary lymph node staging. We aimed to compare the three radiocolloids [$^{99m}Tc$-antimony trisulfide colloid (ASC), $^{99m}Tc$-tin colloid (TC), and $^{99m}Tc$-human serum albumin (HSA)] for sentinel lymph node mapping. Subjects and Methods: Totally, 397 patients with clinically N0 stage were enrolled. $^{99m}Tc$-ASC was injected in 202 out of 397 patients, $^{99m}Tc$-TC was injected in 120 patients, and $^{99m}Tc$-HSA was injected in the remaining 75 patients. The sentinel lymph nodes were localized by lymphoscintigraphy and selected using intraoperative gamma probe. All sentinel lymph nodes were investigated by intraoperative pathologic consultation. The axillary lymph nodes which were harvested by the lymph node dissection were also investigated. Results: The patients of each group showed similar clinical characteristics. There were no significant differences (p>0.05) in the identification rate of sentinel lymph nodes (IR), false negative rate (FNR), and negative predictive value (NPV). The axillary lymphadenectomy revealed axillary lymph node metastases in those three groups (ASC-33.2%, TC-31.7%, HSA-22.7%). The IR, FNR, and NPV were not significantly different among those groups. Conclusion: Those three $^{99m}Tc$-labeled radiocolloids showed equivalent results in sentinel lymph node mapping of breast cancer.

Diagnostic Role of Tc-99m MIBI Scintimammography in Suspected Breast Cancer Patients: Results of Unicenter Trial (유방암이 의심되는 환자에서 Tc-99m MIBI 유방스캔의 진단적 역할: 단일기관의 결과)

  • Kim, Seong-Jang;Kim, In-Ju;Kim, Yong-Ki;Bae, Young-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.3
    • /
    • pp.234-242
    • /
    • 2000
  • Purpose: Tc-99m MIBI scintimammography has been validated as an useful non-invasive diagnostic tool for the primary breast cancer. But most studies have included small population of patients. We have experienced a large study population and investigated the diagnostic usefulness of Tc-99m MIBI scintimammography in detection of primary breast cancer and axillary lymph node metastasis. Materials and Methods: This study included 305 patients who underwent scintimammogtaphy for palpable breast masses or abnormal radiologic findings. Tc-99m MIBI scintimammography was performed 10 minutes after intravenous injection of 925 MBq of Tc-99m MIBI. If the early image revealed abnormal finding, 3 hour delayed image was also acquired. We calculated early and delayed lesion to non-lesion ratios (L/N). The pathologic diagnosis was obtained from surgical operation or FNAB and compared with the results of Tc-99m MIBI scintimammography. Results: Malignant breast diseases were 155 and benign ones were 150. Tc-99m MIBI scintimammography revealed 132 true positive, 23 false negative, 10 false positive, and 140 true negative cases. The sensitivity, specificity, positive predictive value and negative predictive value for the primary breast cancer detection were 85.2%, 93.4%, 92.9%, and 85.9%, respectively. The sensitivity, specificity, positive predictive and negative predictive values of Tc-99m MIBI scintimammography in detecting metastatic axillary lymph node involvement were 22%, 90.4%, 61.9% and 62.3%, respectively. Early L/N of malignant breast disease was significantly higher than that of benign one ($2.44{\pm}0.97\;vs\;1.94{\pm}0.78$, p=0.01). Delayed L/N had no significant difference between malignant and benign breast diseases ($1.94{\pm}0.52\;vs\;1.91{\pm}0.73$, p=0.43). Conclusion: Our study revealed that Tc-99m MIBI scintimammography was an useful diagnostic tool for the diagnosis of breast cancer. And early L/N ratio might provide complementary role in the detection of breast cancer. But the Tc-99m MIBI scintimammography had limited value in the detection of small breast cancer (less than 1 cm) and axillary lymph node metastasis.

  • PDF

Optimization of Correction Factor for Linearization with Tc-99m HM PAO and Tc-99m ECD Brain SPECT (Tc-99m HMPAO와 Tc-99m ECD 뇌SPECT의 뇌혈류량 정량화에 사용되는 Linearization Algorithm의 Correction Factor 조사)

  • Cho, Ihn-Ho;Hayashida, Kohei;Won, Kyu-Chang;Lee, Hyoung-Woo;Watabe, Hiroshi;Kume, Norihiko;Uyama, Chikao
    • Journal of Yeungnam Medical Science
    • /
    • v.16 no.2
    • /
    • pp.237-243
    • /
    • 1999
  • We conducted this study to find the optimal correction factor(${\alpha}$) of Lassen's linearization algorithm which has been applied for correction of flow-limited uptake at a high flow range in $^{99m}Tc$ d,l-hexamethylpropy leneamine oxime(HMPAO) and $^{99m}Tc$ ethyl cysteinate dimer(ECD). Ten patients with chronic cerebral infarction were involved in this study. We obtained the corrected $^{99m}Tc$ HMPAO and $^{99m}Tc$-ECD brain SPECT(single photon emission computed tomography) using the algorithm with ${\alpha}$ values that varied from 0.1 to 10 and compared the results with regional cerebral blood flow determined by positron emission tomography (PET-rCBF). The multi-modal volume registration by maximization of mutual information was used for matching between PET-rCBF and SPECT images. The highest correlation coefficient between $^{99m}Tc$-HMPAO and $^{99m}Tc$-ECD brain uptake and PET-rCBF was revealed at ${\alpha}$ 1.4 and 2.1, respectively. We concluded that the ${\alpha}$ values of Lassen's linearization algorithm for $^{99m}Tc$-HMPAO and $^{99m}Tc$-ECD brain SPECT images were 1.4 and 2.1, respectively to indicate cerebral blood flow with comparison of PET-rCBF.

  • PDF

Comparison of Direct-labeling Method of Antibody with $^{99m}Tc$ and $^{188}Re$ (농양이식백서에서 $^{99m}Tc,\;^{188}Re$ 직접표지항체의 비교)

  • Choi, Tae-Hyun;Lim, Sang-Moo;Choi, Chang-Woon;Woo, Kwang-Sun;Chung, Wee-Sup;Lim, Soo-Jeong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.84-93
    • /
    • 1999
  • Purpose: We investigated the direct labeling method of antibody with $^{99m}Tc$ and $^{188}Re$ and examined the stability and function of these labeled compounds in in vitro and in vivo. Materials and Methods: Disulfide bond of nonspecific human IgG was reduced to -SH group by 2-mercaptoethanol. Stannous ion was used to reduce $^{99m}Tc$ and $^{188}Re$. The stability of $^{99m}Tc$-IgG and $^{188}Re$-IgG was estimated upto 24 hrs. Biodistribution was evaluated in abscess bearing rats at 4 and 24 hr post-injection of $^{99m}Tc$ or $^{188}Re$ labeled IgG. Results: The number of -SH group per reduced IgG molecule was 2.34. The labeling yield of $^{99m}Tc$-IgG and $^{188}Re$-IgG were 90% and 95%, respectively The stability of $^{99m}Tc$-IgG at 1, 4, 6 and 24 hr was 91%, 83%, 78%, 7% and that of $^{188}Re$-IgG at 1, 4, 16 and 24 hr was 94%, 80%, 47%, 42%, respectively. At 4 hr post-injection of $^{99m}Tc$-IgG, high uptake was found on kidney, blood, stomach and abscess ($9.42{\pm}0.68,\;1.43{\pm}0.24,\;0.86{\pm}0.18,\;0.72{\pm}0.10$ %ID/g, respectively). The uptakes at 24 hr were kidney, abscess,.itomach, and blood in descending order. In case of $^{188}Re$-lgG, high uptake at 4 hr post injection appeared on kidney, blood, abscess and stomach ($3.92{\pm}0.62,\;1.32{\pm}0.08,\;0.88{\pm}0.01,\;0.26{\pm}0.06$, respectively). The uptakes at 24 hr were kidney, abscess, blood and stomach in descending order. The abscess to blood uptake ratio of $^{99m}Tc$-IgG was 0.5 at 4 hr and 2.02 at 24 hr and that of $^{188}Re$-IgG was 0.67 and 1.29. Conclusion: $^{99m}Tc$-IgG and $^{188}Re$-IgG canbe labeled efficiently with direct labeling method. However, $^{99m}Tc$-IgG and $^{188}Re$-IgG, labeled with direct method, was unstable. Further study is needed to enhance the stability of the antibody labeling.

  • PDF

Comparison of Thallium-201 Scan and Tc-99m Sestamibi Scan in the Differential Diagnosis of Breast Mass (유방암 진단에 있어서 탈륨스캔과 Tc-99m MIBI 스캔의 비교)

  • Cho, Ihn-Ho;Won, Kyu-Jang;Lee, Hyung-Woo;Lee, Soo-Jung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.76-83
    • /
    • 1999
  • Purpose: We performed this study to compare T1-201 and Tc-99m MIBI scans for the differentiation of malignant from benign breast mass. Materials and Methods: Thirty-eight female patients underwent T1-201 breast scan and thirty-two of them also underwent Tc-99m MIBI scan of the breast. After intravenous injection of 74-111 MBq of T1-201, early (10 minutes) and delayed (3 hours) images were obtained. Then, 555-740 MBq of Tc-99m MIBI was injected and images after 30 minutes were obtained. We compared T1-201 and Tc-99m MIBI scans with pathologic results. Results: Twenty-three patients were confirmed to have infiltrating duct carcinoma and fifteen patients to have benign breast mass by excisonal biopsy. The sensitivity of early and delayed T1-201 scan and Tc-99m MIBI scan in the detection of malignant breast lesion were 100% (23/23), 82% (18/22), and 90% (18120), respectively. The sensitivity of early T1-201 scan was significantly higher than that of delayed T1-201 scan (p<0.05). The specificity of early and delayed T1-201 scan and Tc-99m MIBI scan were 73% (l1/15), 73% (l1/15) and 83% (10/12), respectively (p: not significant). Three patients out of nine with fibroadenoma and one patient with atypical duct hyperplasia were false positive in both early and delayed T1-201 scans. The size of fibroadenoma with false positive in early and delayed T1-201 scan (4 cases) was larger than that of 11 fibroadenoma with true negative scan (p<0.01). Metastatic axillary lymph node involvement was present in fifteen patients. The sensitivity to detect metastatic nodes was 38% (5/13) for early T1-201 images, 15% (2/13) for delayed T1-201 images, 58% (7/12) for Tc-99m MIBI planar images and 67% (4/6) for Tc-99m MIBI SPECT. The sensitivity of Tc-99m MIBI planar or SPECT was significantly higher than that of delayed T1-201 images (p<0.05). Conclusion: Early T1-201 and Tc-99m MIBI scan are useful noninvasive methods to differentiate malignant from benign mass of breast Tc-99m MIBI scan was sensitive in detecting axillary lymph node metastasis in patients with breast cancer.

  • PDF

Is the Renal Uptake of $^{99m}Tc$-DMSA Decreased in Microalbuminuric Diabetic Patient? (미세 단백뇨기의 당뇨병 환자에서 $^{99m}Tc$-DMSA 신섭취율은 감소하는가?)

  • Kim, Seong-Jang;Kim, In-Ju;Kim, Yong-Ki
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.398-404
    • /
    • 1999
  • Purpose: Diabetic nephropathy is the most common cause of end stage renal disease and the incidence is progressively increasing. The aim of this study was to investigate the differences of $^{99m}Tc$-DMSA renal uptake among diabetic patients with normoalbuminuria, microalbuminuria and overt proteinuria, and then to determine the clinical usefulness of $^{99m}Tc$-DMSA in predicting early diabetic nephropathy Materials and Methods: $^{99m}Tc$-DMSA scan was performed and a total renal uptake of $^{99m}Tc$-DMSA was measured in 145 diabetic patients. Patients were divided into 3 groups according to the amount of 24 hour urinary albumin excretion as Group I (normoalbuminuria, 74 cases), Group II (microalbuminuria, 39 cases), and Group III (overt proteinuria, 32 cases). The differences of $^{99m}Tc$-DMSA renal uptake among the 3 groups and the correlation between the renal uptake of $^{99m}Tc$-DMSA and other clinical parameters were analyzed. Results: The total renal uptake of $^{99m}Tc$-DMSA of Group II ($40.8{\pm}11.0%$) was significantly lower than that of Group I ($54.4{\pm}6.3%$, p<0.001). The uptake of Group III ($27.7{\pm}12.0%$) was significantly lower than those of both Group I and Group II (p<0.001). $^{99m}Tc$-DMSA total renal uptakes correlated negatively with serum creatinine level (r=-0.629, p<0.001) and positively correlated with creatinine clearance rate (r=0.102, p<0.001). Conclusion: $^{99m}Tc$-DMSA total renal uptake of diabetic patients with microalbuminuria was significantly decreased compared with that of patients of normoalbuminuria. Therefore, $^{99m}Tc$-DMSA scan can be used as a diagnostic study for early detection of the diabetic nephropathy.

  • PDF

Uptake of 99mTc-DISIDA in Primary Hepatocellular Carcinoma and Metastatic Nodule in the Lung (Tachnetium-99m DISIDA Scan으로 확인된 간외전이성 간세포암 1례)

  • Do, Jun-Young;Lee, Heon-Ju;Choi, Soo-Bong;Lee, Hyun-Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.5 no.2
    • /
    • pp.171-174
    • /
    • 1988
  • Recently, several reports of extrahepatic hepatocellular carcinoma metastasis demonstrated by technetium- 99mTc-IDAs scan have shown that 99mTc-IDA s can be used to detect extrahepatic metastasis in hepatocellular carcinoma. We report here a case of hepatocellular carcinoma with pulmonary nodules that were demonstrated as metastasis in nature by the use of the 99mTc-DISIDA. The findings in this case and several reports reviewed here suggest that the 99mTc-DISIDA scan may be a useful diagnostic agent that can detect the extrahepatic metastasis of hepatocellular carcinoma and stage the disease. But more clinical study in needed to establish the position of 99mTc-DISIDA in the field of diagnosis of extrahepatic hepatocellular carcinoma.

  • PDF

Study on Labeling Efficiency of $^{99m}Tc$-HMPAO ($^{99m}Tc$-HMPAO 표지효율에 대한 고찰)

  • Hyeon, Jun Ho;Lim, Hyeon Jin;Kim, Ha Kyun;Cho, Seong Uk;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.131-134
    • /
    • 2012
  • Purpose : The labeling efficiency of radiopharmaceuticals in nuclear medicine is important in terms of accuracy and reliability of the examination. Usually $^{99m}Tc$-HMPAO used for brain SPECT scan is chemically unstable since lots of impurities are existing. Therefore, occurrence of loss of labeling efficiency is easy to appear. In this paper, labeling and use of $^{99m}Tc$-HMPAO should be helpful through experiments on factors affecting the labeling efficiency of $^{99m}Tc$-HMPAO. Materials and Methods : Domestic HMPAO vials (Dong-A) used for brain SPECT scan were tested. Domestic Samyeong Generator 55.5 GBq (1,500 mCi), TLC measurement sets (ITLC-SG, butanone, saline, TLC chamber) and radio-TLC scanner (Advantest, Bioscan) were used. In the first experiment, after eluting generator at 1, 8, 16, 24, 28 hours apart, each eluted $^{99m}Tc$-pertechnetate were labeled with HMPAO and the labeling efficiency was measured. In the second experiment, after eluting $^{99m}Tc$-pertechnetate from a generator, $^{99m}Tc$-pertechnetate was drawn at 0, 1, 3, 6 hours. And each drawn $^{99m}Tc$-pertechnetate were labeled with HMPAO for measuring labeling efficiency. In the third experiment, labeling efficiency was measured at 0, 0.5, 3, 5, 7 hours after labeling $^{99m}Tc$-HMPAO. Results : In the first experiment, measured values were appeared 95.05, 94.64, 94.94, 95.64, 96.76% in passing order of time. In the second experiment, measured values were appeared 94.38, 94.23, 93.26, 91.03% in passing order of time. In the third experiment, measured values were appeared 95.76, 94.17, 88.19, 83.6, 76.86% in passing order of time. Conclusion : In the first experiment of this paper, labeling efficiency of $^{99m}Tc$-HMPAO labeled with $^{99m}Tc$-pertechnetate eluted after 24 hours from first elution. Additional experiments will be needed to discuss for usability. In the second experiment, the labeling efficiency was slightly decreased in chronological order, but it was measured higher than 90%. Also, additional experiments will be needed to discuss for usability. In the third experiment, the labeling efficiency was decreased considerably. Especially, within 3 hours after the labeling is recommended to use $^{99m}Tc$-HMPAO

  • PDF

Usefulness of Tc-99m MIBI Scan in the Postoperative Follow Up Of Well-Differentiated Thyroid Cancer (분화된 갑상선암의 수술후 경과 관찰에서 Tc-99m MIBI 스캔과 다른 추적 지표들의 유용성 비교)

  • You, Kye-Hwa;Song, Jae-Soon;Shinn, Joon-Jae;Lee, Hyun-Kyung;Cha, Wang-Ki;Kim, Do-Min;Kim, Eun-Sil;Kim, Chong-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.356-364
    • /
    • 1997
  • To evaluate the clinical utility of Tc-99m MIBI scan in the detection of residual thyroid tissue or metastatic lesion in postoperative thyroid cancer patients, we compared Tc-99m MIBI scan with I-131 diagnostic and therapeutic scan in 30 postoperative well-differentiated thyroid cancer patients. Thyroglobulin levels of both on and off thyroid hormone medication and antithyroglobulin antibody were tested [Tg(on), Tg(off)]. Positive rates for I-131 diagnostic and Tc-99m MIBI scan were 81% and 68% respectively. Concordance between I-131 diagnostic and Tc-99m MIBI scan was observed in 15 cases; 12 positive and 3 negative respectively. Among the 6 cases with negative I-131 diagnostic scan and positive Tc-99m MIBI scan, 4 were Positive in the therapeutic I-131 scan We concluded that Tc-99m MIBI scan maybe a useful complementary modality to the currently established method of I-131 scan and serum thyroglobulin level in the detection of recurrent or metastatic thyroid cancer, especially in the case of negative I-131 diagnostic scan.

  • PDF

Polymer Formation and Altered Biodistribution of IgG Labeled with $^{99m}Tc$ and Cyclic DTPA (항체의 Cyclic DTPA를 이용한 $^{99m}Tc$ 표지시 Polymer 형성과 체내 동태 변화)

  • Lim, Sang-Moo;Woo, Kwang-Sun;Chung, Wee-Sup;Awh, Ok-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.270-276
    • /
    • 1993
  • $Technetium-^{99m}$ labeling method using bifunctional chelating agent cyclic DTPA has been evaluated with human polyclonal nonspecific IgG. IgG was conjugated with cyclic DTPA with various molar ratio. Reduction of $^{99m}Tc$ was done with $Na_2S_2O_4$ with various molar excess. Labeling efficiency and identification of polymer was confirmed with HPLC using TSK4000 SW column. Polymer was purified with 100 cm Sepharose 6LB column. Cultured $1{\times}10^9$ Staphylococcus aureus were injected into rat thigh 24 hours later labeled IgG was injected, and in vivo distribution was observed 4 and 24 hours thereafter. Reduction of $^{99m}Tc$ was optimal with the 10000-50000 times molar excess of $Na_2S_2O_4$. Polymer formation increased with increasing mloar excess of cyclic DTPA to IgG. Three step labeling-labeling DTPA conjugated IgG after reduction of $^{99m}Tc$-made more polymer than two two step labeling-simultaneous mixing DTPA conjugated IgG, $^{99m}Tc$ and $Na_2S_2O_4$. $^{99m}Tc$ blood clearance and lower uptake in the abscess and other organs. IgG conjugated with 200 times molar excess of cyclic DTPA showed slower blood clearance with 200 times molar excess of cyclic DTPA showed slower blood clearance than that of 200 times molar excess of cyclic DTPA showed slower blood clearance than that of 20 times molar excess. In the $^{99m}Tc$ labeling of IgG with cyclic DTPA for the immunoscintigraphy, obtimal labeling condition should be chosen, and effect of the $^{99m}Tc$ labeled IgG polymer should be considered.

  • PDF