Browse > Article
http://dx.doi.org/10.12989/cac.2017.20.2.177

Strength degeneracy of LWAC and flexural behavior of LWAC members after fire  

Tang, Chao-Wei (Department Civil Engineering & Geomatics, Cheng Shiu University)
Publication Information
Computers and Concrete / v.20, no.2, 2017 , pp. 177-184 More about this Journal
Abstract
The characteristics of lightweight aggregate (LWA) with a low specific gravity and high water absorption will significantly change the properties of lightweight aggregate concrete (LWAC). This study aimed at exploring the effect of presoaking degree of LWA on the strength degeneracy of LWAC and flexural behavior of LWAC members exposed to elevated temperatures. The residual mechanical properties of the LWAC subjected to elevated temperatures were first conducted. Then, the residual load tests of LWAC members (beams and slabs) after exposure to elevated temperatures were carried out. The test results showed that with increasing temperature, the decreasing trend of elastic modulus for LWAC was considerably more serious than the compressive strength. Besides, the presoaking degree of LWA had a significant influence on the residual compressive strength and elastic modulus for LWAC after exposure to $800^{\circ}C$. Moreover, owing to different types of heating, the residual load bearing capacity of the slab specimens were significantly different from those of the beam specimens.
Keywords
lightweight aggregate; reinforced concrete members; fire damage;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Lo, Y., Cui, H.Z. and Li, Z.G. (2004), "Influence of aggregate prewetting and fly ash on mechanical properties of lightweight concrete", J. Waste Manage., 24(4), 333-338.   DOI
2 Lo, Y., Cui, H.Z., Tang, W.C. and Leung, W.M. (2008), "The effect of aggregate absorption on pore area at interfacial zone of lightweight concrete", Constr. Build. Mater., 22(4), 623-628.   DOI
3 Oktay, H., Yumrutas, R. and Akpolat, A. (2015), "Mechanical and thermophysical properties of lightweight aggregate concretes", Constr. Build. Mater., 96, 217-225.   DOI
4 Siddique, R. and Kaur, D. (2012), "Properties of concrete containing ground granulated blast furnace slag (GGBFS) at elevated temperatures", J. Adv. Res., 3(1), 45-51.   DOI
5 Somayaji, S. (2001), Civil Engineering Materials, Prentice Hall, Upper Siddle River, New Jersey, U.S.A.
6 Tang, C.W., Chen, H.J., Wang, S.Y. and Spaulding, J. (2011), "Production of synthetic lightweight aggregate using reservoir sediments for concrete and masonry", Cement Concrete Comp., 33(2), 292-300.   DOI
7 Tang, C.W. (2014), "Producing synthetic lightweight aggregates by treating waste TFT-LCD glass powder and reservoir sediments", Comput. Concrete, 13(2), 149-171.   DOI
8 Vakhshouri, B. and Nejadi, S. (2016), "Self-compacting lightweight concrete; mix design and proportions", Struct. Eng. Mech., 58(1), 143-161.   DOI
9 Wu, X., Wu, Z.M., Zheng, J.J., Ueda, T. and Yi, S.H. (2013), "An experimental study on the performance of self-compacting lightweight concrete exposed to elevated temperature", Mag. Concrete Res., 65(13), 780-786.   DOI
10 Young, J.F., Mindess, S. and Daewin, D. (2002), Concrete, Prentice-Hall, Inc., Upper Saddle River, New Jersey, U.S.A.
11 BE96-3942/R20 (2000), The Effect of the Moisture History on the Water Absorption of Lightweight Aggregates, EuroLightCon.
12 Yu, K., Yu, J., Lu, Z. and Chen, Q. (2016), "Fracture properties of high-strength/high-performance concrete (HSC/HPC) exposed to high temperature", Mater. Struct., 49(11), 4517-4532.   DOI
13 Zhang, J., Wang, J. and Han Y. (2015), "Simulation of moisture field of concrete with pre-soaked lightweight aggregate addition", Constr. Build. Mater., 96, 599-614.   DOI
14 ACI 318-14 (2014), Building Code Requirements for Structural Concrete and Commentary, American Concrete Institute.
15 ASTM C39/C39M-14a (2014), Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens, ASTM International, West Conshohocken, Pennsylvania, U.S.A.
16 ASTM C469/C469M-14 (2014), Standard Test Method for Static Modulus of Elasticity and Poisson's Ratio of Concrete in Compression, ASTM International, West Conshohocken, Pennsylvania, U.S.A.
17 ASTM C496-96 (1996), Standard Test Method for Splitting Tensile Strength of Cylindrical Concrete Specimens, ASTM International, West Conshohocken, Pennsylvania, U.S.A.
18 ASTM C78/C78M-10 (2010), Standard Test Method for Flexural Strength of Concrete (Using Simple Beam with Third-Point Loading), ASTM International, West Conshohocken, Pennsylvania, U.S.A.
19 Chandra, S. and Berntsson, L. (2002), Lightweight Aggregate Concrete, Noyes Publications, New York, U.S.A.
20 CNS 7332 (2007), Method of Determination for Thermal Conductivity of Heat Insulating Materials by Means of Comparison with a Standard Plate of Known Conductivity, Bureau of Standards, Metrology and Inspection, M.O.E.A., R.O.C..
21 Copier, W.J. (1983), "The spalling of normal weight and lightweight concrete exposed to fire", J. Am. Concrete Inst., 80(4), 352-353.
22 Dong, Z. and Keru, W. (2001), "Fracture properties of highstrength concrete", J. Mater. Civil Eng., 13(1), 86-88.   DOI
23 Galle, C. (2001), "Effect of drying on cement-based materials pore structure as identified by mercury intrusion porosimetry-a comparative study between oven-, vacuum-, and freeze-drying", Cement Concrete Res., 31(10), 1467-1477.   DOI
24 GB/T2842-81 (1981), Test Method for Lightweight Aggregates, China National Standard.
25 Hsu, T.T.C., Slate, F.O., Sturman, G.M. and Winter, G. (1963), "Microcracking of plain concrete and the shape of the stressstrain curve", ACI Mater. J., 60(2), 209-224.
26 Hammer, T.A. (1990), Marine Concrete Structures Exposed to Hydrocarbon Fire-Spalling Resistance of LWA Concrete, SINTEF-Report No. STF65 A88064, Trondheim, 8.
27 Hansen, P.A. and Jensen, J.J. (1995), Fire Resistance and Spalling Behavior of LWA Beams, Report 6.3, High Strength Concrete phase 3, SINTEF-Report No. STF70 A95004, Trondheim, 13.
28 He, K.C., Guo, R.X., Ma, Q.M., Yan, F., Lin, Z.W. and Sun, Y.L. (2016), "Experimental research on high temperature resistance of modified lightweight concrete after exposure to elevated temperatures", Adv. Mater. Sci. Eng., 6.
29 Holm, T.A. (1994), Lightweight Concrete and Aggregates, Standard Technical Publication 196C.
30 Holm, T.A., Ooi, O.S. and Bremner, T.W. (2004), Moisture Dynamics in Lightweight Aggregate and Concrete, Expanded Shale Clay & Slate Institute.
31 Hwang, C.L. and Tran, V.A. (2015), "A study of the properties of foamed lightweight aggregate for self-consolidating concrete", Constr. Build. Mater., 87, 78-85.   DOI
32 Ji, T., Zheng, D.D., Chen, X.F., Lin, X.J. and Wu, H.C. (2015), "Effect of prewetting degree of ceramsite on the early-age autogenous shrinkage of lightweight aggregate concrete", Constr. Build. Mater., 98, 102-111.   DOI
33 Lo, Y., Gao, X.F. and Jeary, A.P. (1999), "Microstructure of prewetted aggregate on lightweight concrete", Build. Environ., 34(6), 759-764.   DOI
34 Karatas, M., Balun, B. and Benli, A. (2017), "High temperature resistance of self-compacting lightweight mortar incorporating expanded perlite and pumice", Comput. Concrete, 19(2), 121-126.   DOI
35 Liu, X. and Zhang, M.H. (2010), "Permeability of highperformance concrete incorporating presoaked lightweight aggregates for internal curing", Mag. Concrete Res., 62(2), 79-89.   DOI