• Title/Summary/Keyword: $^{99m}Tc-MIBI$ Scintimammography

Search Result 14, Processing Time 0.02 seconds

A Study on Comparative Analysis of Mammography and Tc-99m MIBI Scintimammography for Dense Breast (치밀형 유방에서 유방특이감마영상검사의 유용성 평가)

  • Jeong, Eun-Mi;Kim, Ho-Seong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.76-79
    • /
    • 2012
  • Purpose: This study was to evaluate usefulness of $^{99m}Tc$-MIBI scintimammography for dense breast by comparing concordance in test results between Tc-99m MIBI scintimammography and mammography whose effect was proved the most as an imaging tool depending on breast density and at the same time by examining limitation on evaluation depending on density of breast tissue. [Materials and Methods] In the period from December 2010 to July 2011, this study targeted 150 patients who took both of $^{99m}Tc$-MIBI scintimammography and mammography conducted by using breast gamma camera in this hospital. Breast density was classified to the four levels of pattern 1~4 based on the results of mammography. $^{99m}Tc$-MIBI scintimammography was conducted with the LCC, the RCC, the LMLO, and the RML one minute after intravenous injection of 99mTc-MIBI 7400 MBq (20 mCi) while analysis was made for concordance in test results of $^{99m}Tc$-MIBI scintimammography and mammography. [Results] Among the 150 patients, pattern 1 was found in 3 patients, pattern 2 in 44 patients, pattern 3 in 61 patients, and pattern 4 in 37 patients. There were 5 patients who showed the case where it was impossible to determine density of breast tissue due to foreign body inserted to breast. The concordance ratio of the results between $^{99m}Tc$-MIBI scintimammography and mammography was 95.5% for pattern 2, 95.1% for pattern 3 and 94.6% for pattern 4. This demonstrated that the concordance rate decreased according to the increase in breast density. [Conclusion] When there was limitation on evaluation of breast specific gamma imaging test results due to increased intake in breast tissue or surgical site, the concordance rate was 6.8% for pattern 2, 16.3% for pattern 3 and 18.9% for pattern 4. This demonstrated that the degree of limitation on evaluation of breast specific gamma imaging test results increased according to the increase in breast density.

  • PDF

Diagnostic Role of Tc-99m MIBI Scintimammography in Suspected Breast Cancer Patients: Results of Unicenter Trial (유방암이 의심되는 환자에서 Tc-99m MIBI 유방스캔의 진단적 역할: 단일기관의 결과)

  • Kim, Seong-Jang;Kim, In-Ju;Kim, Yong-Ki;Bae, Young-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.3
    • /
    • pp.234-242
    • /
    • 2000
  • Purpose: Tc-99m MIBI scintimammography has been validated as an useful non-invasive diagnostic tool for the primary breast cancer. But most studies have included small population of patients. We have experienced a large study population and investigated the diagnostic usefulness of Tc-99m MIBI scintimammography in detection of primary breast cancer and axillary lymph node metastasis. Materials and Methods: This study included 305 patients who underwent scintimammogtaphy for palpable breast masses or abnormal radiologic findings. Tc-99m MIBI scintimammography was performed 10 minutes after intravenous injection of 925 MBq of Tc-99m MIBI. If the early image revealed abnormal finding, 3 hour delayed image was also acquired. We calculated early and delayed lesion to non-lesion ratios (L/N). The pathologic diagnosis was obtained from surgical operation or FNAB and compared with the results of Tc-99m MIBI scintimammography. Results: Malignant breast diseases were 155 and benign ones were 150. Tc-99m MIBI scintimammography revealed 132 true positive, 23 false negative, 10 false positive, and 140 true negative cases. The sensitivity, specificity, positive predictive value and negative predictive value for the primary breast cancer detection were 85.2%, 93.4%, 92.9%, and 85.9%, respectively. The sensitivity, specificity, positive predictive and negative predictive values of Tc-99m MIBI scintimammography in detecting metastatic axillary lymph node involvement were 22%, 90.4%, 61.9% and 62.3%, respectively. Early L/N of malignant breast disease was significantly higher than that of benign one ($2.44{\pm}0.97\;vs\;1.94{\pm}0.78$, p=0.01). Delayed L/N had no significant difference between malignant and benign breast diseases ($1.94{\pm}0.52\;vs\;1.91{\pm}0.73$, p=0.43). Conclusion: Our study revealed that Tc-99m MIBI scintimammography was an useful diagnostic tool for the diagnosis of breast cancer. And early L/N ratio might provide complementary role in the detection of breast cancer. But the Tc-99m MIBI scintimammography had limited value in the detection of small breast cancer (less than 1 cm) and axillary lymph node metastasis.

  • PDF

Comparison of Ultrasound with $^{99m}-Tc-MIBI$ Scintimammography in the Detection of Breast Cancer (유방암의 진단에서 유방초음파 검사와 $^{99m}-Tc-MIBI$ 유방스캔의 비교)

  • Seok, Ju-Won;Kim, Seong-Jang;Kwak, Hi-Suk;Lee, Jun-Woo;Kim, In-Ju;Kim, Yong-Ki;Bae, Young-Tae;Kim, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.3
    • /
    • pp.177-184
    • /
    • 2002
  • Purpose: Ultrasonography and $^{99m}-Tc-MIBI$ scintimammography were validated as useful diagnostic tools for primary breast cancer. However, ultrasound has the problem of low specificity. We compared the diagnostic usefulness of ultrasound with $^{99m}-Tc-MIBI$ scintimammography in the diagnosis of breast cancer. Materials and Methods: This study included 174 patients who had ultrasound and $^{99m}-Tc-MIBI$ scintimammography peformed on breast masses from 1999 to 2000. The pathologic results were obtained by surgery or FNAB. Results: Among the 174 patients, malignant breast disease numbered 117 and benign breast disease numbered 57. Ultrasound revealed 88 TP, 9 FN, 8 FP, 34 TN, and 35 indeterminate cases. $^{99m}-Tc-MIBI$ scintimammography revealed 91 TP, 25 FN, 9 FP, and 48 TN. The sensitivity, specificity, positive predictive value, and negative predictive value of Ultrasound were 66.7%, 44.2%, 67.2%, and 43.6% respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of $^{99m}-Tc-MIBI$ scintimammography were 77.8%, 84.2%, 91%, and 64.9% respectively. Among the 35 indeterminate ultrasound cases, $^{99m}-Tc-MIBI$ scintimammography revealed 13 TP, 15 TN, and 7 FP Conclusion: $^{99m}-Tc-MIBI$ Scintimammography was more sensitive and specific than ultrasound for the detection of primary breast cancer and provided more useful information in cases of indeterminate ultrasound findings.

The value of Dedicated Tc-99m MIBI Scintimammography in the Evaluation of Patients with Palpable Breast Lesions in Comparison with Mammography: Preliminary Result (만져지는 유방 병소를 평가하는데 있어 Tc-99m MIBI 유방스캔과 유방촬영 술의 비교: 예비 결과)

  • Cho, Arthur;Cho, Ho-Jin;Yun, Mi-Jin;Park, Byeong-Woo;Kim, Min-Jung;Kim, Eun-Kyung;Kang, Won-Jun;Lee, Jong-Doo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.1
    • /
    • pp.48-54
    • /
    • 2009
  • Purpose: There are few studies evaluating the usefulness of dedicated high-resolution scintimammography and no studies using delayed washout with this dedicated high resolution scintimammography for the evaluation of breast lesions. We underwent this study to evaluate the clinical usefulness of Tc-99m MIBI in evaluating patients with palpable breast lesions using dedicated high-resolution scintimammography. Materials and Methods: This study included 19 patients with 23 palpable breast lesions who underwent mammography. Tc-99m MIBI was taken to further characterize these lesions. Scintimammography images were acquired with standard craniocaudal and mediolateral oblique views and delayed images were additionally taken. Final conclusions were based on histopathology, either by biopsy or mastectomy results. Results: Eighteen lesions were malignant and five were benign. Mammography was indeterminate for thirteen lesions, nine of those were malignant. Mammography also categorized one lesion as benign in a dense breast, but scintimammography and pathology results showed malignancy. Of the five benign lesions, two were visible on scintimammography, but delayed images showed washout. Conclusion: Based on our preliminary results, dedicated high resolution scintimammography seems to be very useful in characterizing palpable lesions that were indeterminate or negative on mammography.

$^{99m}Tc$-Tetrofosmin Scintimammography in Suspected Breast Cancer Patients: Comparison with $^{99m}Tc$-MIBI (유방암이 의심되는 환자에서 $^{99m}Tc$-Tetrofosmin을 이용한 유방스캔: $^{99m}Tc$-MIBI와 비교)

  • Kim, Seong-Jang;Kim, In-Ju;Kim, Yong-Ki;Bae, Young-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.2
    • /
    • pp.119-128
    • /
    • 2000
  • Purpose: The aim of this study was to investigate the diagnostic role of $^{99m}Tc$-Tetrofosmin in detection of breast cancer and compared with that of $^{99m}Tc$-MIBI. Material and Methods: Forty-eight patients with a clinically palpable mass or abnormal mammographic or ultrasonographic findings had $^{99m}Tc-MIBI\;and\;^{99m}Tc$-Tetrofosmin scintimammographies after intravenous injection of 925 MBq of radiopharmaceuticals. The scintimammographs were correlated with histopathologic findings. Results: Thirty-three patients were diagnosed with breast cancer and 15 patients with benign breast diseases. The numbers of true positive, true negative, false positive, and false negative cases of $^{99m}Tc$-MIBI scintimammography were 29, 10, 5, and 4 respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of $^{99m}Tc$-MIBI scintimammographies were 87.8%, 66.7%, 85.3%, and 71.4% respectively. The numbers of true positive, true negative, false positive, and false negative cases of $^{99m}Tc$-Tetrofosmin were 31,10, 5, and 2 respectively. The sensitivity, specificity, positive predictive value, negative predictive value of $^{99m}Tc$-Tetrofosmin were 93.9%, 66.7%, 86.1%, and 73.3% respectively. One patient was false negative in both $^{99m}Tc-MIBI\;and\;^{99m}Tc$-Tetrofosmin acintimammographies and its size was 0.5 cm. Conclusion: $^{99m}Tc-Tetrofosmin\;and\;^{99m}Tc-MIBI$ were non-invasive and useful in detection of breast cancer and $^{99m}Tc$-Tetrofosmin was comparable to the $^{99m}Tc$-MIBI in detection of primary breast cancer.

  • PDF

The Usefulness of Mammography and Scintimammography in Differential Diagnosis of Breast Tumor (유방 종괴에서 악성 감별을 위한 유방촬영술과 유방스캔의 유용성 연구)

  • Kang, Bong-Joo;Chung, Young-An;Jung, Hyun-Seok;Jung, Jung-Im;Yoo, Ie-Ryung;Kim, Sung-Hoon;Sohn, Hyung-Sun;Chung, Soo-Kyo;Hahn, Seong-Tai;Lee, Jae-Mun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.6
    • /
    • pp.492-497
    • /
    • 2004
  • Purpose: it is very important to differentiate breast cancer from benign mass. There are many reports to evaluate the differential diagnosis under the several diagnostic tools. We evaluated the usefulness of mammography and Tc-99m MIBI scintimammography in the differential diagnosis of breast mass and correlated with pathologic findings. Materials and Methods: This study included 80 patients (a8e: 24-72, mean: 48.4) who underwent mammography and Tc-99m MIBI scintimammography for breast masses. Scintimammographies (anterior-posterior and lateral projections) were acquired in 10 minutes and 2 hours after intravenous injection of Tc-99m MIBI. four specialists in diagnostic radioloay and nuclear medicine evaluated the findings of breast masses under the mammography and Tc-99m MIBI scintimammography, and calculated the tumor to background (T/B) ratio. The pathologic results were obtained and we statistically analyzed the correlations between pathologic results and imaging findings under the mammography and Tc-99m MIBI scintimammography by chi-square and correlation test. Results: The sensitivity, specificity, positive predictive value, and negative predictive value of mammography for detection of breast cancer were 87.5%, 56.3%, 75.0%), and 75.0% respectively. 45 cases of 80 patients were suspicious for breast cancer under the Tc-99m MIBI scintimammography. 41 cases of 45 patients were confirmed as breast cancer and the remaining 4 cases were confirmed as benign masses. The sensitivity, specificity, positive predictive value and negative predictive value of Tc-99m MIBI scintimammography for detection of breast cancer were 85.4%, 87.5%, 91.1%, and 80.8% respectively. The sensitivity of scintimammography was lower than that of mammography for detection of breast cancer, however the specificity, positive predictive value, and negative predictive value were higher. In the benign mass, the mean T/B ratio in 10 minutes was $1.409{\pm}0.30$, and that in 2 hours was $1.267{\pm}0.42$. The maximal T/B ratio of benign mass in 10 minutes was $1.604{\pm}0.42$, and that in 2 hours was $1.476{\pm}0.50$. In the malignant mass, the mean T/B ratio in 10 minutes was $2.220{\pm}1.07$, and that in 2 hours was $1.842{\pm}0.75$. The maximal T/B ratio of malignant mass was $2.993{\pm}1.94$, and that in 2 hours was $2.480{\pm}1.34$. And the T/B ratio under the early and delayed images were meaningful. Conclusion: The scintimammography is useful diagnostic tool to differentiate breast cancer from benign mass, although the sensitivity of mammography for detection of breast mass is high. Especially, the use of the T/B ratio is helpful to diagnose breast cancer.

The Role of Scintimammography in the Diagnosis of Breast Cancer (유방암 진단에서 유방스캔의 역할)

  • Kim, In-Ju
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.4
    • /
    • pp.213-223
    • /
    • 2001
  • Breast cancer accounts for the higher proportion of cancer related deaths among women, and the incidence of this malignant disease is still increasing. The commonly used screening method is mammography. However, mammography has the drawback of low specificity in differentiating malignant and benign breast diseases. To overcome this low specificity of mammography, scintimammography using various radiopharmaceuticals such as Thallium-201, Tc-99m MIBI, Tc-99m tetrofosmin and Tc-99m MDP was introduced and now actively under the investigation. Several studios have shown that high sensitivity and specificity in detection of primary breast cancer and axillary lymph node metastases using these radiopharmaceuticals. Scintimammography may play important roles in the diagnosis of primary breast cancer, evaluation of the patients with high risk, determining axillary lymph node metastasis, evaluation of the response to chemotherapy, determining the extent of disease, and surveillance of local recurrence. In the future, we should investigate the prognostic role of scintimammography after treatment of breast cancer patients and cost-effectiveness of scintimammography in the detection of primary breast cancer.

  • PDF

Relationship between the Expression of Sodium Iodide Symporter and the Findings of $^{99m}Tc-MIBI$ Scintimammography in the Primary Breast Cancer (원발성 유방암에서 Sodium Iodide Symporter의 발현과 $^{99m}Tc-MIBI$ 유방스캔의 관계)

  • Seok, Ju-Won;Kim, Seong-Jang;Kwak, Hi-Suk;Lee, Chang-Hun;Kim, In-Ju;Kim, Yong-Ki;Bae, Young-Tae;Kim, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.6
    • /
    • pp.325-332
    • /
    • 2002
  • Purpose: Human Na+/I- symporter (hNIS) is known to be expressed in many tissues other than thyroid gland. The breast cancer cells are one of them and the possibility of radioiodine therapy in treatment of the breast cancer may be suggested. We investigated the expression rate of hNIS and the relationship between the expression of hNIS and the finding of 99mTc-MIBI scintimammographv in the breast cancer Materials and Methods: Surgically proved 56 patients with breast cancer were the subjects of this study The expression of hNIS were evaluated by immunohistochemistry and the results were compared to the findings of 99m7c-MIBI scintimammography. Results: Overall expression rate of hNIS was 41.1% in 56 patients. According to the pathologic diagnosis, it was 42.9% in 49 patients with invasive ductal carcinoma and 28.6% in the 7 patients with ductal carcinoma in situ. The expression rate of hNIS in the 41 cases with a focal increased uptake at he breast lesion on 99m7c-MIBI sointimammogram was 31.7%. That in the 15 cases without any abnormal uptake on the scan was significantly higher(65.7%, p<0.05). Conclusion: The expression rate of hNIS in the patients with breast cancer was not so high. The rate was higher in the patients with no increased uptake at the breast lesion on 99m7c-MIBI scintimammography.

Comparison of Tc-99m-Tetrofosmin and Tc-99m-MIBI Scintimammography in Differential Diagnosis of Breast Mass (유방종양의 감별진단에서 Tc-99m-Tetrofosmin과 Tc-99m-MIBI 유방신티그라피의 비교)

  • Park, Jung-Mi;Choi, Joon-Young;Lee, Kyung-Han;Choi, Yong;Choe, Yearn-Seong;Kim, Sang-Eun;Kim, Byung-Tae;Nam, Seok-Jin;Yang, Jeong-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.5
    • /
    • pp.393-402
    • /
    • 2000
  • Purpose: Tc-99m-MIBI (MIBI) and Tc-99m-Tetrofosmin (TF) are commonly used for scintimammog (SMM). We compared the diagnostic ability of SMM using Tc-99m-MIBI and Tc-99m-TF for the diagnosis of breast mass. Materials and Methods: The study subjects were comprised of 123 breast lesior 86 normal breasts of 114 patients who underwent SMM. Bilateral prone images and anterior supine images obtained at 5 minutes and 1 or 3 hours after intravenous injection of 740 MBq of either MIBI or TF. of tumors were not significantly different between the MIBI and TF groups. First, two observers read the SMM without clinical information (1st interpretation), then read again with information about location (2nd interpretation). Sensitivity and specificity of each radiopharmaceutical for the diagnosis of cancer were evaluated in terms of image acquisition time, tumor size, and location. Results: The SMM a good agreement between two observers for 1st and 2nd interpretation, except for TF SMM at 3 hr. first interpretation, the sensitivities at 5 min, 1 hr, and 3 hr were not significantly different between MIBI TF SMM (81.6%, 80.0%, 60.9% in MIBI vs. 88.9%, 80.6%, 42.9% in TF), although the sensitivities of images were significantly lower than 5 min images in both MIBI and TF SMM. The specificity of TF at was superior to that of MIBI (81.5%, 90.0%, 82.9% in MIBI vs. 96.7%, 100%, 90.0% in TF, p<0.01 MIBI TF at 5 min). For the second interpretation with information of mass location, the sensitivities at 3 hr were significantly lower than 5 min images (86.8%, 86.7%, 78.3% in MIBI vs. 88.9%, 93.5%, 57.1% between MIBI and TF SMM. However, there was no significant difference in the specificity (60.0%, 75.0% for MIBI vs. 86.7%, 100%, 100% for TF). MIBI and TF SMM showed lower sensitivities for the with less than 1 cm than tumors with more than 1 cm. However, the location of tumors did not sensitivity and specificity between MIBI and TF SMM. Conclusion: The ability for the differential of breast tumor is similar between MIBI and TF SMM, and delayed image is not necessary. TF may be than MIBI considering the specificity of SMM without clinical information and labeling convenience.

  • PDF