1 |
C.G. Lin, Z.S. Yu, Passive Safety Advanced Pressurized Water Reactor Technology, Atomic Energy Press, Beijing, 2008.
|
2 |
H.H. Sun, P.D. Cheng, H.X. Miu, W.Z. Zhang, X.G. Zhu, M.H. Weng, Third Generation Nuclear Power Technology AP1000, China Electric Power Press, Beijing, 2010.
|
3 |
L.L.C. Westinghouse, Westinghouse AP1000 Design Control Document, Westinghouse Electric Company LLC, Pittsburgh (PA), 2012.
|
4 |
C. Xing, Y. Zhang, Z. Zheng, Control and monitoring of AP1000 constant axial offset, East China Electr. Power 2 (2013) 0420-0423.
|
5 |
R. Wang, Y. Zhou, Correction of ex-core nuclear instrumentation measurement in mechanical shim mode, Electr. Instrum. Customers 5 (2013) 93-95.
|
6 |
Z.Y. Xiao, Z.S. Yang, Inverse function amplifier for selfpowered detectors, Nucl. Power Eng. 5 (1982) 30-35.
|
7 |
Z. Xu, Design of axial offset control with compensated vanadium detectors, At. Energy Sci. Technol. 50 (2016) 524-530.
|
8 |
J.L. Pu, Guangdong Daya Bay Nuclear Power Plant Running Tutorial, Atomic Energy Press, Beijing, 1999.
|
9 |
National Nuclear Data Center [Internet]. Information extracted from the NuDat 2 database. Available from: http://www.nndc.bnl.gov/nudat2/. (Accessed 15 August).
|
10 |
W.Z. Liu, S.C. Li, Z.X. Hu, Z.M. Tang, Q. Yang, The introduction of self-powered detector and study for its escape probability calculation algorithm for b particle, Nucl. Electron. Detect. Technol. 1 (2015) 5-7.
|
11 |
H. Weiss, Experimental Comparison between In-core Gamma Radiation and Neutron Flux Density Distribution in a Pressurized Water Reactor, Westinghouse Electric Corporation, Pittsburgh (PA), 1970.
|
12 |
J.J. Loving, Neutron, temperature, and gamma sensors for pressurized water reactors, IEEE Trans. Ind. Electron. Control Instrum IECI-17 (1970) 120-129.
DOI
|
13 |
Y.N. Yang, W.Z. Wang, J.H. Sun, D.J. Zhou, Flexible vanadium self-powered detectors, Nucl. Electron. Detect. Technol. 2 (1983) 21-28.
|
14 |
O. Strindehag, Self-powered Neutron and Gamma Detectors for In-core Measurements, Ab. Atomenergi, [Rapp.] AE AE-440, 1971, pp. 1-18.
|
15 |
Y.M. Yu, Properties of long vanadium self-powered detector, Nucl. Tech. 1 (1980) 15-19, 27.
|
16 |
K.M. Li, The application of self-powered detectors in intensive g core, Nucl. Sci. Eng. 3 (1983) 359-365.
|
17 |
M.L. Kantrowitz, An improved dynamic compensation algorithm for rhodium self-powered neutron detectors, IEEE Trans. Nucl. Sci. 34 (1987) 562-566.
DOI
|
18 |
M.G. Park, Y.H. Kim, K.H. Cha, M.K. Kim, filtering for dynamic compensation of self-powered neutron detectors-a linear matrix inequality based method, Ann. Nucl. Energy 26 (1999) 1669-1682.
DOI
|
19 |
S.C. Li, L.T. Xiao, Research of delayed response elimination algorithm for rhodium self-powered detectors, Nucl. Electron. Detect. Technol. 29 (2009) 1516-1519.
|
20 |
X.J. Peng, Q. Li, W.B. Zhao, H.L. Gong, K. Wang, Robust filtering for dynamic compensation of self-powered neutron detectors, Nucl. Eng. Des. 280 (2014) 122-129.
DOI
|
21 |
X.J. Peng, Q. Li, K. Wang, Dynamic compensation of vanadium self-powered neutron detectors based on Luenberger form filter, Prog. Nucl. Energy 78 (2015) 190-195.
DOI
|
22 |
Z. Xu, Q. Bao, Analysis on the response time testing of protection for PWR, Nucl. Tech. 38 (2015) 040606-1-040606-7.
|
23 |
O. Moreira, H. Lescano, Analysis of vanadium self-powered neutron detector's signal, Ann. Nucl. Energy 58 (2013) 90-94.
DOI
|
24 |
H.T. William, Characteristics of self-powered neutron detectors used in power reactors, Proceedings of a Specialists' Meeting, Mito-shi, Japan, 14-17 October,1996. Session 4: Instrumentation. pp. 1-10. https://www.oecd-nea.org/science/rsd/ic96/4-2.pdf.
|
25 |
P.S. Rao, S.C. Misra, Neutron sensitivity of vanadium self-powered neutron detectors, Nucl. Instr. Meth. Phys. Res. A 253 (1986) 57-60.
DOI
|