• Title/Summary/Keyword: ${\gamma}$-ray

Search Result 1,791, Processing Time 0.045 seconds

Growth and optical conductivity properties for MnAl2S4 single crystal thin film by hot wall epitaxy method (Hot Wall Epitaxy(HWE)법에 의한 MnAl2S4 단결정 박막 성장과 광전도 특성)

  • You, Sangha;Lee, Kijeong;Hong, Kwangjoon;Moon, Jongdae
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.24 no.6
    • /
    • pp.229-236
    • /
    • 2014
  • A stoichiometric mixture of evaporating materials for $MnAl_2S_4$ single crystal thin films was prepared from horizontal electric furnace. To obtain the single crystal thin films, $MnAl_2S_4$ mixed crystal was deposited on thoroughly etched semi-insulating GaAs(100) substrate by the Hot Wall Epitaxy (HWE) system. The source and substrate temperatures were $630^{\circ}C$ and $410^{\circ}C$, respectively. The crystalline structure of the single crystal thin films was investigated by the photoluminescence and double crystal X-ray diffraction (DCXD). The temperature dependence of the energy band gap of the $MnAl_2S_4$ obtained from the absorption spectra was well described by the Varshni's relation, $E_g(T)=3.7920eV-5.2729{\times}10^{-4}eV/K)T^2/(T+786 K)$. In order to explore the applicability as a photoconductive cell, we measured the sensitivity (${\gamma}$), the ratio of photocurrent to dark current (pc/dc), maximum allowable power dissipation (MAPD) and response time. The results indicated that the photoconductive characteristic were the best for the samples annealed in S vapour compare with in Mn, Al, air and vacuum vapour. Then we obtained the sensitivity of 0.93, the value of pc/dc of $1.10{\times}10^7$, the MAPD of 316 mW, and the rise and decay time of 14.8 ms and 12.1 ms, respectively.

A Study of Radiation Exposure in Proton Therapy Facility (양성자치료기 가속기 시설에서의 작업종사자의 방사선 피폭 연구)

  • Lee, Sang-Hoon;Shin, Dong-Ho;Yoon, Myong-Geun;Shin, Jung-Wook;Rah, Jeong-Eun;Kwak, Jung-Won;Park, Sung-Yong;Shin, Kyung-Hwan;Lee, Doo-Hyun;Ahn, Sung-Hwan;Kim, Dae-Yong;Cho, Kwan-Ho;Lee, Se-Byeong
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.37-42
    • /
    • 2009
  • Proton therapy facility, which is recently installed at National Cancer Center in Korea, generally produces a large amount of radiation near cyclotron due to the secondary particles and radioisotopes caused by collision between proton and nearby materials during the acceleration. Although the level of radiation by radioisotope decreases in length of time, radiation exposure problem still exists since workers are easily exposed by a low level of radiation for a long time due to their job assignment for maintenance or repair of the proton facility. In this paper, the working environment near cyclotron, where the highest radiation exposure is expected, was studied by measuring the degree of radiation and its duration for an appropriate level of protective action guide. To do this, we measured the radiation change in the graphite based energy degrader, the efficiency of transmitted beam and relative activation degree of the transmission beam line. The results showed that while the level of radiation exposure around cyclotron and beam line during the operation is much higher than the other radiation therapy facilities, the radiation exposure rate per year is under the limit recommended by the law showing 1~3 mSv/year.

  • PDF

The Role of Lymphocyte Compartment and Cytokine in Coal Workers Pneumoconiosis (진폐증환자에서의 임파구 분획 및 싸이토카인의 역할)

  • Lee, Jung-Yeon;Yoo, Kwang-Ha;Ahn, Hae-Ryon;Kim, Sung-Ryul;Lee, Hae-Woon;Ahn, Cheol-Min;Kim, Hyung-Joong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.3
    • /
    • pp.241-250
    • /
    • 2002
  • Background : Coal-worker's pneumoconiosis(CWP) is characterized by a chronic inflammatory lung reaction associated with macrophage accumulation in the alveolar spaces. CWP is usually divided into two stage : simple pneumoconiosis(SP) where there are a limited number of fibrotic lesions remain limited, with radiological opacities smaller than 1cm and progressive massive fibrosis(PMF), which is characterized by the development of a perifocal extensive fibrotic response of the lung and severe alterations in pulmonary function. In this study, the lymphocyte compartment and cytokine were evaluated by measuring the serum levels in the control, SP and PMF groups. Materials and Methods : The coal workers selected for this study were employees(patients?) of the Tae-Baek and Dong-Hae hospital. All were men, 45-76 years old and the mean duration of their exposure to coal dust was 23.2 years in the lymphocyte compartment and 24.3 years in the cytokine checked group. According to X-ray examination results, the patients were classified into either one of the SP, PMF categories. The normal controls examined were 26-70 years old men. The serum cytokine levels were estimated by using an end point enzyme immunoassay technique. Results : T lymphocyte, helper and suppressor T cells were highly related to pneumoconiosis in this study. A statistically significant decrease in the number of suppressor T lymphocytes was observed in the simple pneumoconiosis patients and at the same time, there was an increase in the lymphocyte index. Howevere, there was no statistically difference in the serum cytokines levels among the SP, PMF and control groups. Conclusion : T lymphocyte, helper T, and suppressor T cells may be highly related to the development of CWP compared to the control group particularly in the early stage of pneumoconiosis. The changes observed in the immunological system in patients with pneumoconiosis may lie at the bottom of the pathogenesis of fibrosis. Further study is needed to evaluate the lymphocyte compartment as a marker for pneumoconiosis development in the early stage.

Production and Assessing Usefulness of the Moving Phantom for Respiration Gated Radiotherapy (호흡동조 방사선치료용 팬텀의 제작 및 유용성 평가)

  • Lee, Yang-Hoon;Lee, Jae-Hee;Yoo, Suk-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.135-144
    • /
    • 2010
  • Purpose: The purpose of this study is that through production of phantom for respiration gated radiotherapy, assessing appropriacy of exposure dose for the therapy using RPM (Real-time Position Management). Materials and Methods: We located measurement object on the phantom for respiration gated radiotherapy made of 2 linear actuator, acrylic panel, stanchion, iron plate ets. to drive (up, down, front, back). Using 4D CT scan, we analyzed patient's respiration and reproduced the movement by computer. On the phantom, we located a 2D-Array (PTW) and an White water phantom (4.5 cm) and used DMLC (interval 2 cm) in the field size $10{\times}10\;cm$, then exposed 21EX X-ray 100 MU, in the case of phantom was (1) static (2) moving (3) gated using RPM respectively gantry $0^{\circ}$ and $90^{\circ}$ We measured with a 0.125 CC ionization chamber (PTW) on the phantom (7.5 cm) in the same condition. Results: Ionization chamber: There were within 0.3% of error with gating respiration and approximately 2% of error without gating in the same condition. 2D-Array: Gantry $90^{\circ}$, field size $10{\times}10\;cm$, using DMLC. There were within 3% of error with gating respiration and approximately 16% of error without gating. Conclusion: The phantom for respiration gated radiotherapy makes plans considering patient's movement, quantitative analysis of exposure dose and proper assessment therapy for IMRT patients using RPM possible.

  • PDF

Physical Dosimetry in Radioactive Iodine Treatment in the Patients with Thyroid Cancer (갑상선암 환자에 대한 방사성옥소 치료시 물리적 선량 측정)

  • Kim, Myung-Seon;Jeong, Nae-In;Lee, Jai-Yong;Kim, Chong-Soon;Kim, Chong-Ho;Lee, Myung-Chul;Koh, Channg-Soon;Kim, Hee-Geun;Kang, Duck-Won;Song, Myung-Jae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.124-132
    • /
    • 1994
  • Radioactive iodine has been widely used in patients with thyroid cancer combined with surgical treatment. However, due to individual variations in absorption and excretion and uptake by tumor tissue of radioactive iodine, there are differences in therapeutic effect and adverse effects even if the same doses are administrated. So this study compared the therapeutic effect and radiation hazard by measuring internal radiation dose. Of total 27 patients with well differentiated thyroid cancer who had been thyroidectomized, we administered radioactive iodine 100 mCi, 150 mCi, 200 mCi. According to BEL DOSIMETRY PROTO-COL, beta and gamma ray dose were estimated from a pelt of the logarithm of the percent of dose per liter of whole blood versus day, and percent dose retained versus day using somilogarithmic paper, respectively. 1) Physical dose to whole blood averaged $56.54{\pm}13.02$ rad in 100 mCi administered group, $76.83{\pm}19.97$ rad in 150 mCi administered group, $95.08{\pm}25.51$ rad in 200 mCi administered group and there has been a significant correlation among the groups. 2) Mean percent dose retained 48 hours later was 26.34%. 3) There was no significant correlation of physical dose between absence and presence of metastasis. 4) 17 of 19 patients who has been followed up with TSH and serum throglobulin, Thallium scan were successfully ablated by radioactive iodine. 5) Leukocyte, lymphocyte, neutrophil, platelet counts all deelined in 4.6 weeks and most of all were restored 3 months later. 6) There was no significant correlation between physical dosimetry and biologic dosimetry. Generally administered doses of radioactive iodine (100-200 mCi) to patients with thyroid cancer postoperatively had developed transient bone marrow suppression and minimal chromosomal aberration, but they were within safety dose to blood (200 rad). And there has been no significant differences in residual dose 48 hours later between Korean and western people.

  • PDF

Comparison of Collimator Choice on Image Quality of I-131 in SPECT/CT (I-131 SPECT/CT 검사의 에서 조준기 종류에 따른 영상 비교 평가)

  • Kim, Jung Yul;Kim, Joo Yeon;Nam-Koong, Hyuk;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.33-42
    • /
    • 2014
  • Purpose: I-131 scan using High Energy (HE) collimator is generally used. While, Medium Energy (ME) collimator is not suggested to use in result of an excessive septal penetration effects, it is used to improve the sensitivities of count rate on lower dose of I-131. This research aims to evaluate I-131 SPECT/CT image quality using by HE and ME collimator and also find out the possibility of ME collimator clinical application. Materials and Methods: ME and HE collimator are substituted as Siemens symbia T16 SPECT/CT, using I-131 point source and NEMA NU-2 IQ phantom. Single Energy Window (SEW) and Triple Energy Windows (TEW) are applied for image acquisition and images with CTAC and Scatter correction application or not, applied different number of iteration and sub set are reconstructed by IR method, flash 3D. By analysis of acquired image, the comparison on sensitivities, contrast, noise and aspect ratio of two collimators are able to be evaluated. Results: ME Collimator is ahead of HE collimator in terms of sensitivity (ME collimator: 188.18 cps/MBq, HE collimator: 46.31 cps/MBq). For contrast, reconstruction image used by HE collimator with TEW, 16 subset 8 iteration applied CTAC is shown the highest contrast (TCQI=190.64). In same condition, ME collimator has lower contrast than HE collimator (TCQI=66.05). The lowest aspect ratio for ME collimator and HE collimator are 1.065 with SEW, CTAC (+) and 1.024 with TEW, CTAC (+) respectively. Conclusion: Selecting a proper collimator is important factor for image quality. This research finding tells that HE collimator, which is generally used for I-131 scan emitted high energy ${\gamma}$-ray is the most recommendable collimator for image quality. However, ME collimator is also applicable in condition of lower dose, lower sensitive if utilizing energy window, matrix size, IR parameter, CTAC and scatter correction appropriately.

  • PDF

Application of PSL and TL Detection Method by Irradiation doses on the Foods Approved to Irradiation in Korea (조사 선량에 따른 품목별 PSL과 TL 시험법 적용 가능성 검증)

  • Cho, Joon-Il;Lee, Ji-Ae;Chung, Hyung-Wook;Lee, Soon-Ho;Hwang, In-Gyun
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.1
    • /
    • pp.43-48
    • /
    • 2010
  • This research was conducted to know application of Photostimulated luminescence (PSL) and Thermoluminesce(TL) methods by irradiation dose for leaching tea, sauces and starch approved in Korea. Leaching tea, sauces and starch powder were treated with $^{60}Co$ gamma ray at dose 0~10 kGy for detection trial whether they are irradiated or not by measuring PSL and TL for whole samples. PSL values were less than threshold value 700 and were, negative for non-irradiated samples but more than 5,000 and were positive for irradiated ones. PSL results of leaching tea and sauces showed the correct identification for non-irradiated and irradiated samples, respectively except starch samples. To enhance the reliability of the TL result, the first glow curve (TL1) was compared with the second glove curve (TL2) obtained after a re-irradiation step at 1 kGy. The TL ratio ($TL_1/TL_2$) was in good agreement with the reported TL threshold for both the non-irradiated (< 0.1) and irradiated (> 0.1) samples. TL results of leaching tea, sauces, starch showed the correct identification for non-irradiated and irradiated samples, respectively. This study was performed to know application of PSL and TL methods for leaching tea, sauces and starch, and the methods were able to detect the irradiation products.

Development of Saccharomyces cerevisiae Strains with High RNA Content (리보핵산을 다량으로 함유하는 Saccharomyces cerevisiae 균주의 개발)

  • Kim, Jae-Sik;Kim, Jin-Wook;Shim, Won;Min, Byoung-Cheol;Kim, Jung-Wan;Park, Kwan-Hwa;Pek, Un-Hua
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.465-474
    • /
    • 1999
  • RNase activity of Saccharomyces cerevisiae ATCC 7754 was investigated to obtain strains with high ribonucleic acid (RNA) content. The yeast strain contained two RNase activities; an acidic RNase with a optima of pH $3{\sim}4$ and an alkaline RNase with a optima pH 9. The acidic RNase activity was inhibited by $0.08\;M\;HgCl_{2}$ most drastically. The alkaline RNase activity was inhibited by 2.0 M NaCl or KCl, while enhanced by addition of $0.05\;M\;CaCl_{2},\;0.02\;M\;ZnSO_{4},\;or\;0.008\;M\;HgCl_{2}$. Various mutants of Saccharomyces cerevisiae ATCC 7754 were isolated by ethylmethane sulfonate (EMS) treatment or $\gamma$-ray/ultra violet irradiation. Among the mutants that were sensitive to high concentration of KCl which inhibits alkaline RNase, B24 was selected for high RNA content per culture volume. Growth characteristics of the mutant were comparable to those of the mother strain with optimum growth at pH $4.5{\sim}5.5$. The mutant accumulated higher content of RNA than the mother strain when glucose was used as the carbon source. However, both growth rate and total RNA content of the mutant were higher in molasses medium than in glucose medium. RNA content of the mutant increased rapidly during the early stage of growth, and then decreased gradually until the culture reached stationary phase by a fed-batch culture in a 5 L jar fermenter. Maximal cell harvest and the final RNA content using the mutant B24 were 69.6 g/L culture broth and 19.8 g/100 g of the dry cell while those using the mother strain were 68 g/L culture broth and 16.1 g/100 g of dry cell, respectively.

  • PDF

The development of conductive 10B thin film for neutron monitoring (중성자 모니터링을 위한 전도성 10B 박막 개발)

  • Lim, Chang Hwy;Kim, Jongyul;Lee, Suhyun;Jung, Yongju;Choi, Young-Hyun;Baek, Cheol-Ha;Moon, Myung-Kook
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.199-205
    • /
    • 2014
  • In the field of neutron detections, $^3He$ gas, the so-called "the gold standard," is the most widely used material for neutron detections because of its high efficiency in neutron capturing. However, from variable causes since early 2009, $^3He$ is being depleted, which has maintained an upward pressure on its cost. For this reason, the demands for $^3He$ replacements are rising sharply. Research into neutron converting materials, which has not been used well due to a neutron detection efficiency lower than the efficiency of $^3He$, although it can be chosen for use in a neutron detector, has been highlighted again. $^{10}B$, which is one of the $^3He$ replacements, such as $BF_3$, $^6Li$, $^{10}B$, $Gd_2O_2S$, is being researched by various detector development groups owing to a number of advantages such as easy gamma-ray discrimination, non-toxicity, low cost, etc. One of the possible techniques for the detection is an indirect neutron detection method measuring secondary radiation generated by interactions between neutrons and $^{10}B$. Because of the mean free path of alpha particle from interactions that are very short in a solid material, the thickness of $^{10}B$ should be thin. Therefore, to increase the neutron detection efficiency, it is important to make a $^{10}B$ thin film. In this study, we fabricated a $^{10}B$ thin film that is about 60 um in thickness for neutron detection using well-known technology for the manufacturing of a thin electrode for use in lithium ion batteries. In addition, by performing simple physical tests on the conductivity, dispersion, adhesion, and flexibility, we confirmed that the physical characteristics of the fabricated $^{10}B$ thin film are good. Using the fabricated $^{10}B$ thin film, we made a proportional counter for neutron monitoring and measured the neutron pulse height spectrum at a neutron facility at KAERI. Furthermore, we calculated using the Monte Carlo simulation the change of neutron detection efficiency according to the number of thin film layers. In conclusion, we suggest a fabrication method of a $^{10}B$ thin film using the technology used in making a thin electrode of lithium ion batteries and made the $^{10}B$ thin film for neutron detection using suggested method.

Morphological, Physiological andd Biochemical Characteristics of Early Senescence Mutant in Rice (Oryza sativa L) (벼의 조기노화 변이체의 형태, 생리 및 생화학적 특성)

  • 이숙영
    • Korean Journal of Plant Resources
    • /
    • v.8 no.3
    • /
    • pp.325-334
    • /
    • 1995
  • The early senescence mutant induced from Gihobyeo by $\gamma-ray$ irradiation was determined. The mutated gene expression was identified with comparing the characteristic of original cultivar. The mutant had so similar the morphological characteristics to original cultivar that it couldn't be distinguished until senescence occurred at about 20 days after heading. Suddenly yellow leaves were observed within a few days due to great decreases in total chlorophyll and various carotenoid contents. Transmission electron microscopy showed the formation of starch granules, distortion of fine structure of leaf cell organelles, especially grana structures, and the decrease in grain filled after senescence occurred. But banding patterns of total proteins and isozymes have not show any differences, The early senescence mutant will be very useful for study material not only on physiological and biochemical properties of plant senescence but also on gene expression regulating senescence which gives great influence on yield potential and its stability.

  • PDF