Abstract
In this study, Seochon Thermal Power Plant No.1 for anthracite coal was tested to find the proper operation range of limestone slurry pH in the absorber tower which can be operated continuously in compliance with the Air Quality Preservation Act and Seocheon Thermal Power Division's internal regulation, sulfur dioxide average emission regulation. When operating the sulfur dioxide concentration [ppm] in the combustion gas flowing into the desulfurization absorption tower at 370, 400, 460 and 550 ppm while the main operating elements such as the flow rate of the combustion gas were fixed, the proper slurry pH Were 4.4, 4.5, 4.8 and 5.1, respectively. Therefore, it is recommended to operate with the correlation equation, RpH=0.004×Cin+2.93 derived using sulfur dioxide and the appropriate slurry pH.
Keywords
Flue Gas Desulfurizer, FGD; Absorber; Limestone Slurry pH; SO2 Concentration;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Adam Sieminski, 2017, Renewables grow fastest, coal use plateaus, natural gas surpasses coal by 2030, and oil maintains its leading share, Inter-national Energy Outlook 2018, U.S. Energy Information Administration, pp. 7.
2 Seung-su Park, Jin-pyo Hong, Sang-yong Park, Ki-hyung Kim, 1988, Exhaust gas desulfurization using a gas-phase porous plate absorber, Journal of Korean Society of Atmospheric and Environmental Engineering, Vol.20 No.11, 1611-1618.
3 Minister of Environment, 2017, Enforcement Re-gulations of the Air Quality Preservation Act, A-rticle 15, Law 16, Paragraph 1, Annex 8.
4 Korea KOMIPO Environmental Chemistry Team, 2015, Operation target notification for efficiency. operation of desulfurization absorption tower No. 1 and No. 2, Seocheon 52101-1987, KOMIPO co., Ltd.
5 Korea Power Learning Institute, 2015, Practice of Desulfurization Facility, Korea Power Learning Institute, Revision 3, pp. 146-147.
6 Recommendation on the slurry pH for proper operation of desulfurization absorber in a 200MW power plant, Dept. of master's degree, No. 107. pp. 18