• Title/Summary/Keyword: $^{60}Co\{\gamma}-ray$

Search Result 273, Processing Time 0.03 seconds

Development of One-channel Gamma ray spectroscope for Automatic Radiopharmaceutical Synthesis System (방사성 의약품 자동합성장치용 단채널 감마선 분광기 보드의 설계 및 제작)

  • Song, Kwanhoon;Kim, Kwangsoo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.4
    • /
    • pp.193-200
    • /
    • 2014
  • In this paper, the prototype of one-channel gamma-ray spectroscope for automatic radiopharmaceutical systhesis system was designed and characterized. The prototype employed CZT (CdZnTe) spear detector for gamma-ray detection and employed analog-type signal processing method. A radioactive sample Co-60 was used for measuring performance of the gamma-ray spectroscope and energy spectrum is gained with bandwidth of 1173keV. The analog board is made up of SF (shaping filter) and PHA (peak and hold amplifier) for shaping CZT output signal appropriately and ADC (analog to digital converter) and FPGA (field programmable gate array) for drawing gamma-ray spectrum by counting the digitalized gamma-ray signal data.

Comparative Measurement of Radioactivity with Standard Gamma-ray Ionization Chamber System (표준 감마선 전리함 장치에 의한 방사능 비교 측정)

  • Park, Tae-Soon;Woo, Dong-Ho;Oh, Pil-Jae;Hwang, Sun-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.1
    • /
    • pp.11-18
    • /
    • 1984
  • A Standard gamma-ray ionization chamber system was developed with a well type ionization chamber and micro current measuring circuit. Micro current was measured by the automatic Townsend balance with stepwise compensation method. For gamma emitting nuclides such as $^{241}Am,\;^{133}Ba,\;^{60}Co,\;^{134}Cs,\;^{137}Cs,\;and\;^{22}Na$ relative calibration factors to $^{226}Ra$ reference source were calculated and detection .efficiency curve was determined as a fudnction of gamma energy.

  • PDF

Application of Commercial PIN Photodiodes to develope Gamma-Ray Dosimeters (감마선 선량계를 개발하기 위한 상용 PIN 포토 다이오드의 응용)

  • Jeong, Dong-Hwa;Kim, Sung-Duck
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.274-280
    • /
    • 2000
  • This paper deals with an experimental study to apply commercial semiconductors to measure radiation dose rate for gamma ray. Since the low cost, small size, high efficiency and ruggedness of silicon photodiodes make them attractive photodetectors, they coulde be effectively used in measuring any radiation such as gamma ray. Most PN photodiodes show that the reverse current increases when the light is increased. Therefore the depletion region of them have influence on the reverse current, so we choose silicon PIN photodiodes with large depletion region. In order to detect radiation dose rate and then, to apply in developing any gamma ray dosimeter, some examinations and experiments were performed to PIN photodiodes in this work. Two kinds of PIN photodiodes, such as NEC's PH302 and SIEMENS's BPW34, were tested in a Co-60 gamma irradiation facility with a semiconductor parameter analyzer. As a result, we found that such PIN photodiodes present good linearity in diode current characteristics with dose rate. Therefore silicon PIN photodiodes could be suitably used in designing gamma ray dosimeters.

  • PDF

A Study on the X-ray Image Reading of Radiological Dispersal Device (방사능 폭발물의 X-ray 영상판독에 관한 연구)

  • Geun-Woo Jeong;Kyong-Jin Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.2_2
    • /
    • pp.437-443
    • /
    • 2024
  • The purpose of radiological Dispersal Device(RDD) is to kill people by explosives and to cause radiation exposure by dispersing radioactive materials. And It is a form of explosive that combines radioactive materials such as Co-60 and Ir-192 with improvised explosives. In this study, we tested and evaluated whether it was possible to read the internal structure of an explosive using X-rays in a radioactive explosive situation. The improvised explosive device was manufactured using 2 lb of model TNT explosives, one practice detonator, one 9V battery, and a timer switch in a leather briefcase measuring 41×35×10 cm3. The radioactive material used was the Co-60 source used in the low-level gamma ray irradiation device operated at the Advanced Radiation Research Institute of the Korea Atomic Energy Research Institute. The radiation dose used was gamma ray energy of 1.17 MeV and 1.33 MeV from a Co-60 source of 2208 Ci. The dose rates are divided into 0.5, 1, 2, and 4 Gy/h, and the exposure time was divided into 1, 3, 5, and 10 minutes. Co-60 source was mixed with the manufactured explosive and X-ray image reading was performed. As a result of the experiment, the X-ray image appeared black in all conditions divided by dose rate and time, and it was impossible to confirm the internal structure of the explosive. This is because γ-rays emitted from radioactive explosives have higher energy and stronger penetrating power than X-rays, so it is believed that imaging using X-rays is limited By blackening the film. The results of this study are expected to be used as basic data for research and development of X-ray imaging that can read the internal structure of explosives in radioactive explosive situations.

In-Service Identification of the Heterogeneous Zone in Petrochemical Pipelines by Using Sealed Gamma-Ray Sources $(^{60}Co,\;^{137}Cs)$

  • Kim, Jin-Seop;Jung, Sung-Hee;Kim, Jong-Bum
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.3
    • /
    • pp.169-173
    • /
    • 2006
  • In-service diagnoses of pipeline facilities are important for a systematic maintenance of them. Field applications by using sealed gamma-ray sources $(^{60}Co,\;^{137}Cs)$ were performed to identify the heterogeneous zone in the pipelines of a distillation tower and a flare stack respectively. From the results, the heterogeneous zones in the pipelines were successfully identified. In the case of the pipeline connected to the distillation tower, a vapor pocket was detected in the fluid under hydrodynamic conditions, which could explain the reason for a decrease of the flow rate. In another case, an area with some amount of catalyst deposits was found at the bottom of the gas pipeline which was connected to the flare stack. And these findings provided important information for the process operators. Diagnosis technique by using gamma radiation sources has been proven to be an effective and reliable method for providing information on a media distribution in a facility.

Measurements of the Direction and Polarization Correlation for Cascade Gamma-rays of Co-60 and Cs-134 (Co-60과 Cs-134의 연발감마선에 대한 방향 및 편극상관 측정)

  • Hyung-Ju Woo;Kie-Hyung Chung;Hae-Ill Bak
    • Nuclear Engineering and Technology
    • /
    • v.14 no.2
    • /
    • pp.64-69
    • /
    • 1982
  • Directional correlation measurements for the Co-60 and Cs-134 cascade gamma-rays have been performed in the angular range from 90$^{\circ}$ to 180$^{\circ}$ by use of the fast coincidence scintillation spectrometer incorporated with a gamma-ray polarimeter based on the Compton scattering effect to determine the polarization correlations. The experimental method together with the theoretical background is described, and the results are shown graphically to represent the consistency of the measurement with approximate theoretical estimates.

  • PDF

A Study on Dobe Distribution outside Co-60 $\gamma$ Ray ana 10MV X Ray Fields ($^{60}Co\;\gamma$선과 10MV X선의 조사면 밖의 선량분포에 관한 연구)

  • Kang, Wee-Saing;Huh, Seung-Jae;Ha, Sung-Whan
    • Radiation Oncology Journal
    • /
    • v.2 no.2
    • /
    • pp.271-280
    • /
    • 1984
  • The peripheral dose, defined as the dose outside therapeutic photon fields, which is responsible for the functional damage of the critical organs, fetus, and radiation. induced carcinogenesis, has been investigated for $^{60}Co\;\gamma$ ray and 10 MV Xray. It was measured by silicon diode controlled by semiautomated water phantom without any shielding or with lead plate of HVL thickness put horizontally or vertically to shield stray radiations. Authors could obtain following results. 1. The peripheral dose was larger than $0.7\%$ of central axis maximum dose even at 20cm distance from field margin. That is clinically significant, so it should be reduced. 2. Even for square fields of 10 MV Xray, radial peripheral dose distribution did not coincide with transverse distribution, because of the position of collimator jaws. 3. Between surface and $d_m$, the peripheral dose distributions show a pattern of the dose distribution of electron beams and the maximum doss was approximately proportional to the length of a side of square field. 4. The peripheral doses depended on radiation quality, field size, distance from field margin and depth in water. Distance from field margin was the most important factor. 5. Except for near surface, the peripheral dose from phantom was approximately equal to that from therapy unit. 6. To reduce the surface dose outside fields, therapist should shield stray radiations from therapy unit by lead plate of at least one HVL for 10 MV X-ray and by bolus equivalent to tissue of 0.5cm thickness for $^{60}Co$. 7. To reduce the dose at depth deeper than $d_m$, it is desirable to shield stray radiations from therapy unit by lead.

  • PDF

Plastic scintillator beta ray scanner for in-situ discrimination of beta ray and gamma ray radioactivity in soil

  • Bae, Jun Woo;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1259-1265
    • /
    • 2020
  • A beta ray scanner was proposed for in-situ discrimination of beta and gamma ray radioactivity. This scanner is based on the principle that gamma and beta rays experience different changes in detection efficiency in scintillators with different geometries, especially with regard to the scintillator thickness. The ratios of the counting rates of gamma rays (Rgamma), beta rays (Rbeta), and sample measurements (Rtotal) in a thick scintillator to those in a thin one are reported. The parameter Xthick, which represents the counting rate contributed by beta rays to the total counting rate in the thick scintillator, was derived as a function of those ratios. The values of Rgamma and Rbeta for 60Co and 90Sr sources were estimated as 3.2 ± 0.057 and 0.99 ± 0.0049, respectively. The estimated beta ray contributions had relative standard deviations of 2.05-4.96%. The estimated range of the beta rays emitted from 90Sr was 19 mm as per the Monte Carlo N-Particle simulation, and this value was experimentally verified. Homogeneous and surface contaminations of 60Co and 90Sr-90Y were simulated for application of the proposed method. The counting rate contributed by the beta rays was derived and found to be proportional to the concentration of 90Sr-90Y contamination.

Development of Radiation Sensor Based on Array SiPM for Measurement of Radioactive Contamination in Effluent (방류수의 방사능 오염 측정을 위한 배열형 SiPM 기반 방사선 검출 센서 제작)

  • Kim, Jeongho;Park, Hyemin;Joo, Koansik
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.232-236
    • /
    • 2018
  • A radiation detection sensor was developed and characterized by combining three types of CsI(Tl) scintillators and an array-type SiPM to detect the radioactive contamination of discharged water in real time. The characterization results showed that type 3 exhibited the most desirable characteristics in response linearity (R-square: 0.97889) according to detection sensitivity and incident radiation dose. Furthermore, in terms of spectral characteristics, type 3 exhibited 16.54% at 0.356 MeV (the emission gamma ray energy of $^{133}Ba$), 10.28% at 0.511 MeV (the emission gamma ray energy of $^{22}Na$), 9.68% at 0.356 MeV (the emission gamma ray energy of $^{137}Cs$), and 2.55% and 4.80% at 1.173 MeV and 1.332 MeV (the emission gamma ray energies of $^{60}Co$), respectively. These measurements confirmed the good energy characteristics. The results were used to evaluate the spectral characteristics and energy linearity in a mixed source using type 3 with the best detection characteristics. It was confirmed that the gamma ray peaks of $^{133}Ba$, $^{22}Na$, $^{137}Cs$, and $^{60}Co$ were well resolved. Moreover, it was confirmed that R-square, which is an indicator of energy linearity, was 0.99986. This indicates a good linearity characteristic. Based on this study, further commercialization studies will contribute to measurements in real time and to the management of the contamination caused by radioactive wastewater or radioactive material leakage, which originate from facilities that use radioactive isotopes or care facilities.

The variation of chracteristics induced by $Co^60$-$\gamma$ray at the interface and oxide layer of MOS sructure ($Co^60$-$\gamma$선 조사에 따른 MOS구조의 계면 및 산화막내에서의 특성변화)

  • 김봉흡;류부형;이상돈
    • Electrical & Electronic Materials
    • /
    • v.1 no.3
    • /
    • pp.269-277
    • /
    • 1988
  • P형 Si(100)로 제작한 MOS 커패시터에 $Co^{60}$-.gamma.선을 주사한 후 고주파 C-V특성 곡선으로 부터 방사선 조사에 의해 유발된 산화막안의 트랩전하의 거동 및 Si- $SiO_{2}$계면에서의 트랩밀도 분포의 변화를 검토하였다. 산화막 느랩전하는 .gamma.선 흡수선량 증가와 더불어 증가하다가 $10^{7}$ rad 부근에서부터 서서히 포화하는 경향이 나타났으며 게면트랩밀도의 분포모양은 흡수선량의 증가와 더불어 전형적인 이그러진 W자형에서 넓혀진 V자형 분포로 변화하였으나 최소값은 항상 진성페르미준위( $E_{i}$)부근에 있었으며 그 밀도는 1.0*$10^{11}$~7.5*$10^{11}$[개/$cm^{2}$/eV]로 계산되었다. 또한, 일정 바이어스전압하에서의 조사선량에 따른 $V_{fb}$ 의 변화는 현저하지는 않았으나 바이어스 전압을 +12V로 인가할 때 변화방향의 반전상태가 관측되었다. 그 이유로는 Si측의 계면 부근에서 일어난 눈사태 전자가 산화막내로 주입됨에 따라 도너형 양전하의 수가 감소되기 때문으로 추정되었다.되었다.

  • PDF