• 제목/요약/키워드: $\rho$-power

검색결과 351건 처리시간 0.031초

수영과 저출력 레이저 치료가 Freund's Complete Adjuvant 유발 흰쥐의 관절염 치유에 미치는 영향 (The Effect of Swimming and Low Power Laser on the Healing of the Freund's Complete Adjuvant Induced Arthritis in Rat)

  • 박미희;김재영;노민희
    • The Journal of Korean Physical Therapy
    • /
    • 제18권3호
    • /
    • pp.47-58
    • /
    • 2006
  • Purpose: This study was to find that what mechanism take effects that was Adjuvant Induced Arthritis in Sprague-Dawley rat and then treated the swimming and low power laser. Methods: Adjuvant Induced Arthritis was induced 24 Sprague-Dawley rat by the subcutaneous injection of a 0.2ml Freund's Complete Adjuvant into the right hind paw and right knee joint. Second injection used of 0.05ml Freund's Complete Adjuvant by same method. Arthritic rat were divided 3 groups; arthritic swimming group, arthritic laser group and case control group. The author performed several experimental tests which were the hind paw thickness, step length, knee joint space, activity of enzyme. Results: Hind paw thickness decreased in swimming and laser group. Left step length and knee joint space increased in swimming and laser. Conclusion: Swimming and low power laser therapy on the Adjuvant Induced Arthritis in rats does effective for the rheumatic arthritis therapy by decrease of hind paw thickness, increase of opposite side step length, increase of activity of albumin and IgG and increase of knee joint space.

  • PDF

차세대전력공급네트워크(Micro-grid)의 운용제어앨고리즘 (An Operation and Control Algorithm of Micro-grid)

  • 노대석;김재언
    • 한국산학기술학회논문지
    • /
    • 제8권2호
    • /
    • pp.232-239
    • /
    • 2007
  • 전력산업의 구조개편과 더불어 분산전원의 배전계통연계운용 및 전력품질이 전력회사의 배전사업자, 구역전기사업자, 전기공급 신뢰도와 밀접한 관계에 있는 산업용 수용가들에게 많은 관심을 불러일으키고 있다. 최근, 이러한 주변정세는 차세대의 배전계통이 다수의 차세대 전력공급네트워크(Micro-grid)들로 구성될 것이라고 하는 예상을 전문가들로부터 제기되기에 이르렀다. 그러나, 제안된 Micro-grid는 몇몇의 분산전원과 전력품질을 보상하는 기기, 그리고 통신제어설비와 부하들로 구성된다는 기본적인 내용에 지나지 않는다. 따라서, 본 논문에서는 수용가에 고신뢰 고품질의 전력공급을 가능하게 하는 차세대 전력공급네트워크인 Micro-grid의 Topology와 그 운전제어앨고리즘을 제안한다.

  • PDF

규제완화된 전력시장 하에서의 전력계통 신뢰도를 고려한 경제부하배분 (Economic Load Dispatch Considering Power System Reliability under the Deregulated Electricity Market)

  • 김홍식;임채현;최재석;차준민;노대석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.391-393
    • /
    • 2000
  • This paper presents an new algorithm for the economic load dispatch considering the reliability level constraints of composite power system under deregulated electricity market. It is the traditional ELD problem that generation powers have been dispatched In order to minimize total fuel cost subjected to constraints which sum of powers generated must equal the received load and no violating lower and upper limit constraints on generation. Under deregulated electricity market, however, generation powers of a pool have to be reallocated newly in order to satisfy the reliability differentiated level required at a load point because of a reliability differentiated electricity service which is a part of the priority service. In this study, new economic load dispatch algorithm for reallocating the generation powers of a pool in order to satisfy the reliability differentiated level under deregulated competitive electricity market is proposed. The uncertainties of not only generators but also transmission lines are considered fer the reliability evaluation. The characteristics and effectiveness of this methodology are illustrated by the case studies on MRBTS and IEEE-RTS.

  • PDF

고압배전선로용 선로전압조정장치(SVR)의 최적 도입방안에 관한 연구 (A Study on the Optimal Introduction of Step Voltage Regulator(SVR) in Distribution Feeders)

  • 이은미;김미영;노대석;손상욱;김재언;박창호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권11호
    • /
    • pp.610-618
    • /
    • 2004
  • With the development of industry and the improvement of living standards, better quality in power electric service is required more than ever before. Under these circumstances, to deliver reasonable voltage regulation methods in distribution systems need to be developed. So, This paper deals with optimal introduction of the line voltage regulator (SVR : Step Voltage Regulator) in power distribution systems. First, This paper investigates characteristics of SVR and performs economic evaluation of SVR's introduction by using Present Worth Method. This paper, also suggests proper location and optimal voltage regulation algorithm. In order to deliver suitable voltages to as many customers as possible, the optimal sending voltage of SVR should be decided by the effective operation of voltage regulators at the distribution feeders. The simulation results using a model distribution system and real distribution systems show that the proposed methods can be a practical tool for the voltage regulation in distribution systems.

가관측성을 고려한 전력개통 상태추정을 위한 측정점선정 알고리즘에 관한 연구 (A Study on Measurement Selection Algorithm for Power System State Estimation Under the Consideration of Observability)

  • 이태식;이응혁;노태훈;홍효식;국현종;문영현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.523-526
    • /
    • 1995
  • This paper presents an improved algorithm of optimal measurement system design with a reliability evaluation method for a large power system. The proposed algorithm is developed to cosider the observability and to achieve highest accuracy of the state estimator as well with the limited investment cost. When the effect on these dummy bus measurements is considered in the proposed algorithm the other errors in the power system is also detected and then analyzed until to achieve the limited values. By taking advantage of the matrix sparsity and the optimal bus ordering the memory and the time are successfully reduced in the P/C's and workstation's model. The improved program is successfully tested for IEEK sample system and KEPCO system with PSS/E lineflow calculated data package.

  • PDF

전력 계통 축약을 위한 등가 제어기 모델에 관한 연구 (A study on equivalent control device model for power system reduction)

  • 이한민;노규민;장병훈;권세혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.273-275
    • /
    • 1999
  • This paper presents a dynamic equivalencing method in large electric power system for stability analysis. This method of modeling simplified equivalents for parts of the network outside the study area is to evaluate the stability of a study area modeled in detail. Generators are closely coupled in an electrical sense tend to swing together in groups during disturbances, and this behavior can be exploited to reduce the size of the power system model. The characteristics of generators swing together are referred to as coherency Coherency groups whose generators state trajectory are similar to the other generators state trajectory in the same coherency group by a certain disturbance. In this paper, procedures for forming dynamic equivalents of control devices of coherency-based generating units are proposed and the aggregation of the control devices such as excitation system and governor-turbine system is accomplished by this method. This method can deal with the aggregation of the same type of control devices and combination of hydro and steam unit or the many types of excitation systems. etc. This method is shown to be efficient in reducing the number of control device of generating units with small error in the study group by result of case study presented latter part of this paper.

  • PDF

CFD를 이용한 수직축 터빈 설계 및 유동특성 분석 (Vertical Axis Tidal Turbine Design and CFD hydrodynamic Analysis)

  • 조철희;고광오;이준호;노유호;이강희
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.159.1-159.1
    • /
    • 2011
  • Due to the global warming, the need to secure the alternative resources has become more important worldwide. Having very strong current on the west coast with up to 10 m tidal range, there are many suitable sites for the application of TCP(Tidal current power) in Korea. Not only from the current produced from the high tidal range, but also it can be widely applied to the offshore jetties and piers. The VAT(Vertical axis turbine) system could be very effective tidal device to extract the energies from the attacking flow to the structures. For the relatively slow current speed, the VAT system could be more effective application than HAT(Horizontal axis turbine) device. The performance of VAT can be evaluated by various parameters including number of blades, shape, sectional size, diameters and etc. The paper introduces the multi-layer vertical axis tidal current power system with savonius turbine. The turbine was designed with consideration of optimal blade numbers and the performance was simulated by CFD analysis.

  • PDF

NREL 풍력터빈 블레이드 20% 축소모델 풍동시험 결과 (Wind tunnel test for the 20% scaled down NREL wind turbine blade)

  • 조태환;김철완;김양원;노주현
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.33.2-33.2
    • /
    • 2011
  • The 'NREL Phase VI' model with a 10.06m diameter was tested in the NASA Ames tunnel to make a reference data of the computational models. The test was conducted at the one rotational speed, blade tip speed 38m/s and the Reynolds number of the sectional airfoils in that test was around 1E6. The 1/5 scale down model of the 'NREL Phase VI' model was used in this paper to study the power characteristics in low Reynolds number region, 0.1E6 ~ 0.4E6 which is achievable range for the conventional wind tunnel facilities. The torque generated by the blade was directly measured by using the torque sensor installed in the rotating axis for a given wind speed and rotational speed. The power characteristics below the stall condition, lambda > 4, was presented in this paper. The power coefficient is very low in the condition below the Re. 0.2E6 and rapidly increases as the Re. increases. And it still increases but the variation is not so big in the condition above the Re. 0.3E6. This results shows that to study the performance of the wind turbine blade by using the scaled down model, the Re. should be larger than the 0.3E6.

  • PDF

Pin Power Reconstruction of HANARO Fuel Assembly via Gamma Scanning and Tomography Method

  • Seo, Chul-Gyo;Park, Chang-Je;Cho, Nam-Zin;Kim, Hark-Rho
    • Nuclear Engineering and Technology
    • /
    • 제33권1호
    • /
    • pp.25-33
    • /
    • 2001
  • To determine the pin power distribution without disassembling, HANARO fuel assemblies are gamma-scanned and then the distribution is reconstructed tv using the tomography method. The iterative least squares method (ILSM and the wavelet singular value decomposition method (WSVD) are chosen to solve the problem. An optimal convergence criterion is used to stop the iteration algorithm to overcome the potential divergence in ILSM. WSVD gives better results than ILSM , and the average values from the two methods give the best results. The RMSE (root mean square errors) to the reference data are 5.1, 6.6, 5.0, 6.5, and 6.4% and the maximum relative errors are 10.2, 13.7, 12.2, 13.6, and 14.3%, respectively. It is found that the effect of random positions of the pins is important. Although the effect can be accommodated by the iterative calculations simulating the random positions, the use of experimental equipment with a slit covering the whole range of the assembly horizontally is recommended to obtain more accurate results. We made a new apparatus using the results of this study and are conducting an experiment in order to obtain more accurate results.

  • PDF

예비 핵연료의 이용 (Utilization of the Stand-by Fuel Assemblies)

  • Kim, Hark-Rho;Chung, Chang-Hyun
    • Nuclear Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.63-72
    • /
    • 1981
  • 핵연료 집합체의 예기치 않은 파손으로 인하여 설계 근거 재장전 방침이 변경되면 원자로심내에서의 출력 분포 비균형을 막기 위하여 파손된 핵연로 집합체 이외에 대칭 위치의 집합체도 제거되어야 할 경우가 있다. 이와 같은 때에 제거된 핵연료 집합체가 설계연소도에 미달되는 경우 이를 다시 사용하여 핵연료 이용률을 증진시키는 것이 연구되었다. TDCORE 코드가 노심ㆍ해석을 위해 이용되었으며, 최적장전모형을 찾는 코드로는 RELOAD-II가 이용되었다. 고리 1호기에 적용한 결과, 제 1주기말에 제거된 비교적 적게 연소된 4개의 핵연료집합체를 제 3주기에서 이용할 경우 주기 연소도가 l1648 MWD/MTU(가동율 : 80%)에 이를 수 있음을 알 수 있었으며 평형주기까지의 장전모형을 추적하였다.

  • PDF