• Title/Summary/Keyword: ${\mu}$-PIV

Search Result 51, Processing Time 0.027 seconds

Hemodynamic Analysis of Blood Flows in the Extraembryonic Blood Vessels of Chicken Embryos (유정란 태아외부혈관 내부 혈액유동에 대한 혈류역학적 연구)

  • Lee, Jung-Yeop;Lee, Sang-Joon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.6-9
    • /
    • 2008
  • Analyzing the characteristics of blood flow in the blood vessels is very important to diagnose the circulatory diseases. In order to investigate the hemodynamic characteristics in vivo, the measurements of blood flows inside the extraembryonic arterial and venous blood vessels of chicken embryos were carried out using an in vivo micro-PIV technique. The circulatory diseases are closely related with the formation of abnormal hemodynamic shear stress regions, thereby it is important to get blood velocity and vessel's morphological information according to the vessel configuration and the flow conditions. In this study, the flow images of RBCs in blood vessels were obtained using a high-speed CMOS camera with a spatial resolution of approximately 14.6${\mu}$m${\times}$14.6${\mu}$m in the whole circulation network of blood vessels. The blood flows in the veins and arteries show steady laminar and unsteady pulsatile flow characteristics, respectively. The mean blood flows merged (in veins) and bifurcated (in arteries) smoothly into the main blood vessel and branches, respectively, without any flow separation or secondary flow which accompanying large variation of shear stress. Vorticity was high in the inner regions for both types of vessels, where the radius of curvature varied greatly. The instantaneous flows in the arterial blood vessels showed noticeable pulsatility due to the heart beat, and the main features of the velocity waveforms, including pulsatile shape, retrograde flow, mean velocity, maximum velocity and pulsatile frequency, were significantly dependent on the pulsatile condition which dominates the arterial blood flow. In near future, these in vivo experimental results of blood flow measured in various extraembryonic blood vessels would be very useful to understand the hemodynamic characteristics of human blood flows and various blood flow researches for clinically useful hemodynamic discoveries as well.

  • PDF

Dynamic Characterization of Passive Flow-Rate Regulator Using Pressure-Dependent Autonomous Deflection of Parallel Membrane Valves (압력에 따른 평행박막 밸브의 자율 변형을 이용한 수동형 유량 제어기의 동적특성 평가)

  • Doh, Il;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.8
    • /
    • pp.825-829
    • /
    • 2011
  • We performed a dynamic characterization of passive flow-rate regulators, which compensate for inlet pressure variation and maintain a constant flow rate for precise liquid control in microfluidic systems. To measure the flow rate for a short time, much less than the period of the dynamic inlet pressure, we use the particle image velocimetry (PIV) method. DI water containing fluorescent beads with a $0.7-{\mu}m$ diameter was supplied to the flow-rate regulators, and two successive images of the particles were taken by a pulse laser and a fluorescent microscope to measure the flow velocity. For a dynamic inlet pressure of frequency 60 Hz, the flow velocity was constant with an average of 0.194 ${\pm}$ 0.014 m/s as the inlet pressure varied between 20 kPa to 50 kPa. The flow-rate regulators provided a constant flow rate of $5.82{\pm}0.29\;{\mu}l/s$ in the frequency range of the inlet pressure from 1 Hz to 60 Hz.

SPRAY STRUCTURE OF HIGH PRESSURE GASOLINE INJECTOR IN A GASOLINE DIRECT INJECTION ENGINE

  • Lee, Chang Sik;Chon, Mun Soo;Park, Young Cheol
    • International Journal of Automotive Technology
    • /
    • v.2 no.4
    • /
    • pp.165-170
    • /
    • 2001
  • This study is focussed on the investigation of spray characteristics from the high pressure gasoline injector for the application of gasoline direct injection engine. For the analysis of spray structure of high pressure gasoline injector; the laser scattering method with a Nd-Yag laser and the Phase Doppler particle analyzer system were applied to observe the spray development and the measurement of the droplet size and velocity of the spray, respectively. Also spatial velocity distribution of the spray droplet was measured by use of the particle image velocity system. Experimental results show that high pressure gasoline injector shapes the hollow-cone spray, and produce the upward ring shaped vortex on the spray surface region. This upward ring shaped vortex promotes the secondary atomization of fuel droplets and contributes to a uniform distribution of fuel droplets. Most of fuel droplets are distributed under 31$\mu m$ of the mean droplet size (SMD) and the frequency distribution of the droplet size under 25$\mu m$ is over 95% at 7 MPa of injection pressure. According to the experimental results of PIV system, the flow patterns of the droplets velocity distribution in spray region are in good agreement with the spray macroscopic behaviors obtained from the visualization investigation.

  • PDF

Research of liquid-solid two phase flow in centrifugal pump with crystallization phenomenon

  • Liu, Dong;Wang, Ya-Yun;Wang, Ying-Ze;Wang, Chun-Lin;Yang, Min-Guan
    • International Journal of Fluid Machinery and Systems
    • /
    • v.7 no.2
    • /
    • pp.54-59
    • /
    • 2014
  • Particle Image Velocimetry combined with developed image processing method is adopted to study the liquid-solid two phase flow in the centrifugal pump impeller with crystallization phenomenon. The tracer particle is used to follow the liquid phase, which has the diameter between 8 to $12{\mu}m$. The crystal particle precipitates from the sodium sulfate solution does change the wavelength of the laser, and which has great laser scattering characteristics. The diameter of the crystal particle is larger than $20{\mu}m$. Through calculating the diameter of the particles in the image, the tracer particle and the crystal particle can be distinguished. By analyzing the experimental result, the following conclusion has been obtained. During the delay period, there is not any crystal particle and the pump performance has not been changed. As the crystallization process begins, the crystal nuclei appears from the supersaturation solution and grows larger with temperature decreasing, which has the tendency of moving towards the pressure side. The characteristics of liquid-solid two phase flow with crystallization phenomenon in the pump are obtained according to analysis of experimental results, and some guiding advices are presented to mitigate the crystallization phenomenon in pump impeller.

In-vivo Measurements of Blood Flow Characteristics in the Arterial Bifurcation Cascade Networks of Chicken Embryo (유정란 태아외부혈관의 단계적으로 분기되는 동맥 분지관 내부 혈액 유동특성의 in-vivo 계측)

  • Lee, Jung-Yeop;Lee, Sang-Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2006.12a
    • /
    • pp.121-124
    • /
    • 2006
  • The arteries are very important in cardiovascular system and easily adapt to varying flow and pressure conditions by enlarging or shrinking to meet the given hemodynamic demands. The blood flow in arteries is dominated by unsteady flow phenomena due to heart beating. In certain circumstances, however, unusual hemodynamic conditions cause an abnormal biological response and often induce circulatory diseases such as atherosclerosis, thrombosis and inflammation. Therefore quantitative analysis of the unsteady pulsatile flow characteristics in the arterial blood vessels plays important roles in diagnosing these circulatory diseases. In order to verify the hemodynamic characteristics, in-vivo measurements of blood flow inside the extraembryonic arterial bifurcation cascade of chicken embryo were carried out using a micro-PIV technique. To analyze the unsteady pulsatile flow temporally, the (low images of RBCs were obtained using a high-speed CMOS camera at 250fps with a spatial resolution of $30{\mu}m\times30{\mu}m$ in the whole blood vessels. In this study, the unusual flow conditions such as flow separation or secondary flow were not observed in the arterial bifurcations. However, the vorticity has large values in the inner side of curvature of vessels. In addition, the mean velocity in the arterial blood vessel was decreased and pulsating frequency obtained by FFT analysis of velocity data extracted in front of the each bifurcation was also decreased as the bifurcation cascaded.

  • PDF

Etiology and Clinical Features of Viral Lower-respiratory Tract Infections in Children in Winter, 2003 (2003년 겨울철 소아의 바이러스성 하기도 감염증에 대한 원인 및 바이러스별 임상양상)

  • Yun, Byung Ho;Lee, Hee Chul;Chun, Jung Mi;Yoon, So Young;Lee, Woo Gill;Shin, Son Moon
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.7
    • /
    • pp.723-730
    • /
    • 2005
  • Purpose : This study was performed to characterize the etiology and clinical features of acute viral lower-respiratory tract infections(LRI). Methods : Etiologic agents and clinical features of acute viral LRI were studied from October. 2003 through March. 2004 in hospitalized children with LRI(253 cases) at Samsung Cheil Hospital. The viruses were identified by indirect immunofluorescent method. Medical records of patients with proven viral LRI were reviewed retrospectively. Results : Ninety two cases(36.4%) were confirmed as viral infections. The identified pathogens were respiratory syncytial virus(RSV, 76.0%), adenovirus(ADV, 12.0%), influenza virus type A(INFA, 9.8 %), influenza virus type B(INFB, 1.1%) and parainfluenza virus(PIV, 1.1%). Eight four point eight% of patients were younger than 2 years of age. Clinical diagnosis of LRI were pneumonia(56.5%), bronchiolitis(35.9%), tracheobronchitis(4.3%) and croup(3.3%). The clinical symptoms and signs were cough(98.8%), rhinorrhea(82.6%), fever(70.7%), rale(67.4%), wheezing(29.3%), chest retraction(28.3%) and cyanosis(4.3%). The severe respiratory symptoms and signs were more common in RSV-infected patients, even cyanosis could be observed. Seventeen point four percent of patient had fever of $38.5^{\circ}C$ or higher and their most common etiologic agent was INFA(66.7%). Twenty three point nine percent had fever more than 5 days and common etiologic agent was INFA(77.8%). The elevated WBC count($>14{\times}10^3/{\mu}L$) was in 14.1%, and common etiologic agents were INFA(22.2%) and ADV(18.2%). C-reactive protein(CRP >4.0 mg/dL) was increased in 13.0%, and common in ADV(63.6 %). Increased aspartate aminotransferase(AST)/alanine aminotransferase(ALT) was detected in 10.9%, and the most common etiologic agent was RSV(12.9%). Conclusion : The common agents of acute viral LRI were RSV, ADV and INF, respectively. Because the etiologic agents present variable clinical features, it may be helpful to treat and to evaluate acute viral LRI that we should understand their etiologic variability.

Velocity Field Measurement of Flow Inside SNOUT of Zinc Plating Process ( I ) (용융아연 도금공정에서의 SNOUT 내부 유동장 해석 ( I ))

  • Shin, Dae Sig;Choi, Jayho;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.10
    • /
    • pp.1265-1273
    • /
    • 1999
  • PIV(Particle Image Velocimetry) velocity field measurements inside the snout of a1/10 scale model of the Zn plating process were carried out at the strip speed $V_s=1.5m/s$. Aluminum powder particles ($1{\mu}m$) and atomized olive oil ($3{\mu}m$) were used as seeding particles to simulate the molten Zinc flow and deoxidization gas flow, respectively. A pulsed Nd:Yag laser and a $2K{\times}2K$ high-resolution CCD camera were synchronized for the PIV velocity field measurement. From flow visualization study, it is found that the liquid flow in the Zn pot is dominantly governed by the uprising flow caused by the rotating sink roll, with its effect on the steel strip inside the snout largely diminished by installing of the snout. The deoxidization gas flow in front of the strip inside the snout can be characterized by a large-scale vortex rotating clockwise direction formed by the moving strip. In the rear side of the strip, a counter-clockwise vortex is formed and some of the flow entrained by the moving strip impinges on the free surface of molten zinc. The liquid flow in front of the strip is governed by the flow entering the snout, caused by the spinning sink roll. Just below the free surface a counter-clockwise vortex is formed near the snout wall. The moving strip affects dominantly the flow behind the strip inside the snout, and large amount of the liquid flow follows the moving strip toward the sink roll. The thickness of the flow following the strip is very thin in the front side due to the uprising flow, however thick boundary layer is formed in the rear side of the strip. Its thickness is increased as moving downstream toward the sink roll. Inside the snout, the deoxidization gas flow above the free surface is much faster than the liquid flow in the zinc pot. Due to the larger influx of the flow following the moving strip in the rear side of the strip, higher percentage of imperfection can be anticipated on the rear surface of the strip.

In-vitro Study on Hemorheological Behaviors of Blood Flow Through a Micro Tube (미세튜브 내부를 흐르는 혈액유동의 유변학적 특성에 대한 in-vitro 연구)

  • Kang, Myung-Jin;Ji, Ho-Seong
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.2
    • /
    • pp.99-105
    • /
    • 2010
  • In order to obtain velocity profile of blood flow with high spatial resolution, a micro PIV technique consisted of a fluorescent microscope, double-pulsed YAG laser, cooled CCD camera was applied to in-vitro blood flow experiment through a micro round tube of a diameter $100{\mu}m$. Velocity distributions of blood flow for rabbit were obtained. The viscosity profiles for shear rate were found at flowing condition. To provide hemorheological characteristics of blood flow, the viscosities for shear rate were evaluated. The viscosity of blood also steeply increase by decreasing shear rate resulting in Non-Newtonian flow, especially in low shear rate region caused by RBC rheological properties. The results show typical characteristics of Non-Newtonian characteristics from the results of velocity profile and viscosity for blood flow. From the inflection points, cell free layer and two-phase flow consisted with plasma and suspensions including RBCs can be separated.

The Development of a Benthic Chamber (BelcI) for Benthic Boundary Layer Studies (저층 경계면 연구용 Benthic chamber(BelcI) 개발)

  • Lee, Jae-Seong;Bahk, Kyung-Soo;Khang, Buem-Joo;Kim, Young-Tae;Bae, Jae-Hyun;Kim, Seong-Soo;Park, Jung-Jun;Choi, Ok-In
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.15 no.1
    • /
    • pp.41-50
    • /
    • 2010
  • We have developed an in-situ benthic chamber (BelcI) for use in coastal studies that can be deployed from a small boat. It is expected that BelcI will be useful in studying the benthic boundary layer because of its flexibility. BelcI is divided into three main areas: 1) frame and body chamber, 2) water sampler, and 3) stirring devices, electric controller, and data acquisition technology. To maximize in-situ use, the frame is constructed from two layers that consist of square cells. All electronic parts (motor controller, pA meter, data acquisition, etc.) are low-power consumers so that the external power supply can be safely removed from the system. The hydrodynamics of BelcI, measured by PIV (particle image velocimetry), show a typical "radial-flow impeller" pattern. Mixing time of water in the chamber is about 30 s, and shear velocity ($u^*$) near the bottom layer was calculated at $0.32\;cm\;s^{-1}$. Measurements of diffusivity boundary layer thickness showed a range of $180-230\;{\mu}m$. Sediment oxygen consumption rate, measured in-situ,was $84\;mmol\;O_2\;m^{-2}\;d_{-1}$, more than two times higher than on-board incubation results. Benthic fluxes assessed from in-situ incubation were estimated as follows: nitrate + nitrite = $0.18\;{\pm}\;0.07\;mmol\;m^{-2}\;d^{-1}$ ammonium $23\;{\pm}\;1\;mmol\;m^{-2}\;d^{-1}$ phosphate = $0.09\;{\pm}\;0.02\;mmol\;m^{-2}\;d^{-1}$ and silicate = $23\;{\pm}\;1\;mmol\;m^{-2}\;d^{-1}$.

Evaluation of Antibodies Against Haemophilus influenzae Type b in Korean Adults (우리나라 성인에서 Haemophilus influenzae type b에 대한 항체 평가)

  • Lee, Ji Hyen;Kim, Han Wool;Lee, Soyoung;Kim, Kyung-Hyo
    • Pediatric Infection and Vaccine
    • /
    • v.24 no.3
    • /
    • pp.125-133
    • /
    • 2017
  • Purpose: After the introduction of Haemophilus influenzae type b (Hib) vaccine in 1995 in Korea, it was included in the national immunization program in 2013. In the post-Hib vaccine era, some studies in other countries reported that invasive Hib disease affects adults, especially the elderly and immunocompromised persons, more often than it affects children. To evaluate disease susceptibility, quantitative and qualitative analysis of anti-polyribosylribitol phosphate (PRP) antibodies were carried out in Korean adults aged 20 to 85 years. Methods: Sera were collected from 39 healthy adults (20 to 50 years of age) and from 30 elderly adults (75 to 85 years of age) who did not have immune-compromising conditions. The concentration of anti-PRP immunoglobulin G (IgG) and serum bactericidal indices (SBIs) were measured by enzyme-linked immunosorbent assay and serum bactericidal assay. Results: Geometric mean concentrations of anti-PRP IgG and geometric mean SBIs were $0.88{\mu}g/mL$ (95% confidence interval [CI], 0.17 to 3.85) and 354 (95% CI, 50 to 2,499) in young adults and $1.67{\mu}g/mL$ (95% CI, 0.53 to 5.24) and 449 (95% CI, 146 to 1,376) in elderly adults, respectively. When the threshold of seropositivity for anti-PRP IgG was applied as 0.15 or $1.0{\mu}g/mL$, which is the protective antibody level in children, seropositive rates were 87.2% or 53.8% in young adults and 100% or 60% in elderly adults. The seropositivity rates of the SBI ($SBI{\geq}4$) were 82.1% and 100% in the groups, respectively. Conclusions: Most subjects in the adult and elderly adult groups display immunity to Hib based on quantitative and qualitative antibody levels, but not all. Because high immunization and low Hib circulation rates may reduce the natural Hib immunity in the population, monitoring Hib immunity as well as disease are needed continuously.