• 제목/요약/키워드: "drop in" Performance test

검색결과 273건 처리시간 0.031초

열가소성 복합재료를 기반한 섬유금속적층판의 충격 거동에 관한 실험 및 수치적 연구 (Numerical and Experimental Investigation on Impact Performance of Fiber Metal Laminates Based on Thermoplastic Composites)

  • 이병언;강동식;박으뜸;김정;강범수;송우진
    • 한국자동차공학회논문집
    • /
    • 제24권5호
    • /
    • pp.566-574
    • /
    • 2016
  • Fiber metal laminates, which are hybrid materials consisting of metal sheets and composite layers, have contributed to aerospace and automotive industries due to their reduced weight and improved damage tolerance characteristics. In this study, the impact performance of the laminates, which are comprised of a self-reinforced polypropylene and two aluminum sheets, and the pure aluminum alloy sheet material were investigated experimentally via numerical simulation. In order to compare the impact performance, the laminates and aluminum alloy were examined by assessing the impact force, energy time histories, and specific energy absorption. ABAQUS is a commercial software that is used to simulate the actual drop-weight tests. Based on this study, it is noted that the impact performance of the laminates was superior to that of the aluminum alloy. In addition, a good agreement between the experimental and numerical results can be achieved when the impact force and energy time histories from the experiments and the numerical simulations are compared.

철도차량 접촉사고자 보호 에어백 개발연구 (Development and Feasible Study of Train to Pedestrian Protection Airbag)

  • 유완동;함정식;조규상
    • 한국자동차공학회논문집
    • /
    • 제20권4호
    • /
    • pp.82-91
    • /
    • 2012
  • This paper deals with the development and feasible study of the train to pedestrian protection airbag. The concept of the airbag system is to protect the pedestrian like as workers on railroad. The airbag system includes cushions, gas generators, a housing, sliding fixture, anti-bouncing airbag, and a leg protection bumper. Those things were designed and fabricated. The performance of the airbag system was evaluated in the sense of the static deployment test, drop test, dynamic motion test and field(train level) test. The deployment logic, TTF(Time to fire), and the inner pressure of the cushion were also investigated for the airbag.

비접착식 콘크리트 덧씌우기 포장에서의 아스팔트와 Geotextile 중간층에 대한 영향 평가 (Evaluation of the Effect of Asphalt and Geotextile Interlayer on Unbonded Concrete Overlay)

  • 조성환;임정혁;황성도
    • 한국도로학회논문집
    • /
    • 제16권2호
    • /
    • pp.91-98
    • /
    • 2014
  • PURPOSES : The objective of this study is to investigate the effect of asphalt and geotextile interlayer on the fracture behavior of unbonded concrete overlay through a laboratory composite beam test. METHODS : In order to evaluate the effect of interlayer materials on the fracture behavior of unbonded concrete overlay, a laboratory test of composite beam was conducted with different types of interlayer. The test results of the composite beam using two types of geotextile interlayer with different thicknesses were compared to the test results of the composite beam using the tradition type of asphalt interlayer. The unbonded concrete overlay on the existing concrete pavement without interlayer was set for the control condition. RESULTS AND CONCLUSION : Overall, the laboratory composite beam test results did show the effect of asphalt and geotextile interlayer on the fracture behavior of composite concrete beams. The three-layer geotextile interlayer and HMA layer both increase the peak load when the first macrocrack occurs in the top concrete beam, while the HMA interlayer causes the smallest load drop percentage after the first macrocrack. The three-layer geotextile did show better performance than the single-layer geotextile through the greater peak load and smaller load drop percentage. It indicates that the thickness of geotextile interlayer will affect the fracture behavior of unbonded concrete overlay and the thicker geotextile interlayer is recommended.

수정된 리버스 식스 테이핑 적용이 편평족의 균형과 보행에 미치는 영향 - 사전연구 (The Effect of Modified Reverse-Six Taping on the Balance and Gait Performance in Pes Planus - Pilot study)

  • 양성화;신영일;이준용
    • 대한정형도수물리치료학회지
    • /
    • 제22권1호
    • /
    • pp.35-41
    • /
    • 2016
  • Background: The purpose of this study was to investigate the effect of modified reverse-six taping on the balance and gait performance in Pes Planus. Methods: A total of twelve subjects (4 males, 8 females) in Pes Planus participated in this study. Navicular drop test was used to evaluate Pes Planus. Balance performance(anterior-posterior; A-P, medial-lateral; M-L), overall) was evaluated using the Biodex balance system in two difference condition(no-taping, with reverse-six taping). Gait performance (cadence, velocity) was evaluated using GAITRite System in two difference condition (no-taping, with reverse-six taping). Results: There were significant improvements of A-P and overall in the balance performance after using reverse-six taping (p<.05). there was no significant improvements of M-L balance performance. and, there were no statistical difference of cadence and velocity in the gait performance after using reverse-six taping. Conclusions: This study found that modified reverse-six taping in Pes Planus was improve the balance performance. but dose not affect the gait performance.

  • PDF

자동차 에어컨 비정상과정 시뮬레이션 (Transient Simulation of an Automotive Air-Conditioning System)

  • 오상한;원성필
    • 설비공학논문집
    • /
    • 제13권11호
    • /
    • pp.1089-1096
    • /
    • 2001
  • The cool-down performance after soaking is very important in an automotive air-conditioning system and is considered as the key design variable. Therefore, understanding of the overall transient characteristics of the system is essential to the preliminary design as well as steady-state characteristics. The objective of this study is to develop a computer simulation model and estimate theoretical1y the transient performance of an automotive air-conditioning system. To accomplish this, a mathematical modelling of each component, such as compressor, condenser, expansion valve, and evaporator, is presented first of all. For a detailed calculation, condenser and evaporator are divided into many subsections. Each sub-section is an elemental volume for modelling. In models of expansion valve and compressor, dynamic behaviors are not considered in an attempt to simplify the ana1ysis, but the quasi-static ones are just considered, such as the relation between mass flow rate and pressure drop in expansion device, polytropic process in compressor, etc. The developed simulation model is validated with a comparison to laboratory test data of an automotive air-conditioning system. The overall time-tracing properties of each component agreed fairly well wish those of test data in this case.

  • PDF

섬유/금속 적층판의 저속 충격 거동 (Impact Behavior of Fiber/Metal Laminates (FMLs) under Low Velocity)

  • 석우;김승현;김병선;송정일
    • Composites Research
    • /
    • 제23권1호
    • /
    • pp.8-16
    • /
    • 2010
  • 섬유금속 적층판(FMLs)은 손상허용도를 향상시키고 무게를 줄이는데 적합하여 항공우주 응용의 신소재로 각광을 받고 있다. 본 연구에서는 우선 섬유와 알루미늄을 이용하여 적층판을 제조하여 인장시험을 수행 후 FMLs의 기계적 물성을 평가하였다. 또한 알루미늄과 섬유적층의 변화를 주어 낙추충격시험기(Drop Weight Impact Tester)를 이용하여 저속충격하에서 낙추 높이를 조절하여 각 종류의 시험편 마다 충격시간에 따른 하중과 충격흡수에너지를 각각 비교하였다. 추가로 유한요소해석을 이용하여 시험조건과 동일 조건하 인장과 충격거동해석을 수행한 결과를 실험치와 비교하여 실험과 이론해석이 잘 일치함을 보였다.

충격기류 탈진방식 여과포집진장치에서 탈진조건 변화에 따른 국산유리섬유여과포의 성능시험 (Performance Test of Domestic Glass Fabric by varying cleaning conditions in a Pulse-Jet Cleaned Fabric Filter)

  • 박영옥;구철오;임정환;김영성;손재익
    • 한국대기환경학회지
    • /
    • 제10권3호
    • /
    • pp.183-190
    • /
    • 1994
  • Performance of domestic glass fabrics was tested in a Pulse- jet cleaned fabric filter under simulated coal combustion. Pulse Pressure were 2.5, 4.0kgf/$\textrm{cm}^2$ and pulse air nozzle diameter were 4.0, 6.0mm Pressure drop and penetration turned out to be low at small pulse air nozzle diameter and low pulse air pressure. Fractional penetration through the dust cake and fabric at face velocity of 1.7m/min was higher than that at face velocity of 1.0m/min. As a consequense, the performance of domestic glass fabrics was better with face velocity of less than 1.0m/min, pulse air pressure of 2.5 kgf/$\textrm{cm}^2$ and pusle air nozzle diameter of 4.0mm.

  • PDF

VHVI 기유의 제품 적용 기술에 관한 연구 - 건설 중장비용 유압유 (A Study On the Application of VHVI Base Oil - Hydraulic Fluid for Construction Equipment)

  • 권완섭;문우식;윤한희;김경웅
    • Tribology and Lubricants
    • /
    • 제20권1호
    • /
    • pp.33-40
    • /
    • 2004
  • This study represents the newly advanced formulation of hydraulic fluids for extended drain interval and introduces the performance results of used oil samples from various excavators. The used oil samples, in this paper, show that there is a sharp change in viscosity drop and moderate additive depletion when viscosity index of hydraulic oil is very high. For the extension of hydraulic fluid life, it is necessary to improve the stability of viscosity and oxidation. New target properties from the used oil analysis were proposed for extended life. Performance of newly developed hydraulic oil based on used oil analysis is compared with previously used one. The properties of new formulation are the viscosity index of 140 and improved thermal stability consists of VHVI base oil. Field test results showed the possibility of extension of fluid life. Additionally, for development of high performance product, new required propertied and performances were discussed.

Contribution of thermal-hydraulic validation tests to the standard design approval of SMART

  • Park, Hyun-Sik;Kwon, Tae-Soon;Moon, Sang-Ki;Cho, Seok;Euh, Dong-Jin;Yi, Sung-Jae
    • Nuclear Engineering and Technology
    • /
    • 제49권7호
    • /
    • pp.1537-1546
    • /
    • 2017
  • Many thermal-hydraulic tests have been conducted at the Korea Atomic Energy Research Institute for verification of the SMART (System-integrated Modular Advanced ReacTor) design, the standard design approval of which was issued by the Korean regulatory body. In this paper, the contributions of these tests to the standard design approval of SMART are discussed. First, an integral effect test facility named VISTA-ITL (Experimental Verification by Integral Simulation of Transients and Accidents-Integral Test Loop) has been utilized to assess the TASS/SMR-S (Transient and Set-point Simulation/Small and Medium) safety analysis code and confirm its conservatism, to support standard design approval, and to construct a database for the SMART design optimization. In addition, many separate effect tests have been performed. The reactor internal flow test has been conducted using the SCOP (SMART COre flow distribution and Pressure drop test) facility to evaluate the reactor internal flow and pressure distributions. An ECC (Emergency Core Coolant) performance test has been carried out using the SWAT (SMART ECC Water Asymmetric Two-phase choking test) facility to evaluate the safety injection performance and to validate the thermal-hydraulic model used in the safety analysis code. The Freon CHF (Critical Heat Flux) test has been performed using the FTHEL (Freon Thermal Hydraulic Experimental Loop) facility to construct a database from the $5{\times}5$ rod bundle Freon CHF tests and to evaluate the DNBR (Departure from Nucleate Boiling Ratio) model in the safety analysis and core design codes. These test results were used for standard design approval of SMART to verify its design bases, design tools, and analysis methodology.

공기극 분극 저항 증가에 따른 SOFC 단전지 성능 감소에 관한 연구 (Performance degradation of SOFC caused by increase of polarization resistance for the cathode during long-term test)

  • 박광진;배중면
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.349-352
    • /
    • 2009
  • In this study, the relation between the performance degradation of SOFC single cell and the increase of polarization resistance for the cathode is investigated. $Pr_{0.3}Sr_{0.7}Co_{0.3}Fe_{0.7}O_3$(PSCF3737, $19.4{\times}10^{-6}K^{-1}$) and $Gd_{0.1}Ce_{0.9}O_2$ (CGO91, $12{\times}10^{-6}K^{-1}$) are used as a cathode and an electrolyte, respectively. The polarization resistance of cathode is increased due to the delamination caused by thermal expansion coefficient difference. The voltage drop with 10%/1000h decline rate occurs during long-term, when the interface between the cathode and the electrolyte is delaminated due to TEC difference.

  • PDF