• Title/Summary/Keyword: $^{99}Tc$

Search Result 1,457, Processing Time 0.044 seconds

Chemical and Bacteriological Water Qualify of the Sonakdong River (서낙동강 강수의 화학적${\cdot}$세균학적 수질)

  • KIM Yong Gwan
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.19 no.4
    • /
    • pp.347-355
    • /
    • 1986
  • The Sonakdong river is very important water source not only for agricultural water of Kimhae field but also for fishery water. Recently the middle and lower areas of the river have the tendency to be heavily contaminated by domestic sewage and agricultural chemicals. Fifty six water samples were collected from 8 stations from July to December in 1985 for the experiment (Fig. 1). To evaluate the water quality, pH, water temperature, electrical conductivity, chloride ion, nutrients ($NO^{-}_{2}-N,\;NO^{-}_{3}-N,\;NH^{+}_{4}-N,\;PO^{3-}_{4}-P,\;SiO_2-Si$), total coliform, fecal coliform, and fecal streptococcus were determined. Range and mean value of the samples were as follows; pH $6.3{\sim}9.4$, 7.91; water temperature $6.1{\sim}34.8^{\circ}C,\;23.88^{\circ}C$; electrical conductivity (from St. A to G) $1.575{\times}10^2{\sim}30.50{\times}10^2{\mu}{\mho}/cm,\;6.57{\times}10^2{\mu}{\mho}/cm$; chloride ion $23.5{\sim}14,300mg/l$, 770.0mg/l; nitrite-nitrogen $0.007{\sim}0.110mg/l$, 0.053mg/l; nitrate-nitrogen $0.001{\sim}1.638mg/l$, 0.649 mg/l; ammonia-nitrogen $0.017{\sim}4.200mg/l$, 0.497mg/l; phosphate-phoshorus $0.011{\sim}0.281mg/l$, 0.086mg/l; and silicate-silicious $2.4{\sim}6.5mg/l$, 4.43mg/l. Electrical conductivity and chloride ion of the station F(Chomanpo) were $2.676{\times}10^2{\mu}{\Omega}cm$ and 123.99mg/l which were lower than those of others. Among the analyzed nutrients, silicate-silicious concentration was the highest through all the samples. The bacterial density of the samples ranged $36{\sim}110,000/100ml$ for total coliform, $15{\sim}46,000/100ml$ for fecal coliform and $3.6{\sim}15,000/100ml$ for fecal streptococcus. The range and the mean of the TC/FC ratio were $3.0{\sim}9.6$, 5.51 and those of the FC/FS ratio were $1.1{\sim}9.2$, 6.19, respectively. On the other hand, fecal coliform was not detected in about $78\%$ of the water samples examined. Composition of coliform was $52\%$ Escherichia coli group, $3\%$ Citrobacter freundii group, $13\%$ Enterobacter aerogenes group and $31\%$ others.

  • PDF

Avascular Necrosis of Femoral Head on Bone Scan (대퇴골두 무혈성 괴사의 뼈스캔상의 병기)

  • Yang, Hyung-In;Kim, Eui-Jong;Kim, Deog-Yoon;Ryu, Kyung-Nam;Cho, Kyung-Sam
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.206-213
    • /
    • 1994
  • We studied 90 patients(179 femoral heads) with avascular necrosis of femoral head, who had been performed X-ray, bone scan and MRI to compare of the findings of AVN on bone scan between each other, retrospectively. The patients were 82 males and 9 females, their mean age was 45 years. Radiographic stages were classified by Steinberg modification, radionuclide stages were classified as followed; stage o(or type 0) : normal, stage 1 : faint ring like uptake around the femoral head, stage 2: intense ring like uptake, stage 3: irregular increased uptake with central photon defect, stage 4 : Intense diffuse increased uptake at femoral head and stage 5 : hip joint deformity with relatively mild increased uptake. The findings of MRI were classified according to extent, location, early or advanced lesion, signal intensity of the lesion and joint effusion. 156(87%) of 179 femoral heads had avascular necrosis, 68(75.5%) of 90 patients had bilateral AVN, 35 femoral heads had early stage and 120 had advanced stage. The detection rate of AVN by X-ray and bone scan were 85% (134), 91.6% (143), respectively. Early AVN with atypical types of bone scan showed larger extent, moderate to large amount of joint effusion, soft tissue hypertrophy within joint, and secondary degenerative changes. Bone scan had relatively high detection rate in the diagnosis of AVN of femoral head, and demonstrated various types depending on the disease stage.

  • PDF

The Role of Hepatobiliary Scintiuaphy and Oral Cholecystography in Predicting the Performance of Laparoscopic Cholecystectomy (복강경담낭절제술에서 수술전 간담도신티그라피와 경구담낭조영술의 의의)

  • Won, Kyoung-Sook;Moon, Dae-Hyuk;Yang, Seoung-Oh;Han, Dong-Bok;Park, Cheol-Min;Lee, Moon-Gyu;Lee, Hee-Kyung;Park, Kwang-Min;Lee, Sung-Gyu;Ryu, Jin-Sook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.102-107
    • /
    • 1997
  • Laparoscopic cholecystectorny can be performed safely in most patients with symptomatic cholelithiasis. Preoperative evaluation should assess the potential problems that affect the performance of laparoscopic cholecystectomy. Hepatobiliary scintigraphy or oral cholecystography can assess the gallbladder function and nonvisualization of gallbladder usually indicates acute or severe chronic cholecystitis. The purpose of this study was to evaluate the role of preoperative hepatobiliary scintigraphy or oral cholecystography in predicting the performance of laparoscopic cholecystectorny. The study group consists of 176 patients who underwent both hepatobiliary scintigraphy with Tc-99m DISIDA and oral cholecystography within one month before laparoscopic cholecystectomy. Nonvisualization of gallbladder was defined as persistent nonvisualization of gallbladder until 4 hours on hepatobiliary scintigraphy or 12 hours on oral cholecystography. Among 176 patients, gallbladder was not visualized in 38 patients on hepatobiliary scintigraphy and 41 patients on oral cholecystography. Concordance rate between hepatobiliary scintigraphy and oral cholecystography was 89.2%. The conversion rate to open cholocystectomy was significantly higher in patients with nonvisualization of gallbladder than in patients with gallbladder visualization(15.8% vs 2.9% on hepatobiliary scintigraphy, 12.2% vs 3.7% on oral cholecystography p<0.01 and p<0.05 respectively). The operative complication rate was also significantly higher in patients with nonvisualization of gallbladder (13.2% vs 2.9% on hepatobiliary scintigraphy, 14.6% vs 2.2% on oral cholecystography p<0.01 and p<0.001, respectively). Similarly, operation time was significantly prolonged in patients with nonvisualization of gallbladder ($88.8{\pm}41.9min$ vs $62.5{\pm}23.6min$ on hepatobiliary scintigraphy : p<0.001, $89.4{\pm}41.3$ min vs $61.8{\pm}22.8$ min on oral cholecystography : p<0.001). It is concluded that nonvisualization of gallbladder on hepatobiliary scintigraphy or oral cholecystography is a valuable preoperative clinical risk factor in predicting increased conversion rate to open cholecystectomy, increased operative complication and prolonged operation time.

  • PDF

The Usefulness of LEUR Collimator for 1-Day Basal/Acetazolamide Brain Perfusion SPECT (1-Day Protocol을 사용하는 Brain Perfusion SPECT에서 LEUR 콜리메이터의 유용성)

  • Choi, Jin-Wook;Kim, Soo-Mee;Lee, Hyung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.94-100
    • /
    • 2011
  • Purpose: Basal/Acetazolamide-challenged brain perfusion SPECT is very useful to assess cerebral perfusion and vascular reserve. However, as there is a trade off between sensitivity and spatial resolution in the selection of collimator, the selection of optimal collimator is crucial. In this study, we examined three collimators to select optimal one for 1-day brain perfusion SPECT. Materials and Methods: Three collimators, low energy high resolution-parallel beam (LEHR-par), ultra resolution-fan beam (LEUR-fan) and super fine-fan beam (LESFR-fan), were tested for 1-day imaging using Triad XLT 9 (TRIONIX). The SPECT images of Hoffman 3D brain phantom filled with 99mTc of 170 MBq and a normal volunteer were acquired with a protocol of 50 kcts/frame and detector rotation of 3 degree. Filterd backprojection (FBP) reconstruction with Butterworth filter (cut off frequencies, 0.3 to 0.5) was performed. The quantitative and qualitative assessments for three collimators were performed. Results: The blind tests showed that LESFR-fan provided the best image quality for Hoffman brain phantom and the volunteer. However, images for all the collimator were evaluated as 'acceptable'. On the other hand, in order to meet the equivalent signal-to-noise ratio (SNR), total acquisition time or radioactivity dose for LESFR-fan must have been increased up to almost twice of that for LEUR-fan and LEHR-par. The volunteer test indicated that total acquisition time could be reduced approximately by 10 to 14 min in clinical practice using LEUR-fan and LEHR-par without significant loss on image quality, in comparison with LESFR-fan. Conclusion: Although LESFR-fan provides the best image quality, it requires significantly more acquisition time than LEUR-fan and LEHR-par to provide reasonable SNR. Since there is no significant clinical difference between three collimators, LEUR-fan and LEHR-par can be recommended as optimal collimators for 1-day brain perfusion imaging with respect to image quality and SNR.

  • PDF

Applications of "High Definition Digital Climate Maps" in Restructuring of Korean Agriculture (한국농업의 구조조정과 전자기후도의 역할)

  • Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.9 no.1
    • /
    • pp.1-16
    • /
    • 2007
  • The use of information on natural resources is indispensable to most agricultural activities to avoid disasters, to improve input efficiency, and to increase lam income. Most information is prepared and managed at a spatial scale called the "Hydrologic Unit" (HU), which means watershed or small river basin, because virtually every environmental problem can be handled best within a single HU. South Korea consists of 840 such watersheds and, while other watershed-specific information is routinely managed by government organizations, there are none responsible for agricultural weather and climate. A joint research team of Kyung Hee University and the Agriculture, forestry and Fisheries Information Service has begun a 4-year project funded by the Ministry of Agriculture and forestry to establish a watershed-specific agricultural weather information service based on "high definition" digital climate maps (HD-DCMs) utilizing the state of the art geospatial climatological technology. For example, a daily minimum temperature model simulating the thermodynamic nature of cold air with the aid of raster GIS and microwave temperature profiling will quantify effects of cold air drainage on local temperature. By using these techniques and 30-year (1971-2000) synoptic observations, gridded climate data including temperature, solar irradiance, and precipitation will be prepared for each watershed at a 30m spacing. Together with the climatological normals, there will be 3-hourly near-real time meterological mapping using the Korea Meteorological Administration's digital forecasting products which are prepared at a 5 km by 5 km resolution. Resulting HD-DCM database and operational technology will be transferred to local governments, and they will be responsible for routine operations and applications in their region. This paper describes the project in detail and demonstrates some of the interim results.

Impact and Prevalence of Renin-angiotensin System Gene Polymorphism of Renal Anomalies in Turner Syndrome (터너 증후군에서 신기형의 발생에 미치는 레닌-안지오텐신계 유전자 다형성의 영향)

  • Park Ji-Kyoung;Chung Young-Hee;Lee Jeong-Nyeo;Chung Woo-Yeong
    • Childhood Kidney Diseases
    • /
    • v.7 no.1
    • /
    • pp.52-59
    • /
    • 2003
  • Purpose : The renin-angiotensin system(RAS) plays an important role in renal growth and development. We have studied the prevalence of renal anomalies and documented the association between karyotype and renal anomalies using IVP and ultrasonography. Furthermore, to investigate the impact of RAS gene polymorphism on renal anomaly in Turner syndrome, we examined the ACE I/D genotype, angiotensinogen(AGT) gene M235T, angiotensin receptor type 1(ATR) gene A1166C. Methods : Cytogenetic analysis was performed in 33 Turner syndrome patients on peripheral blood lymphocytes. Ultrasonography(US) of the kidneys and collecting system and intravenous pyelography(IVP) were perfomed in all patients. Nuclear scintigraphy{Tc 99m dimercaptosuccinic acid(DMSA) scan} was also performed for the definite renal diagnosis if indicated. And, ACE I/D genotype, angiotensinogen(AGT) gene M235T, angiotensin receptor type 1(ATR) gene A1166C were examined by PCR amplification of genomic DNA samples. Results : The prevalence of renal anolmalies in Turner syndrome was 36.4%(12/33). The Karyotype 45, X was observed in 18 of the 33 girls(54.5%), of whom 8(44.4%) had renal anomalies. Mosaic karyotypes were observed in 11(33.3%) and four(12.2%) had a non-mosaic structural aberration of the X chromosome. In this group 4(25.7%) had renal anomalies. More renal anomalies were associated with the 45, X karyotype than those with mosaic/structural abnormalities of X chromosome, but the difference was not statistically significant(P>0.05). And, there was no significant differences in the RAS gene polymorphism and allele frequencies between renal anomaly group and normal group in Turner syndrome. Conclusion : The prevalence of renal anolmalies in Turner syndrome was 36.4%. There is no significant differences in the RAS gene polymorphism and allele frequencies between the renal anomaly group and the normal group in Turner syndrome.

  • PDF

Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging (NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, Jong-Ho;Choi, Yong;Kwon, Hong-Seong;Kim, Hee-Joung;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Moon-Hae;Joo, Koan-Sik;Kim, Byuug-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 1998
  • Purpose: The conventional gamma camera is not ideal for scintimammography because of its large detector size (${\sim}500mm$ in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. Materials and Methods: The small gamma camera system consists of a NaI (T1) crystal ($60 mm{\times}60 mm{\times}6 mm$) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals ($X^+,\;X^-,\;Y^+,\;Y^-$). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated ana digitized via triggering signal and used to localize the position of an event by applying the Anger logic. Results: The intrinsic sensitivity of the system was approximately 8,000 counts/sec/${\mu}Ci$. High quality flood and hole mask images were obtained. Breast phantom containing $2{\sim}7 mm$ diameter spheres was successfully imaged with a parallel hole collimator The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We have succesfully developed a small gamma camera using NaI(T1)-PSPMT and nuclear Instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammography by optimally imaging the breast.

  • PDF

Detection of Spinal Metastases: Comparison of Bone Scan and MR Imaging (전이성 척추 악성 종양의 진단 : 골스캔과 자기공명영상의 비교)

  • Kim, Ki-Jun;Sohn, Hyung-Sun;Park, Jeong-Mi;Chung, Soo-Kyo;Lee, Jae-Moon;Kim, Choon-Yul;Bahk, Yong-Whee;Shinn, Kyung-Sub
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.384-390
    • /
    • 1994
  • Authors retrospectively compared the 99mTc MDP bone scans and corresponding MR imagings in 20 patients with histologically proven malignancy, Mean interval of the two studies was 16.6 days, Cancer diagnosis Included 8 lung, 2 each of colon, breast, stomach, 1 each of prostate, thyroid, malignant lymphoma and 3 adenocarcinoma of unknown primary site. Of the 105 regions compared, :t6 regions were positive for metastases in bone scans or MR imagings. 30 regions(65.2%) were positive by bone scan and 44 regions(95.7%) by MR imaging. 87 regions(82.9%) were concordantly positive or negative by bone scan and MR imaging, but 18 regions(17.1%) were discordant. In the discordant regions, 16 regions positive in MR imaging were negative in bone scan. The greatest number of discordant findings occured in the cervical region and in the patient with stomach cancer. Our results suggest that the sensitivity of MR Imaging is greater than that of bone scan in detecting spinal metastases. And bone scan is useful screening test of metastasis for evaluating entire skeleton including spine.

  • PDF

Optimization of Subtraction Brain Perfusion SPECT with Basal/Acetazolamide Consecutive Acquisition (기저/아세타졸아미드 부하 연속 촬영 뇌관류 SPECT 최적화)

  • Lee, Dong-Soo;Lee, Tae-Hoon;Kim, Kyeong-Min;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.330-338
    • /
    • 1997
  • This study investigated the method to adjust acquisition time(a) and injection dose (i) to make the best basal and subtraction images in consecutive SPECT. Image quality was assumed to be mainly affected by signal to noise ratio(S/N). Basal image was subtracted from the second image consecutively acquired at the same position. We calculated S/N ratio in basal SPECT images($S_1/N_1$) and subtraction SPECT images(Ss/Ns) to find a(time) and i(dose) to maximize S/N of both images at the same time. From phantom images, we drew the relation of image counts and a(time) and i(dose) in our system using fanbeam-high-resolution collimated triple head SPECT. Noise by imaging process depended on Poisson distribution. We took maximum tolerable duration of consecutive acquisition as 30 minutes and maximum injectible dose as 1,850MBq(50 mCi)(sum of two injections) per study. Counts of second-acquired image($S_2$), counts($S_s$) and noise($N_s$) of subtraction SPECT were as follows. $C_1$ was the coefficient of measurement with our system. $$S_2=S_1{\cdot}(\frac{30-a}{a})+background{\cdot}(1-\frac{30-a}{a})+C_1{\cdot}(30-a){\cdot}{\epsilon}{\cdot}(50-i)$$ $$Ss=S_2-\{S_1{\cdot}(\frac{30-a}{a})+background{\cdot}(1-\frac{(30-a)}{a})\}$$ $$Ns={\sqrt{N_2^2+N_1^2{\cdot}\frac{(30-a)^2}{a^2}}={\sqrt{S_2+S_1{\cdot}\frac{(30-a)^2}{a^2}}$$ In case of rest/acetazolamide study, effect(${\epsilon}$) of acetazolamide to increase global brain uptake of Tc-99m-HMPAO could be 1.5 or less. Varying ${\epsilon}$ from 1 to 1.5, a(time) and i(dose) pair to maximize both $S_1/N_l$ and Ss/Ns was determined. 15 mCi/17 min and 35mCi/13min was the best a(time) and i(dose) pair for rest/acetazolamide study(when ${\epsilon}$ were 1.2) and came to be used for our clinical routine after this study. We developed simple method to maximize S/N ratios of basal and subtraction SPECT from consecutive acquisition. This method could be applied to ECD/HMPAO and brain activation studies as well as rest/acetazolamide studies.

  • PDF

Dipyridamole Induced Transient Left Ventricular Dysfunction in the Tl-201 Gated Myocardial SPECT (Tl-201 게이트 심근 SPECT에서 디피리다몰 부하로 유도된 일시적 좌심실 기능이상)

  • Won, Kyoung-Sook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.3
    • /
    • pp.153-161
    • /
    • 2003
  • Purpose: Recently the occurrence of dipyridamole stress-induced short term stunning was proven and it is reported that Bland Altman analysis by repeated acquisition Tl-201 gated myocardial SPECT (gSPECT) revealed the 95% limit of agreement for LVEF was 10.3 %. The purpose of this study was to investigate the clinical value of dipyridamole induced transient LV dysfunction on Tl-201 gSPECT. Materials and Methods: Total 93 patients were included and coronary angiography was peformed in all patients less than 2 month from gSPECT. The patients with myocardial infarction were excluded. All patients underwent both dipyridamole stress and 4-h redistribution Tl-201 gSPECT. Forty nine patients of total 93 showed normal coronary arteries (Group 1) and the remaining 44 patients had coronary artery disease (Group 2). We compared LV EF, EDV and ESV during post-stress and 4-h redistribution period calculated by gSPECT using quantitative gated SPECT software and the incidence of dipyridamole induced transient LV dysfunction between group 1 and 2. The criteria for transient LV dysfunction was defined more decrease ${\geq}11%$ of LVEF during post-stress than 4-h redistribution according to previous reported Bland Altman analysis. Results: During post-stress and 4-h redistribution average of 3.1% increment in LVEF, 6.6% increment in LVEDV and 0.7% decrement in LVESV were shown after stress in Group 1, whereas 4.1% decrement, 9.7% increment and 7.2% increment in Group 2 respectively. Dipyridamole induced transient LV dysfunction was only detected in group 2 (18.2%) and not in group 1. It was more frequently observed in triple vessel disease and left main disease (31.8%, N=22) than one and two vessel disease (4.5%, N=22). Conclusion: As with Tc-99m myocardial agent post-stress LV dysfunction was observed in dipyridamole Tl-201 gSPECT. It was only detected in CAD and more frequently occurred in multivessel disease. Thus this finding seems to provide additional information in the diagnosis of coronary artery disease and prediction of prognosis.