Browse > Article
http://dx.doi.org/10.12989/scs.2018.27.1.095

Eccentrically compressive behaviour of RC square short columns reinforced with a new composite method  

Zhang, Fan (School of Resources and Civil Engineering, Northeastern University)
Lu, Yiyan (School of Civil Engineering, Wuhan University)
Li, Shan (School of Civil Engineering, Wuhan University)
Zhang, Wenlong (School of Civil Engineering, Wuhan University)
Publication Information
Steel and Composite Structures / v.27, no.1, 2018 , pp. 95-108 More about this Journal
Abstract
A new composite reinforced method, namely self-compacting concrete filled circular CFRP-steel jacketing, was proposed in this paper. Experimental tests on eight RC square short columns reinforced with the new composite reinforced method and four RC square short columns reinforced with CFS jackets were conducted to investigate their eccentrically compressive behaviour. Nine reinforced columns were subjected to eccentrically compressive loading, while three reinforced columns were subjected to axial compressive loading as reference. The parameters investigated herein were the eccentricity of the compressive loading and the layer of CFRP. Subsequently, the failure mode, ultimate load, deformation and strain of these reinforced columns were discussed. Their failure modes included the excessive bending deformation, serious buckling of steel jackets, crush of concrete and fracture of CFRP. Moreover, these reinforced columns exhibited a ductile failure globally. Both the eccentricity of the compressive loading and the layer of CFRP had a significant effect on the eccentrically compressive behaviour of reinforced columns. Finally, formulae for the evaluation of the ultimate load of reinforced columns were proposed. The theoretical formulae based on the ultimate equilibrium theory provided an effective, acceptable and safe method for designers to calculate the ultimate load of reinforced columns under eccentrically compressive loading.
Keywords
new composite reinforced method; eccentrically compressive behaviour; experimental tests; theoretical formulae;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Vandoros, K G. and Dritsos, S.E. (2008), "Concrete jacket construction detail effectiveness when strengthening RC columns", Constr. Build. Mater., 22(3), 264-276.   DOI
2 Wang, Y.F., Ma, Y.S. and Wu, H.L. (2011), "Reinforced highstrength concrete square columns confined by aramid FRP jackets. Part I: Experimental Study", Steel Compos. Struct., Int. J., 11(6), 455-468.   DOI
3 Wang, D., Wang, Z., Smith, S.T. and Yu, T. (2017), "Seismic performance of CFRP-confined circular high-strength concrete columns with high axial compression ratio", Constr. Build. Mater., 134, 91-103.   DOI
4 Wu, H.L., Wang, Y. F. and Ma, Y.S. (2011), "Reinforced highstrength concrete square columns confined by aramid FRP jackets. Part II: Modeling", Steel Compos. Struct., Int. J., 11(4), 325-340.
5 Shin, J., Scott, D.W., Stewart, L.K., Yang, C.S., Wright, T.R. and DesRoches, R. (2016), "Dynamic response of a full-scale reinforced concrete building frame retrofitted with FRP column jackets", Eng. Struct., 125, 244-253.   DOI
6 Achillopoulou, D.V., Kiziridou, A.N., Papachatzakis, G.A. and Karabinis, A.I. (2016), "Investigation of interface response of reinforced concrete columns retrofitted with composites", Steel Compos. Struct., Int. J., 22(6), 1337-1358.   DOI
7 Cai, S.H. (2003). Modern steel tube confined concrete structures, China Communications Press, Beijing, China.
8 Dubey, R. and Kumar, P. (2016), "Experimental study of the effectiveness of retrofitting RC cylindrical columns using selfcompacting concrete jackets", Constr. Build. Mater., 124, 104-117.   DOI
9 Elbakry, H.M.F. and Tarabia, A.M. (2016), "Factors affecting bond strength of RC column jackets", Alexandria Eng. J., 55(1), 57-67.   DOI
10 GB/T 228-2002 (2002), Metallic materials-tensile testing at ambient temperature; General administration of quality supervision, inspection and quarantine of the people's republic of China. [In Chinese]
11 Huang, Y.J., Xiao, J.Z. and Shen, L. (2016), "Damage assessment for seismic response of recycled concrete filled steel tube columns", Earthq. Eng. Eng. Vib., 15(3), 607-616.   DOI
12 Jiang, S., Guo, X., Xiong, Z., Cai, Y. and Zhu, S. (2017), "Experimental studies on behaviour of tubular T-joints reinforced with grouted sleeve", Steel Compos. Struct., Int. J., 23(5), 585-596.   DOI
13 Juntanalikit, P., Jirawattanasomkul, T. and Pimanmas, A. (2016), "Experimental and numerical study of strengthening non-ductile RC columns with and without lap splice by Carbon Fiber Reinforced Polymer (CFRP) jacketing", Eng. Struct., 125, 400-418.   DOI
14 Minafo, G. (2015), "A practical approach for the strength evaluation of RC columns reinforced with RC jackets", Eng. Struct., 85, 162-169.   DOI
15 Minafo, G. and Papia, M. (2016), "Concrete softening effects on the axial capacity of RC jacketed circular columns", Eng. Struct., 128, 215-224.   DOI
16 Minafo, G., Trapani, F.D. and Amato, G. (2016), "Strength and ductility of RC jacketed columns: A simplified analytical method", Eng. Struct., 122, 184-195.   DOI
17 Quiertant, M. and Clement, J.L. (2011), "Behavior of RC columns strengthened with different CFRP systems under eccentric loading", Constr. Build. Mater., 25(2), 452-460.   DOI
18 Rahai, A. and Akbarpour, H. (2014), "Experimental investigation on rectangular RC columns strengthened with CFRP composites under axial load and biaxial bending", Compos. Struct., 108, 538-546.   DOI
19 Sezen, H. and Miller, E.A. (2011), "Experimental evaluation of axial behavior of strengthened circular reinforced-concrete columns", J. Bridge Eng., ASCE, 16(2), 238-247.   DOI
20 GB/T 3354-1999 (1999), Test method for tensile properties of orientation fiber reinforced polymer matrix composite materials; General administration of quality supervision, inspection and quarantine of the people's republic of China, Standardization administration of the people's republic of China. [In Chinese]
21 GB 50010-2015 (2015), Code for design of concrete structures, General administration of quality supervision, inspection and quarantine of the people's republic of China, Standardization administration of the people's republic of China. [In Chinese]
22 GB/T 50081-2002 (2002), Standard for test mehtod of mechanical properties on ordinary concrete, Ministry of housing and urbanrural development of the people's republic of China, General administration of quality supervision, inspection and quarantine of the people's republic of China. [In Chinese]
23 GB 50936-2014 (2014), Technical code for concrete filled steel tubular structures, Ministry of housing and urban-rural development of the people's republic of China, General administration of quality supervision, inspection and quarantine of the people's republic of China. [In Chinese]
24 Gu, W., Li, H.N. and Zhang, N.M. (2011), "Constitutive relation of concrete of concrete-filled CFRP-steel tubular short columns with axial compression", J. Dalian Univ. Technol., 51(4), 545-548. [In Chinese]
25 He, A., Cai, J., Chen, Q.J., Liu, X. and Xu, J. (2016), "Behaviour of steel-jacket retrofitted RC columns with preload effects", Thin-Wall. Struct., 109, 25-39.   DOI
26 He, A., Cai, J., Chen, Q.J., Liu, X., Xue, H. and Yu, C. (2017), "Axial compressive behaviour of steel-jacket retrofitted RC columns with recycled aggregate concrete", Constr. Build. Mater., 141, 501-516.   DOI
27 Hua, W., Wang, H.J. and Hasegawa, A. (2014), "Experimental study on reinforced concrete filled circular steel tubular columns", Steel Compos. Struct., Int. J., 17(4), 517-553.   DOI