PET/MRI에 있어 MRI 조영제가 PET에 미치는 영향 (Effect of MRI Media Contrast on PET/MRI)

  • 김재일;김인수;이홍재;김진의
    • 핵의학기술
    • /
    • 제18권1호
    • /
    • pp.19-25
    • /
    • 2014
  • PET/MRI에서는 MRI의 진단적 가치를 높이기 위해 T1 조영제를 사용하고 있다. PET의 감쇠 보정을 위해 T1 시컨스 계열인 VIBE DIXON은 조영제에 직접적으로 영향을 미치지만, 실제 ${\mu}-map$과 감쇠 보정된 PET 영상에는 큰 변화가 없었다. 그러므로 PET/MRI 검사시 조영제 사용은 PET 데이터 얻기 전 후 언제든 사용할 수 있을 것이다.

  • PDF

Prognostic value of nodal SUVmax of 18F-FDG PET/CT in nasopharyngeal carcinoma treated with intensity-modulated radiotherapy

  • Lee, So Jung;Kay, Chul-Seoung;Kim, Yeon-Sil;Son, Seok Hyun;Kim, Myungsoo;Lee, Sea-Won;Kang, Hye Jin
    • Radiation Oncology Journal
    • /
    • 제35권4호
    • /
    • pp.306-316
    • /
    • 2017
  • Purpose: To investigate the predictive role of maximum standardized uptake value ($SUV_{max}$) of 2-[$^{18}F$]fluoro-2-deoxy-D-glucose($^{18}F-FDG$) positron emission tomography/computed tomography (PET/CT) in nasopharyngeal cancer patients treated with intensity-modulated radiotherapy (IMRT). Materials and Methods: Between October 2006 and April 2016, 53 patients were treated with IMRT in two institutions and their PET/CT at the time of diagnosis was reviewed. The $SUV_{max}$ of their nasopharyngeal lesions and metastatic lymph nodes (LN) was recorded. IMRT was delivered using helical tomotherapy. All patients except for one were treated with concurrent chemoradiation therapy (CCRT). Correlations between $SUV_{max}$ and patients' survival and recurrence were analyzed. Results: At a median follow-up time of 31.5 months (range, 3.4 to 98.7 months), the 3-year overall survival (OS) and disease-free survival (DFS) rates were 83.2% and 77.5%, respectively. In univariate analysis, patients with a higher nodal pre-treatment $SUV_{max}$ (${\geq}13.4$) demonstrated significantly lower 3-year OS (93.1% vs. 55.5%; p = 0.003), DFS (92.7% vs. 38.5%; p < 0.001), locoregional recurrence-free survival (100% vs. 50.5%; p < 0.001), and distant metastasis-free survival (100% vs. 69.2%; p = 0.004), respectively. In multivariate analysis, high pre-treatment nodal $SUV_{max}$ (${\geq}13.4$) was a negative prognostic factor for OS (hazard ratio [HR], 7.799; 95% confidence interval [CI], 1.506-40.397; p = 0.014) and DFS (HR, 9.392; 95% CI, 1.989-44.339; p = 0.005). Conclusions: High pre-treatment nodal $SUV_{max}$ was an independent prognosticator of survival and disease progression in nasopharyngeal carcinoma patients treated with IMRT in our cohort. Therefore, nodal $SUV_{max}$ may provide important information for identifying patients who require more aggressive treatment.

PET/CT 2D와 3D 영상 획득에서 방사능 집적에 따른 방사능 농도의 평가 (Evaluation of Radioactivity Concentration According to Radioactivity Uptake on Image Acquisition of PET/CT 2D and 3D)

  • 박선명;홍건철;이혁;김기;최춘기;석재동
    • 핵의학기술
    • /
    • 제14권1호
    • /
    • pp.111-114
    • /
    • 2010
  • 양전자 방출 단층촬영은 세포의 생화학적 변화에 따른 방사성의약품의 집적 정도를 영상화함으로서 암을 조기에 진단할 수 있는 검사방법으로 알려져 있다. 이러한 집적 정도는 여러 가지 원인에 따라 발생될 수 있는 것으로 $^{18}F$-FDG 주사량, 종양의 크기, 혈중 포도당 농도 등이 있다. 본 연구에서는 집적방사능과 2D와 3D 영상 획득이 방사능 농도(kBq/mL)에 미치는 영향에 대하여 평가하고자 한다. GE Discovery STe 16 PET/CT에서 1994 NEMA PET phantom을 이용하였으며, 배후방사능과 열소의 방사능 농도비가 1:2, 1:4, 1:8, 1:10, 1:20, 1:30 표준이 되도록 하여 2D와 3D로 영상을 획득하였다. 재구성 방법으로 2D와 3D 모두에서 반복연산법으로 반복횟수 2회, 부분집합 20을 적용하였다. 그리고 CT 감쇠보정법과 획득 시간은 10분으로 설정하였다. 또한 영상분석은 열소의 중심과 배후방사능에 동일한 관심영역을 설정 한 후 각 부분의 방사능 농도를 측정하여 비교 분석하였다. 설정된 관심영역의 배후방사능과 열소의 방사능 농도 비는 2D에서 1:1.93, 1:3.86, 1:7.79, 1:8.04, 1:18.72, 1:26.90, 3D는 1:1.95, 1:3.71, 1:7.10, 1:7.49, 1:15.10, 1:23.24 값을 얻었다. 또한 표준 방사능 농도비를 기준으로 한 백분율 차이(% Difference)는 2D에서 3.50%, 3.47%, 8.12%, 8.02%, 10.58%, 11.06%로 최소 3.47%에서 최대 11.06% 차이가 있고 3D는 3.66%, 4.80%, 8.38%, 23.92%, 23.86%, 22.69%로 최소 3.66%에서 최대 23.92%까지의 차이를 나타냈다. 방사능 농도가 증가할수록 실제 집적된 방사능 농도의 차이가 커짐을 알 수 있으며, 2D가 3D보다 평균 약 10.6% 높게 집적되어 방사능 농도 변화에 영향을 적게 받는 것으로 나타났다. 따라서 임상환자의 추적 검사에서 영상 획득 방법을 변화할 시 정확한 정량 평가를 위해서 이점을 고려하여 적용하여야 한다.

  • PDF

PET/CT 검사 시 움직임 보정 기법의 유용성 평가 (The Correction Effect of Motion Artifacts in PET/CT Image using System)

  • 조영학;유세종;배석환;선종률;김성호;이원정
    • 한국방사선학회논문지
    • /
    • 제18권1호
    • /
    • pp.45-52
    • /
    • 2024
  • 본 연구에서는 의료기관에서 방사성동위원소를 이용하여 암을 비롯한 여러 질환을 검사하는 PET/CT 검사에서 환자의 움직임으로 인한 영상의 질 저하와 판독 오류를 발생할 수 있는 점을 보완하기 위해 AI 기반의 Algorithm을 이용하여 개발한 Mothion Free 소프트웨어를 이용하여 호흡으로 인한 움직임의 보정 정도를 확인하고 유용성을 평가하여 임상에서의 적용을 위한 연구를 하였다. 실험 방법은 RPM Phantom을 사용하여 방사성동위원소 18F-FDG를 진공 바이알과 서로 다른 크기 NEMA IEC body Phantom의 sphere에 방사성동위원소를 주입하고 이것의 움직임을 호흡 시 움직이는 병소로 연출하여 영상을 획득하였다. 진공 바이알은 서로 다른 위치에서 움직임 정도를 다르게 하였고, 서로 다른 크기 NEMA IEC body Phantom의 sphere는 서로 다른 병소의 크기를 연출 하였다. 획득한 영상을 통하여 병소의 체적, 최대 SUV, 평균 SUV를 각각 측정하여 Mothion Free가 움직임 보정 정도를 정량적 평가를 하였다. 움직임 정도를 크게 설정한 진공바이알 A의 평균 SUV는 23.36 %, 움직임 정도를 작게 설정한 진공 바이알 B는 29.3 % 오차율이 감소하였다. NEMA IEC body Phantom의 sphere 37 mm, 22 mm에서의 평균 SUV는 각각 29.3 %, 26.51 % 오차율이 감소하였다. 오차율을 산출한 네 가지 측정치의 평균 오차율 30.03 % 감소하여 보다 정확한 평균 SUV 값을 나타내었다. 이 연구에서는 2차원적인 움직임 만을 연출할 수 있었기에 보다 정확한 데이터를 얻기 위해서는 실제 인체의 호흡 운동을 구현할 수 있는 Phantom을 이용하고, 움직임의 범위의 다양성을 구성한다면 보다 정확한 유용성 평가를 할 수 있다고 연구된다.

KOTRON-13과 상용 PET 사이클로트론의 최근 기술 동향 (Recent Status of Commercial PET Cyclotron and KOTRON-13)

  • 채종서
    • 대한핵의학회지
    • /
    • 제39권1호
    • /
    • pp.1-8
    • /
    • 2005
  • 상용 PET사이클로트론의 기술적인 변화는 PET의 수요와 밀접한 관계가 있다. PET활용이 일반화 되어 미국을 중심으로 PET의 수요가 급증하게 됨에 따라 사이클로트론의 수요도 증가 하였다. 기존의 사이클로트론은 크기와 무게로 병원에 설치에 공간과 전원 공급 등 여러 문제가 있어 각 사이클로트론 제작사들은 새로운 모델을 출시하게 되었다. 새로운 모델의 특징은 다음과 같다. 첫째 기존의 모델이 양성자와 중양자 등의 2가지 이온을 인출 하였으나 시스템의 복잡성 등의 문제와 양성자로 O-15 생산이 가능하여 양성자 빔만을 인출 하거나 중양자는 선택 사양으로 전환 하였다. 둘째 기존 모델의 경우 양성자의 빔 에너지는 약 16 MeV 이상 가속 시킬 수 있으나 신 모델은 13 MeV 이내로 대폭 낮추어 PET 용 Rl생산에 최적화하였다. 셋째 전자석, RF 장치등의 최적화를 이룩하여 전력소모를 대폭 개선하였으며 외양도 대폭 작아져 무게를 20톤 이내로 대폭 낮추었다. 넷째 새로운 모델 사이클로트론들은 자체 차폐기능이 일반화 되었으나 IBA제품이나 삼영유니텍 제품은 사용자의 견지에 따라 선택 사양이 가능하다.

Prediction of response by FDG PET early during concurrent chemoradiotherapy for locally advanced non-small cell lung cancer

  • Kim, Suzy;Oh, So Won;Kim, Jin Soo;Kim, Ki Hwan;Kim, Yu Kyeong
    • Radiation Oncology Journal
    • /
    • 제32권4호
    • /
    • pp.231-237
    • /
    • 2014
  • Purpose: To evaluate the predictive value of the early response of $^{18}F$-flurodeoxyglucose positron emission tomography (FDG PET) during concurrent chemoradiotherapy (CCRT) for locally advanced non-small cell lung cancer (NSCLC). Materials and Methods: FDG PET was performed before and during CCRT for 13 NSCLC patients. Maximum standardized uptake value ($SUV_{max}$), mean standardized uptake value ($SUV_{mean}$), metabolic tumor volume (MTV), and total lesion glycolysis (TLG) were measured and the changes were calculated. These early metabolic changes were compared with the standard tumor response by computed tomograms (CT) one month after CCRT. Results: One month after the completion of CCRT, 9 patients had partial response (PR) of tumor and 4 patients had stable disease. The percent changes of $SUV_{max}$ ($%{\Delta}SUV_{max}$) were larger in responder group than in non-responder group ($55.7%{\pm}15.6%$ vs. $23.1%{\pm}19.0%$, p = 0.01). The percent changes of $SUV_{mean}$ ($%{\Delta}SUV_{mean}$) were also larger in responder group than in non-responder group ($54.4%{\pm}15.9%$ vs. $22.3%{\pm}23.0%$, p = 0.01). The percent changes of MTV ($%{\Delta}MTV$) or TLG ($%{\Delta}TLG$) had no correlation with the tumor response after treatment. All the 7 patients (100%) with $%{\Delta}SUV_{max}{\geq}50%$ had PR, but only 2 out of 6 patients (33%) with $%{\Delta}SUV_{max}$ < 50% had PR after CCRT (p = 0.009). Likewise, all the 6 patients (100%) with $%{\Delta}SUV_{mean}{\geq}50%$ had PR, but only 3 out of 7 patients (43%) with $%{\Delta}SUV_{mean}$ < 50% had PR after CCRT (p = 0.026). Conclusion: The degree of metabolic changes measured by PET-CT during CCRT was predictive for NSCLC tumor response after CCRT.

PET/CT 검사에서 확대된 표시시야가 표준섭취계수에 미치는 영향 평가 (The Evaluation of the Difference of the SUV Caused by DFOV Change in PET/CT)

  • 곽인석;이혁;최성욱;석재동
    • 핵의학기술
    • /
    • 제15권2호
    • /
    • pp.13-20
    • /
    • 2011
  • PET/CT 검사에서 제한적인 CT (Computed Tomography)의 FOV (Field of View)는 PET 영상의 DFOV (Display FOV) 바깥부위에서 영상 잘림 현상 (truncation artifact)에 의한 오류를 유발할 수 있다. 본 논문에서는 영상 재구성 시 확대된 DFOV를 적용함에 따라 PET영상에서 표준섭취계수 (Standardization Uptake Value, SUV)의 차이를 측정하여 영상에 미치는 정도를 비교 평가하고 그 유용성을 알아보고자 하였다. 5.3 kBq/mL의 $^{18}F$(FDG)를 주입한 NEMA 1994 PET 모형을 FOV의 중앙에 위치하고 영상을 획득하고, 동일모형을 FOV의 바깥부분으로 위치를 변경하여 truncation 현상이 발생하도록 한 뒤 같은 방법을 적용하여 영상을 획득하였다. 각 실험을 통해 얻어진 데이터는 동일한 방법을 적용하여 영상을 재구성 하였으며, DFOV는 50 cm와 70 cm로 변경하여 각각 적용하였다. 그리고 방출영상에 관심영역을 설정하고 최대섭취계수($_{max}SUV$)를 비교 하였으며 육안적인 이상유무도 함께 확인하였다. 임상영상은 모형실험에서와 같이 truncation 현상이 발생한 환자군을 선정한 후 해당 환자의 방출영상에서 간(Liver) 부위에 관심영역을 설정하고 모형실험에서와 같이 영상 재구성 시 DFOV 변화에 따른 표준섭취계수의 차이를 비교 하였다. 모형을 FOV 내 중심에 위치시키고 시행한 실험에서 DFOV 증가에 따라 화소의 크기는 3.91 mm에서 5.47 mm로 증가하였고, 관심영역의 $_{max}SUV$는 각각 1.49에서 1.35로 나타나 확대된 DFOV 적용시 9.39%의 감소를 보였다. 모형을 FOV의 바깥부분으로 이동시킨 후 얻은 영상의 경우 $_{max}SUV$가 1.30에서 1.20로 7.69% 감소하였다. DFOV 확대로 인하여 추가적으로 나타난 부위에서의 $_{max}SUV$는 1.51이었고, truncation 현상이 발생한 부위를 기준으로 안쪽과 바깥쪽 부위의 $_{max}SUV$차이는 25.9%로 바깥쪽에서 높은 결과를 보였다. 임상영상의 확대된 DFOV를 적용한 경우 $_{max}SUV$ 3.38에서 3.13으로 7.39% 감소하였다. 확대된 DFOV를 적용할 경우에서의 $_{max}SUV$ 감소 현상은 화소 크기의 증가로 인해 화소 간 잡음 (Pixel to Pixel Noise)이 낮아져 발생하는 저평가 정도의 범위를 벗어나지 않았으며 확대된 부위의 영상에서 육안적 확인 시 선형인공산물 등의 이상이 발견되지 않아 truncation 현상 없는 영상을 얻을 수 있다는 점에서는 임상적 적용이 유용하다고 할 수 있다. 그러나 실제 환자에게 확대된 DFOV를 적용할 경우에는 영상면 전체에서 정량적 결과가 저평가 되는 것을 감안하여야 하며, 특히 확대되어 추가로 나타난 부위에서의 정량적 결과가 높게 나타날 수 있다는 점에 유의하여 적용해야 할 것이다.

  • PDF

PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교 (A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT)

  • 이승재;박훈희;안샤론;오신현;남궁혁;임한상;김재삼;이창호
    • 핵의학기술
    • /
    • 제12권3호
    • /
    • pp.235-240
    • /
    • 2008
  • PET/CT 검사의 사용 초기에 CT는 주로 감쇠보정(Attenuation Correction: AC)의 목적으로 사용되어졌지만, CT의 성능이 향상됨으로써 조영제를 이용한 CT검사를 진단에 반영하여 보다 진보된 진단적 가치를 가질 수 있게 되었다. 조영제의 사용이 없이도 CT를 판독할 수 있지만 병변의 정확한 범위를 확인하고 정상 구조물을 구별하는데 있어서 조영제의 사용은 판독자로 하여금 판독을 매우 용이하게 하는 도움을 줄 수 있다. 하지만, 그동안 PET/CT검사 시 조영제가 감쇠보정에 영향을 줄 수 있다는 논쟁으로 이견이 많았다. 40-140 keV 정도의 낮은 엑스선을 이용하는 CT영상에 비하여, 조영제를 사용한 CT영상에서는 조영제로 인해 감쇠가 많이 되지만 511 keV의 에너지를 가진 감마선은 조영제로 인해 거의 영향을 받지 않게 되고 이로 인해 감쇠보정 시 과보정을 하게 되어 PET영상에서 오류를 나타낼 수 있다는 의견이 보고되기도 하였다. 이와는 반대로 조영제가 감쇠보정에 과대평가를 가져올 수 있다는 의견과 과보정으로 인한 표준화섭취계수에 변화의 가능성은 있으나 결정적인 영향을 미치지 않는다는 의견도 제시되었다. 본 연구에서는 조영제의 영향이 SUV에 어떠한 영향을 미치는지에 대해서만 비교 평가하였다. 2007년 12월에서 2008년 6월 사이에 본원에서 PET/CT 검사를 시행한 환자 중 요오드 조영제에 대한 부작용이 없고 당뇨병이 없는 진행성 암 환자 30명을 대상으로 하였으며, DSTe (General Electric Healthcare, Milwaukee, MI, USA)를 사용하여, 각각의 환자는 조영제를 사용하지 않은 CT를 시행한 후 PET영상을 얻었고 그 후, 조영제를 사용한 CT검사를 하였다. 각각의 CT정보로 감쇠보정을 실시, 종류별로 PET영상을 획득하여, 각 영상에 동일한 관심영역(Region of Interests : ROIs)을 설정 후, SUV를 비교 하였다. 얻어진 두 가지 결과 값의 정량 분석의 비교를 위해서 대응표본 T-검정 (Paired t-test)을 사용하였다. 검사를 시행한 30명의 환자에게서 폐, 간, 심장의 $SUV_{max}$ 값과 $SUV_{mean}$값을 측정하여 총 180개 영역을 분석하였다. 조영제를 사용하기 전과 후를 비교하였을 때, 측정한 거의 모든 영역에서 조영 후의 $SUV_{max}$$SUV_{mean}$가 상승하였고 통계적으로도 유의한 것으로 나타났다(p value<0.05). 심장 영역에서 조영 전 보다 조영 후의 $SUV_{mean}$값이 증가된 것으로 나타났지만, 통계적으로 유의하게 나타나지는 않았다. 조영제를 사용한 CT영상의 SUV값이 과보정되어, 조영제를 사용하지 않은 CT의 SUV 보다 높게 나왔으나 기존의 보고된 논문에서는 이와 같은 결과는 실제 임상 판독에 있어서 큰 영향을 미치지 않는다고 보고되어 있다. 그러나 원발성병변의 진행을 알아보는 과정에서는 SUV의 작은 변동도 분명 영향을 줄 수 있으므로 간 영역과 같이 SUV의 변동이 다른 영역에 비해 상대적으로 큰 영역에서는 수치의 변화에 대한 주의가 요구 될 것으로 사료된다.

  • PDF

양전자단층촬영장치에서 호흡의 영향에 따른 종양의 변화 분석 (Defining the Tumour and Gross Tumor Volume using PET/CT : Simulation using Moving Phantom)

  • 진계환
    • 한국방사선학회논문지
    • /
    • 제15권7호
    • /
    • pp.935-942
    • /
    • 2021
  • 호흡에 의한 체내 장기의 불수의적 움직임은 방사선 치료 및 진단의 결과에 큰 영향을 주는 요소이다. 본 논문에서는 호흡에 따른 장기 또는 종양의 움직임을 모사하기 위한 움직임 팬텀을 제작하고 다양한 호흡모사 조건에서 18F-FDG PET 스캔 영상을 획득하여 호흡에 따른 종양의 움직임 범위와 종양의 크기에 따른 인공물의 수준 및 표준섭취계수 최대값(maximum standardized uptake value, SUVmax)를 분석하였다. 운영체계로 윈도우 CE(Windows CE) 6.0 기반으로 전동액추에이터, 전동액추에이터 포지셔닝 드라이버, PLC(Programmable Logic Controller)을 이용한 위치 및 속도 조절 모듈은 이동거리 0-5 cm와 왕복이동 10회, 15회, 20회에서 정상적으로 동작하였다. 지연시간 100분에서 구의 지름 10, 13, 17, 22, 28, 37mm일 때 각각 80.4, 99.5, 107.9, 113.1, 128.0, 124.8%로 측정되었다. 이동거리가 같을 때 호흡수에 따른 차이는 미미하였다. 호흡수를 20회 하고 이동거리를 1 cm, 2 cm, 3 cm, 5 cm일 때 구의 지름이 10, 13, 17, 22, 28, 37 mm에서 이동거리가 길어질수록 구의 크기가 작은 것 부터영상의 구분 능력이 저하되었다. 정지영상에 비하여 이동거리를 5 cm로 하였을 때, 표준섭취계수의 최대값은 구의 지름이 10, 13, 17, 22, 28, 37 mm에서 각각 18.0%, 23.7%, 29.3%, 38.4%, 49.0%, 67.4%이었다.

Comparison of Positron Emission Tomography(PET) imaging-based initial in vivo pharmacokinetics by administration routes of [18F]FDG

  • Yiseul Choi;Jang Woo Park;Eun Sang Lee;Ok-Sun Kim;Hye Kyung Chung
    • 대한방사성의약품학회지
    • /
    • 제7권2호
    • /
    • pp.99-103
    • /
    • 2021
  • In this study, the initial in vivo pharmacokinetic changes according to the routes of drug administration were investigated using bioimaging techniques. The purpose of this study was to quantify the degree of distribution of each major organ in normal mice over time by acquiring Positron Emission Tomography/Computed Tomography images while administering routes F-18 fluorodeoxyglucose such as intravenous, intraperitoneal and per oral, a representative diagnostic radiopharmaceutical. Dynamic Positron Emission Tomography images were acquired for 90 minutes after drug administration. Radioactivity uptake was calculated for major organs using the PMOD program. In the case of intravenous administration, it was confirmed that it spread quickly and evenly to major organs. Compared to intravenous administration, intraperitoneal administration was about three times more absorbed and distributed in the liver and intestine, and it was showed that the amount excreted through the bladder was more than twice. In the case of oral administration, most stayed in the stomach, and it was showed that it spread slowly throughout the body. In comparison with intravenous administration, it was presented that the distribution of kidneys was more than 9 times and the distribution of bladder was 66% lower. Since there is a difference in the initial in vivo distribution and excretion of each administration method, we confirmed that the determination of the administration route is important for in vivo imaging evaluation of new drug candidates.