ASSESSMENT OF MARS FOR DIRECT CONTACT CONDENSATION IN THE CORE MAKE-UP TANK  

Park, Keun Tae (Korea Atomic Energy Research Institute, Thermal Hydraulics Safety Research Division)
Park, Ik Kyu (Korea Atomic Energy Research Institute, Thermal Hydraulics Safety Research Division)
Lee, Seung Wook (Korea Atomic Energy Research Institute, Thermal Hydraulics Safety Research Division)
Park, Hyun Sik (Korea Atomic Energy Research Institute, Thermal Hydraulics Safety Research Division)
Publication Information
Journal of computational fluids engineering / v.19, no.1, 2014 , pp. 64-72 More about this Journal
Abstract
This study aimed at assessing the analysis capability of thermal-hydraulic computer code, MARS for the behaviors of the core make-up tank (CMT). The sensitivity study on the nodalization to simulate the CMT was conducted, and the MARS calculations were compared with KAIST experimental data and RELAP5/MOD3.3 calculations. The 12-node model was fixed through a nodalization study to investigate the effect of the number of nodes in the CMT (2-, 4-, 8-, 12-, 16-node). The sensitivity studies on various parameters, such as water subcooling of the CMT, steam pressure, and natural circulation flow were done. MARS calculations were reasonable in the injection time and the effects of several parameters on the CMT behaviors even though the mesh-dependency should be properly treated for reactor applications.
Keywords
MARS; Core Make-up Tank; Direct Contact Condensation; Thermal Stratification; Passive Safety Injection System;
Citations & Related Records
연도 인용수 순위
  • Reference
1 1998, Tower, S.N., Schulz, T.L. and Vijuk, R.P., "Passive and simplified system features for the advanced westinghouse 600 MWe PWR," Nucl. Eng. Des., Vol.109, pp.147-154.
2 2006, Schulz, T.L., "Westinghouse AP1000 advanced passive plant," Nucl. Eng. Des., Vol.236, pp.1547-1557.   DOI
3 1997, Chang, S.H., No, H.C., Baek, W.P., Lee, S.I. and Lee, S.W., "Conceptual desing of CARR passive PWR 1300MWe (CP1300)," Nucl. Eng. Int.
4 2013, Chang, S.H., Kim, S.H. and Choi, J.Y., "Design of integrated passive safety system (IPSS) for ultimate passive safety of nuclear power plants," Nucl. Eng. Des., Vol.260, pp.104-120.   DOI   ScienceOn
5 1999, Tuunanen, J., Vihavainen, J., D'Auria, F. and Kimber, G., "Assessment of passive safety injection systems of ALWRs," Final report of the European Commission 4th Framework Programme Project FI4I-CT95-0004, Technical Research Centre of Finland.
6 2000, IAEA, "Natural circulation data and methods for advanced water cooled nuclear power plant designs," Proceedings of a Technical Committee meeting, Vienna, Austria.
7 2013, Wang, M., Tian, W., Qiu, S., Su, G. and Zhang, Y., "An evaluation of designed passive Core Makeup Tank (CMT) for China pressurized reactor (CPR1000)," Ann. Nucl. Energy, Vol.56, pp.81-86.   DOI
8 2006, Yonomoto, T. and Sibamoto, Y., "Summary on natural circulation phenomena observed in ROSA/AP600 tests," IAEA's Third Research Coordination Meeting, CEA, Cadarache, France.
9 1998, Lee, S.I. and No, H.C., "Gravity-driven injection experiments and direct-contact condensation regime map for passive high-pressure injection system," Nucl. Eng. Des., Vol.183, pp.213-234.   DOI
10 1997, Lee, S.I. and No, H.C., "Assessment of RELAP5/MOD3.1 for direct-contact condensation in the core makeup tank of the CARR passive reactor," Ann. Nucl. Energy, Vol.24, pp.445-562.
11 2001, Nuclear Safety Analysis Division, RELAP5 /MOD3.3 Code Manual Vol. I: Code structure, system models, and solution methods, Idaho National Engineering and Environmental Laboratory, USA.
12 1998, Lee, S.I. and No, H.C., "Improvement of direct contact condensation model of RELAP5/MOD3.1 for passive high-pressure injection system," Ann. Nucl. Energy, Vol.25, pp.677-688.   DOI
13 2004, Thermal Hydraulic Safety Research Department, MARS code manual Vol. I: Code structure, system models, and solution methods, Korea Atomic Energy Research Institute.
14 1996, Wright, R.F., Hundal, R., Hochreiter, L.E., Friend M.T. and Ogrins, M., "Analysis and evaluation of the AP600 SPES-2 integral system tests," Proceedings of the 4th International Conference on Nuclear Engineering, NewOrleans, USA.
15 2013, Park, I.K., Lee, J.R., Lee, S.W., Yoon, H.Y. and Jeong, J.J., "An implicit code coupling of 1-D system code and 3-D in-house CFD code for multi-scaled simulations of nuclear reactor transients," Ann. Nucl. Energy, Vol.59, pp.80-91.   DOI   ScienceOn
16 2013, Chun, J.H., Lee, G.H., Bae, Y.J., Chung, Y.J. and Kim, K.K., "Performance Evaluation of SMART Passive Safety System for SBLOCA Using MARS Code," Transactions of Korean Nuclear Society Spring Meeting, Gwangju, Korea.