The study on the scattering ratio at the edge of the block according to the increasing block thickness in electron therapy (전자선 치료 시 차폐블록 두께 변화에 따른 블록 주변 선량에 관한 연구)

  • Park, Zi On;Gwak, Geun Tak;Park, Ju Kyeong;Lee, Seung Hun;Kim, Yang Su;Kim, Jung Soo;Kwon, Hyoung Cheol;Lee, Sun Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.57-65
    • /
    • 2019
  • Purpose: The purpose is to clarify the effect of additional scattering ratio on the edge of the block according to the increasing block thickness with low melting point lead alloy and pure lead in electron beam therapy. Methods and materials: $10{\times}10cm^2$ Shielding blocks made of low melting point lead alloy and pure lead were fabricated to shield mold frame half of applicator. Block thickness was 3, 5, 10, 15, 20 (mm) for each material. The common irradiation conditions were set at 6 MeV energy, 300 MU / Min dose rate, gantry angle of $0^{\circ}$, and dose of 100 MU. The relative scattering ratio with increasing block thickness was measured with a parallel plate type ion chamber(Exradin P11) and phantom(RW3) by varying the position of the shielding block(cone and on the phantom), the position of the measuring point(surface ans depth of $D_{max}$), and the block material(lead alloy and pure lead). Results : When (depth of measurement / block position / block material) was (surface / applicator / pure lead), the relative value(scattering ratio) was 15.33 nC(+0.33 %), 15.28 nC(0 %), 15.08 nC(-1.31 %), 15.05 nC(-1.51 %), 15.07 nC(-1.37 %) as the block thickness increased in order of 3, 5, 10, 15, 20 (mm) respectively. When it was (surface / applicator / alloy lead), the relative value(scattering ratio) was 15.19 nC(-0.59 %), 15.25 nC(-0.20 %), 15.15 nC(-0.85 %), 14.96 nC(-2.09 %), 15.15 nC(-0.85 %) respectively. When it was (surface / phantom / pure lead), the relative value(scattering ratio) was 15.62 nC(+2.23 %), 15.59 nC(+2.03 %), 15.53 nC(+1.67 %), 15.48 nC(+1.31 %), 15.34 nC(+0.39 %) respectively. When it was (surface / phantom / alloy lead), the relative value(scattering ratio) was 15.56 nC(+1.83 %), 15.55 nC(+1.77 %), 15.51 nC(+1.51 %), 15.42 nC(+0.92 %), 15.39 nC(+0.72 %) respectively. When it was (depth of $D_{max}$ / applicator / pure lead), the relative value(scattering ratio) was 16.70 nC(-10.87 %), 16.84 nC(-10.12 %), 16.72 nC(-10.78 %), 16.88 nC(-9.93 %), 16.90 nC(-9.82 %) respectively. When it was (depth of $D_{max}$ / applicator / alloy lead), the relative value(scattering ratio) was 16.83 nC(-10.19 %), 17.12 nC(-8.64 %), 16.89 nC(-9.87 %), 16.77 nC(-10.51 %), 16.52 nC(-11.85 %) respectively. When it was (depth of $D_{max}$ / phantom / pure lead), the relative value(scattering ratio) was 17.41 nC(-7.10 %), 17.45 nC(-6.88 %), 17.34 nC(-7.47 %), 17.42 nC(-7.04 %), 17.25 nC(-7.95 %) respectively. When it was (depth of $D_{max}$ / phantom / alloy lead), the relative value(scattering ratio) was 17.45 nC(-6.88 %), 17.44 nC(-6.94 %), 17.47 nC(-6.78 %), 17.43 nC(-6.99 %), 17.35 nC(-7.42 %) respectively. Conclusions: When performing electron therapy using a shielding block, the block position should be inserted applicator rather than the patient's body surface. The block thickness should be made to the minimum appropriate shielding thickness of each corresponding using energy. Also it is useful that the treatment should be performed considering the influence of scattering dose varying with distance from the edge of block.

수직방향으로 적층된 InAs 양자점의 광학적 특성

  • 김광무;노정현;박영민;박용주;나종범;김은규;방정호
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.93-93
    • /
    • 1999
  • 양자점(Quantum dot : QD)를 이용한 소자를 만들기 위해서는 수직방향으로의 적층이 필수적이다. 양자점의 적층은 수직적으로 같은 위치에 정렬하므로, 고려되어야 할 요소로는 양자점간의 파동함수의 중첩(coupling)에 의한 특성변화, 적층의 진행에 따른 변형(strain)의 증가로 기인되는 volcano 모양으로 나타나는 결함등이 있다. 이러한 결함은 nonradiative recombination center로 작용하여 오히려 효율이 떨어지게 되는 현상이 발생하게 되므로 본 연구에서는 적층횟수에 따른 발광효율의 변화를 조사하여 소자응용에 적절한 적층 조건을 조사하였다. 시료성장은 molecular beam epitaxy (MBE) 장치를 이용하여 GAs(100) 기판위에 GaAs buffer를 58$0^{\circ}C$에서 150nm 성장후 InAs/GaAs 양자점과 50$0^{\circ}C$에서 적층회수 1, 3, 6, 10, 15, 20회로 하였으며 적층성장 이후 GaAs cap layer를 성장하였다. GaAs spacing과 cap layer의 성장온도 역시 50$0^{\circ}C$이며 시료의 분석은 photoluminescence (PL)과 scanning transmission electron microscope (STEM)으로 하였다. 적층횟수를 바꾸어 시료를 성장하기 전에 적층횟수를 10회로 고정하고 spacing 두께를 2.8nm, 5.6nm, 11.2nm로 바꾸어 성장하여 PL 특성을 관찰하여본 결과 spacing이 2.8nm인 경우 수직적으로 정렬된 양자점 간에 coupling이 매우 커서 single layer QD의 PL peak에 비해 약 100nm 정도 파장이 증가하였고, spacing의 두께가 11.2nm 일 경우는 single layer QD와 거의 같은 파장의 빛을 방출하여 중첩이 거의 일어나지 않지만 두꺼운 spacing때문에 PL세기가 감소하였다. 한편, 적층회수에 따른 광학적 특성을 PL로 조사하여 본 결과 peak 파장은 적층횟수가 1회에서 3회로 증가했을 때는 blue shift 하다가 이후 적층이 증가함에 따라 red shift 하였다. 그리고 10층 이상의 적층에서는 excited state에서 기인된 peak이 검출되었다. 이렇나 원인은 적층수가 증가함에 따라 carrier life time이 증가하여 exciter state에 carrier가 존재할 확률이 증가하기 때문으로 생각된다. 또한 PL 세기가 다소 증가하다가 10층 이상의 경우는 다시 감소함을 알 수 있었다. 반치폭도 3층과 6층에서 가장 적은 값을 보였다. 이와 같은 결과는 결함생성과 관련하여 STEM 분석으로 해석되어질 수 있는데 6층 적층시는 양자점이 수직적으로 정렬되어 잘 형성됨을 관찰할 수 있었고 적층에 따른 크기 변화도 거의 나타나지 않았다. 그러나 10층 15층 적층시 몇가지 결함이 형성됨을 볼수 있었고 양자점의 정렬도 완전하게 이루어지지 않음을 볼 수 있었다. 그러므로 수직적층된 InAs 양자점의 광학적 특성은 성장조건에 따른 결함생성과 밀접한 관련이 있으며 상세한 논의가 이루어질 것이다.

  • PDF

Late Rectal Complication in Patients treated with High Dose Rate Brachytherapy for Stage IIB Carcinoma of the Cervix (FIGO병기 IIB 자궁경부암에서 고선량 강내 방사선치료후의 후기 직장 합병증)

  • Chung, Eun-Ji;Kim, Gwi-Eon;Suh, Chang-Ok;Keum, Ki-Chang;Kim, Woo-Cheol
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.41-52
    • /
    • 1996
  • Purpose : This paper reports a dosimetric study of 88 patients treated with a combination of external radiotherapy and high dose rate ICR for FIGO stage IIB carcinoma of the cervix. The purpose is to investigate the correlation between the radiation doses to the rectum, external radiation dose to the whole pelvis, ICR reference volume, TDF BED and the incidence of late rectal complications, retrospectively. Materials and Methods : From November 1989 through December 1992, 88 patients with stage IIB cervical carcinoma received radical radiotherapy at Department of Radiation Oncology in Yonsei University Hospital. Radiotherapy consisted of 44-54 Gy(median 49 Gy) external beam irradiation plus high dose rate intracavitary brachytherapy with 5 Gy per fraction twice a week to a total dose of 30 Gy on point A. The maximum dose to the rectum by contrast(r, R) and reference rectal dose by ICRU 38(dr, DR) were calculated. The ICR reference volume was calculated by Gamma Dot 3.11 HDR planning system, retrospectively The time-dose factor(TDF) and the biologically effective dose (BED) were calculated. Results : Twenty seven($30.7\%$) of the 88 patients developed late rectal complications:12 patients($13.6\%$) for grade 1, 12 patients($13.6\%$) for grade 2 and 3 patients($3.4\%$) for grade 3. We found a significant correlation between the external whole pelvis irradiation dose and grade 2, 3 rectal complication. The mean dose to the whole pelvis for the group of patients with grade 2, 3 complication was Higher, $4093.3\pm453.1$ cGy, than that for the patients without complication, $3873.8\pm415.6$ (0.05$7163.0\pm838.5$ cGy, than that for the Patients without rectal complication, $0772.7\pm884.0$ (p<0.05). There was no correlation of the rate of grade 2, 3 rectal complication with the iCR rectal doses(r, dr), ICR reference volume, TDF and BED. Conclusion : This investigation has revealed a significant correlation between the dose calculated at the rectal dose by ICRU 38(DR) or the most anterior rectal dose by contrast(R) dose to the whole pelvis and the incidence of grade 2, 3 late rectal complications in patients with stage IIB cervical cancer undergoing external beam radiotherapy and HOR ICR. Thus these rectal reference points doses and whole pelvis dose appear to be useful Prognostic indicators of late rectal complication in high dose rate ICR treatment in cervical carcinoma.

  • PDF

Postoperative External Beam Radiotherapy for Medulloblastoma (수아세포종의 수술 후 외부 방사선치료)

  • Chun, Ha-Chung;Lee, Myung-Za
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.101-106
    • /
    • 2000
  • Purpose : This study was peformed to evaluate the effectiveness and tolerance of craniospinal irradiation for patients with modulloblastoma and to define the optimal radiotherapeutic regimen. Materials and Methods : We retrospectively analyzed the records of 43 patients with modulloblastoma who were treated with external beam craniospinal radiotherapy at our institution between May, 1984 and April, 1998. Median follow up period was 47 months with range of 18 to U months. Twenty seven patients were male and sixteen patients were female, a male to female ratio of 1.7:1. Surgery consisted of biopsy alone in 5 patients, subtotal excision in 24 patients, and gross total excision in 14 patients. All of the patients were treated with craniospinal irradiation. All of the patients except four received at least 5,000 cGy to the posterior fossa and forty patients received more than 3,000 cGy to the spinal cord. Results : The overall survival rates at 5 and 7 years for entire group of patients were 57$\%$ and 56$\%$, respectively. Corresponding disease free survival rates were 60$\%$ and 51$\%$, respectively, The rates of disease control in the posterior fossa were 77$\%$ and 67$\%$ at 5 and 7 years. Gross total excision and subtotal excision resulted in 5 year overall survival rates of 76$\%$ and 66$\%$, respectively, In contrast, those patients who had biopsy alone had a 5 year survival rate of only 40$\%$. Posterior fossa was a component of failure in 11 of the 18 recurrences. Seven recurrences were isolated to the posterior fossa. Four patients had neuraxis recurrences, three had distant metastasis alone and four had multiple sites of failure, all involving the primary site. Conclusion : Craniospinal irradiation for patients with moduiloblastoma is an effective adjuvant treatment without significant treatment related toxicitles. There is room for Improvement in terms of posterior fossa control, especially in biopsy alone patients. The advances in radiotherapy including hypefractionation, stereotactic radiosurgery and 3D conformal radiotherapy would be evolved to improve the tumor control rate at primary site.

  • PDF

Analysis of the Range Verification of Proton using PET-CT (Off-line PET-CT를 이용한 양성자치료에서의 Range 검증)

  • Jang, Joon Young;Hong, Gun Chul;Park, Sey Joon;Park, Yong Chul;Choi, Byung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.101-108
    • /
    • 2017
  • Purpose: The proton used in proton therapy has a characteristic of giving a small dose to the normal tissue in front of the tumor site while forming a Bragg peak at the cancer tissue site and giving up the maximum dose and disappearing immediately. It is very important to verify the proton arrival position. In this study, we used the off-line PET CT method to measure the distribution of positron emitted from nucleons such as 11C (half-life = 20 min), 150 (half-life = 2 min) and 13N The range and distal falloff point of the proton were verified by measurement. Materials and Methods: In the IEC 2001 Body Phantom, 37 mm, 28 mm, and 22 mm spheres were inserted. The phantom was filled with water to obtain a CT image for each sphere size. To verify the proton range and distal falloff points, As a treatment planning system, SOBP were set at 46 mm on 37 mm sphere, 37 mm on 28 mm, and 33 mm on 22 mm sphere for each sphere size. The proton was scanned in the same center with a single beam of Gantry 0 degree by the scanning method. The phantom was scanned using PET-CT equipment. In the PET-CT image acquisition method, 50 images were acquired per minute, four ROIs including the spheres in the phantom were set, and 10 images were reconstructed. The activity profile according to the depth was compared to the dose profile according to the sphere size established in the treatment plan Results: The PET-CT activity profile decreased rapidly at the distal falloff position in the 37 mm, 28 mm, and 22 mm spheres as well as the dose profile. However, in the SOBP section, which is a range for evaluating the range, the results in the proximal part of the activity profile are different from those of the dose profile, and the distal falloff position is compared with the proton therapy plan and PET-CT As a result, the maximum difference of 1.4 mm at the 50 % point of the Max dose, 1.1 mm at the 45 % point at the 28 mm sphere, and the difference at the 22 mm sphere at the maximum point of 1.2 mm were all less than 1.5 mm in the 37 mm sphere. Conclusion: To maximize the advantages of proton therapy, it is very important to verify the range of the proton beam. In this study, the proton range was confirmed by the SOBP and the distal falloff position of the proton beam using PET-CT. As a result, the difference of the distally falloff position between the activity distribution measured by PET-CT and the proton therapy plan was 1.4 mm, respectively. This may be used as a reference for the dose margin applied in the proton therapy plan.

  • PDF

The Results of Curative Radiation Therapy for 49 Patients of the Uterine Cervical Carcinomas (자궁 경부암의 근치적 방사선 치료 효과 -49예의 분석 -)

  • Ryu Mi Ryeong;Kim Yeon Sil;Choi Byung Ock;Yoon Sei Chul;Shinn Kyung Sub;Namkoong Sung Eun;Kim Seung Jo
    • Radiation Oncology Journal
    • /
    • v.10 no.2
    • /
    • pp.219-225
    • /
    • 1992
  • Fifty patients with carcinoma of the uterine cervix received curative radiotherapy by external irradiation of the whole pelvis and intracavitary radiation at the Department of Therapeutic Radiology, Kangnam St. Mary's Hospital from September, 1983 to October, 1986. External beam whole pelvic irradiation was done first up to 4500-5940 cGy in 5 weeks to 6.5 weeks, followed by an intracavitary radiation. Total dose of radiation to point A varied from 6500 cGy to 11344 cGy (average 6764 cGy). Of the 50 patients, one patient was lost to follow up and follow up period of the remaining 49 patients ranged from 3 months to 93 months (median 32 months). According to FIGO classification, 6 ($12.2\%$) were in stage Ib, 6 ($12.2\%$) in stage IIa, 25 ($51\%$) in stage IIb, 7 ($14\%$) in stage III, and 5 ($10.2\%$) in stage IV. Age of the patients ranged from 33 to 76 years (median 60 years). Pathologically, fourty six ($94\%$) patients had squamous cell carcinoma, 2 ($4\%$) had adenocarcinoma, and 1 ($2\%$) had adenosquamous cell carcinoma. Overall response rate was $84\%$. 5-year survival rate was $49\%$ for entire group ($75\%$ for stage Ib, $83\%$ for Stage IIa, $42.5\%$ for stage IIb, $25\%$ for stage III, $40\%$ for stage IV). Complications were observed in 11 ($22.4\%$) patients, who revealed rectal complications with most common frequency. Others were self limiting trifle ones such as wet desquamation, fatigue, mild leukopenia, etc. The correlation of the survival rate with various factors (age, dose, Hb level, pelvic lymph node status, performance status, local recurrence) was evaluated but showed no statistical significance except the age and local recurrence in this series; survival of patients less than 50 years of age was worse than that of the older, and the presence of local recurrence had worse prognosis (p<0.05).

  • PDF

Influence of Regularization Parameter on Algebraic Reconstruction Technique (대수적 재구성 기법에서 정규화 인자의 영향)

  • Son, Jung Min;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.679-685
    • /
    • 2017
  • Computed tomography has widely been used to diagnose patient disease, and patient dose also increase rapidly. To reduce the patient dose by CT, various techniques have been applied. The iterative reconstruction is used in view of image reconstruction. Image quality of the reconstructed section image through algebraic reconstruction technique, one of iterative reconstruction methods, was examined by the normalized root mean square error. The computer program was written with the Visual C++ under the parallel beam geometry, Shepp-Logan head phantom of $512{\times}512$ size, projections of 360, and detector-pixels of 1,024. The forward and backward projection was realized by Joseph method. The minimum NRMS of 0.108 was obtained after 10 iterations in the regularization parameter of 0.09-0.12, and the optimum image was obtained after 8 and 6 iterations for 0.1% and 0.2% noise. Variation of optimum value of the regularization parameter was observed according to the phantom used. If the ART was used in the reconstruction, the optimal value of the regularization parameter should be found in the case-by-case. By finding the optimal regularization parameter in the algebraic reconstruction technique, the reconstruction time can be reduced.

The Actual State and the Utilization for Dental Radiography in Korea (국내 치과방사선의 현황 및 이용 실태)

  • Shin, Gwi-Soon;Kim, You-Hyun;Lee, Bo-Ram;Kim, Se-Young;Lee, Gui-Won;Park, Chang-Seo;Park, Hyok;Chang, Kye-Yong
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.109-120
    • /
    • 2010
  • The purpose of this study was first to analyze the utilization of dental examination through questionnaire to develop a diagnostic reference level of patient doses for dental radiography in korea. 77 dental institutions were classified into three groups: A group for the dental hospitals of the college of dentistry (11 institutions), B group for dental hospitals (30 institutions) and C group for dental clinics (36 institutions). The results were as follows : The mean numbers of unit chairs and medical staffs were 140.2, 15.3 and 5.8 sets, 112.6, 7.3 and 1.7 dentists, 3.1, 0.5 and no one radiologic technologists, and 19.7, 12.5 and 3.3 dental hygienists in A, B and C groups, respectively. The mean numbers of dental X-ray equipments were 14.64, 3.21 and 2.19 in A, B and C groups, respectively. Intraoral dental X-ray unit was used the most, the following equipments were panoramic, cephalometric, and cone-beam CT units. The most used X-ray imaging system was also digital system (above 50%) in all three groups. Insight dental film (Kodak, USA) having high sensitivity was routinely used for periapical radiography. The automatic processor was not used in many dental institutions, but the film-holding device was used in many dental institutions. The utilization rates of PACS in A, B and C groups were 90.9%, 83.3% and 16.7% respectively, and the PACS software program was used the most PiView STAR (Infinitt, Korea). The annual mean number of radiographic cases in one dental institution in 2008 for A group was 6.8 times and 21.2 times more than those for B and C groups, and periapical and panoramic radiographs were taken mostly. Tube voltage (kVp) and tube current (mA) for periapical radiography were similar in all three groups, but exposure time in C group was 12.0 times and 3.5 times longer than those in B and C groups. The amount of radiation exposure in C group, in which dental hygienists take dental radiographs, was more than those in other groups. The exposure parameters for panoramic radiography were similar in all three groups. In conclusion, the exposure parameters in dental radiography should be determined with reference level, not past experiences. Use of automatic processor and film-holding devices reduces the radiation exposure in film system. The quality assurance of dental equipments are necessary for the reduction of the patient dose and the improvement of X-ray image quality.

Effect of Radiotherapy on Chromosomal Aberration in Cancer Patients (암환자에서 방사선치료에의한 염색체이상)

  • Chun, Ha-Chung;Lee, Myung-Za;Yoo, Myung-Soo
    • Radiation Oncology Journal
    • /
    • v.11 no.1
    • /
    • pp.43-50
    • /
    • 1993
  • We evaluated frequency and types of chromosomal aberrations by ionizing radiation in cancer patients treated with radiotherapy in our institution. Twenty-five patients with various types of carcinomas such as lung, uterine cervix, esophagus, rectum, head and neck and pancreatic cancers were studied immediately before and after external beam radiotherapy. The frequency of aberrant metaphase prior to treatment was $4.93{\%}$, which was higher than that of control group. Especially in lung cancer, the freuqency of aberrant metaphase was three times higher than control group. A comparison of chromosomal abnormalities observed before and after radiotherapy demonstrated that proportion of aberrant rnetaphases was significantly inreased to $22.13{\%}$. Major chromosomal aberrations like structural abnormalities showed remarkalbe increase from 65.45 to $88.45{\%}$ after the treatment. Also the numbers of chromosomal alterations per cell were increased by a factor of 6.5. Aberrations with two or more break points were more prominently increased, compared with aberrations with single break point. The number of chromosomal break points was noted to be higher than expected value in No.1, 3, 8 and 11 chromosomes and lower in No.13, 15, 17 and 21 chromosomes. Based on this study, we believe that the distribution of chromosomal breakage is related with gene and chromosomal rearrangement which could result in the development of cancers.

  • PDF

Side-Aspect Target Strength Measurement of Swimbladdered Fish Using Multi-Frequencies System: Black Sea Bream (Acanthopagrus schlegeli)

  • Cho, Sung-Ho;Kang, Don-Hyug;Na, Jung-Yul;Myoung, Jung-Goo;Kim, Jong-Man
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.3E
    • /
    • pp.101-109
    • /
    • 2006
  • Besides dorsal-aspect target strength (TS) of the fish, side-aspect TS information is also acoustically important parameter in fisheries acoustics. In this study, the side-aspect TS of 11 black sea bream (Acanthopagurus schlegeli) were measured using a split beam echosounder of 120, 200, and 420 kHz; total length of the fish ranged from 12.4 to 23.7 cm, and wet weight from 27.5 to 229.8g. For the precise TS measurement with side-aspect angle, we used anesthetized and tethered specimens of known size while being rotated through $360^{\circ}C$ by means of a carousel structure. The side-aspect TS measurements of the fish were conducted by rotating the fish in the horizontal plane at 50 interval. The ping interval was 0.2 second and elapsed time at each angle was 30-60 second. As a result, the measured side-aspect TS data were fitted by sinusoidal function. The relationships between fish length and near full side-aspect TS were as follows: $TS_{120kHz}= 21.46 log (TL)-67.5 (r = 0.70), \;TS_{200 kHz}= 31.03 log (TL)-76.9 (r=0.83),\;TS_{420 kHz}= 30.79 log (TL)-72.2 (r = 0.77)$. For comparison, theoretically estimated side-aspect TS from the Kirchhoff ray mode (KRM) model, which based on swimbladder and body morphology, were compared with the measured TS.