Abstract
Nonlinear static analysis and preliminary evaluation were performed in this study to evaluate the seismic performance of unreinforced masonry buildings subjected to various soil conditions based on the revised Korean Building Code. Preliminary evaluation scores and nonlinear static analyses indicated that all buildings were susceptible to collapse and did not reach their target performance. Therefore, retrofit of those building models was carried out through a systematic procedure to determine areas to be strengthened. It was possible to make most building models satisfy performance objectives through the reinforcement alone of damaged external shear walls. However, the application of a preliminary evaluation procedure to retrofit design was found to be too conservative because all the retrofitted building models verified with nonlinear static analysis failed to satisfy performance objectives. Therefore, it is possible to economically retrofit unreinforced masonry buildings through the fortification of external walls if a simple evaluation procedure that can efficiently specify vulnerable parts is developed.
Keywords
Seismic performance evaluation; Nonlinear static analysis; Seismic retrofit; Unreinforced masonry buildings;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Kim TW, Min CG, Lee HM. Seismic Performance Evaluation of Unreinforced Masonry Buildings By Using a Three-Step Procedure. EESK J. Earthquake Eng. 2011 Jun;15(3):57-64.
2 Yi WH, Lee JH, Oh SH, Yang WJ, Kang DE. A Study on Evaluation of Shear Capacity of Unreinforced Masonry Wall. Journal of the Architectural Institute of Korea. 2005 Oct;21(10):3-10.
3 Baek EL, Kim JH, Lee SH, Oh SH. Nonlinear Analysis mod el Considering Failure Mode of Unreinforced Masonry Wall. Journal of the Korea Institute for Structural Maintenance and Inspection. 2014 Jul;18(4):33-40.   DOI
4 Heo JS, Lee SH. Analytical Study on the Seismic Capacity for Existing Masonry Building in Korea. Journal of the Korea Institute for Structural Maintenance and Inspection. 2009 Nov;13(6):75-87.
5 Hong JM, SHin DH, Kim HJ. Nonlinear Analytical Model of Unreinforced Masonry Wall using Fiber and Shear Spring Elements. Journal of Computational Structural Engineering Institute in Korea. 2018 Dec;31(6):283-291.   DOI
6 Parisi F, Augenti N. Seismic Capacity of Irregular UnReinforced Masonry Walls with Openings. Journal of the Earthquake Engineering Structural Dynamics. 2013 Jan;42(1):101-121.   DOI
7 Nakamura Y, Derakhshan H, Rfiffith MC, Magenes G, Sheikh AH. Applicability of Nonlinear Static Procedures for Low-rise Unreinforced Masonry Buildings with Flexible DiaPhragms. Journal of Engineering Structures. 2017 Apr;137:1-18.   DOI
8 American Society of Civil Engineers. ASCE 41-17 Seismic Evaluation and Retrofit of Existing Buildings. c2017.
9 National Disaster management Research institute. Study on Seismic Retrofitting Techniques for Unreinforced Masonry Buildings. c2009.
10 Architectural Institute of Korea. Seismic Building Design Code and Commentary(Korea Building Code). c2019.
11 Korea Infrastructure Safety Corporation. Guide Lines for Seismic Performance Evaluation for Existing Buildings. c2013.
12 Ministry of Education. Seismic performance evaluation and retrofit manual for school facilities. c2019.
13 Choi HK, Park BK, Bae BI, Choi CS. Lateral Resistance of Unreinforced Masonry Walls Retrofitted with ECC. Journal of the Architectural Institute of Korea Structure & Construction. 2010 Dec;26(12):3-10.