Browse > Article
http://dx.doi.org/10.3904/kjim.2014.210

Comparison of enhancement and image quality: different iodine concentrations for liver on 128-slice multidetector computed tomography in the same chronic liver disease patients  

Jo, Byoung Goo (Department of Radiology, Samsung Changwon Hospital, Sungkyunkwan University School of Medicine)
Song, Yun Gyu (Department of Radiology, Samsung Changwon Hospital, Sungkyunkwan University School of Medicine)
Shim, Sang Goon (Department of Internal Medicine, Samsung Changwon Hospital, Sungkyunkwan University School of Medicine)
Kim, Young Wook (Department of Occupational and Environmental Medicine, Samsung Changwon Hospital, Sungkyunkwan University School of Medicine)
Publication Information
The Korean journal of internal medicine / v.31, no.3, 2016 , pp. 461-469 More about this Journal
Abstract
Background/Aims: The objective of this study was to compare the degree of hepatic enhancement and image quality using contrast media of different iodine concentrations with the same iodine dose. Methods: From July 2011 to June 2013, 50 patients with chronic liver disease who underwent baseline and follow-up 128-slice multidetector computed tomography (MDCT) using contrast media with 350 mg I/mL (group A) and 400 mg I/mL (group B) iodine concentrations were included in this prospective study. The patients were randomly allocated to one of two protocols: 350 mg I/mL initially and then 400 mg I/mL; and 400 mg I/mL initially and then 350 mg I/mL. The bolus tracking technique was used to initiate the arterial phase scan. The computed tomography values of hepatic parenchyma, abdominal aorta and portal vein were measured. The degrees of hepatic and vascular enhancement were rated on a 4-point scale for qualitative assessment. The paired Student t test was used to compare outcome variables. Results: The mean hepatic enhancement was significantly higher in group B than in group A during the portal (p = 0.025) and equilibrium phases (p = 0.021). In all phases, group B had significantly higher mean liver-to-aorta contrast (p < 0.05) and mean visual scores for hepatic and vascular enhancement (p < 0.001). Conclusions: This study showed that a higher iodine concentration (400 mg I/mL) in contrast media was more effective at improving hepatic enhancement in portal and equilibrium phase images and overall image quality using 128-slice MDCT in chronic liver disease patients.
Keywords
Multidetector computed tomography; Liver; Contrast media; Iodine;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Tozaki M, Naruo K, Fukuda K. Dynamic contrast-enhanced MDCT of the liver: analysis of the effect of different iodine concentrations with the same total iodine dose in the same chronic liver disease patients. Radiat Med 2005;23:533-538.
2 Cademartiri F, de Monye C, Pugliese F, et al. High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography: iopromide 370 versus iomeprol 400. Invest Radiol 2006;41:349-353.   DOI
3 Setty BN, Sahani DV, Ouellette-Piazzo K, Hahn PF, Shepard JA. Comparison of enhancement, image quality, cost, and adverse reactions using 2 different contrast medium concentrations for routine chest CT on 16-slice MDCT. J Comput Assist Tomogr 2006;30:818-822.   DOI
4 Sultana S, Morishita S, Awai K, et al. Evaluation of hypervascular hepatocellular carcinoma in cirrhotic liver by means of helical CT: comparison of different contrast medium concentrations within the same patient. Radiat Med 2003;21:239-245.
5 Tsurusaki M, Sugimoto K, Fujii M, Sugimura K. Multi- detector row helical CT of the liver: quantitative assessment of iodine concentration of intravenous contrast material on multiphasic CT: a prospective randomized study. Radiat Med 2004;22:239-245.
6 Bonaldi VM, Bret PM, Reinhold C, Atri M. Helical CT of the liver: value of an early hepatic arterial phase. Radiology 1995;197:357-363.   DOI
7 Ito K, Honjo K, Fujita T, et al. Liver neoplasms: diagnostic pitfalls in cross-sectional imaging. Radiographics 1996;16:273-293.   DOI
8 Takayasu K, Furukawa H, Wakao F, et al. CT diagnosis of early hepatocellular carcinoma: sensitivity, findings, and CT-pathologic correlation. AJR Am J Roentgenol 1995;164:885-890.   DOI
9 Cademartiri F, Mollet NR, van der Lugt A, et al. Intravenous contrast material administration at helical 16-detector row CT coronary angiography: effect of iodine concentration on vascular attenuation. Radiology 2005;236:661-665.   DOI
10 Yanaga Y, Awai K, Nakayama Y, et al. Optimal dose and injection duration (injection rate) of contrast material for depiction of hypervascular hepatocellular carcinomas by multidetector CT. Radiat Med 2007;25:278-288.   DOI
11 Sahani DV, Soulez G, Chen KM, et al. A comparison of the efficacy and safety of iopamidol-370 and iodixanol-320 in patients undergoing multidetector-row computed tomography. Invest Radiol 2007;42:856-861.   DOI
12 Romano L, Grazioli L, Bonomo L, et al. Enhancement and safety of iomeprol-400 and iodixanol-320 in patients undergoing abdominal multidetector CT. Br J Radiol 2009;82:204-211.   DOI
13 Yagyu Y, Awai K, Inoue M, et al. MDCT of hypervascular hepatocellular carcinomas: a prospective study using contrast materials with different iodine concentrations. AJR Am J Roentgenol 2005;184:1535-1540.   DOI
14 Fleischmann D. Use of high concentration contrast media: principles and rationale-vascular district. Eur J Radiol 2003;45 Suppl 1:S88-S93.   DOI
15 Fleischmann D. High-concentration contrast media in MDCT angiography: principles and rationale. Eur Radiol 2003;13 Suppl 3:N39-N43.   DOI
16 Sandstede JJ, Werner A, Kaupert C, et al. A prospective study comparing different iodine concentrations for triphasic multidetector row CT of the upper abdomen. Eur J Radiol 2006;60:95-99.   DOI
17 Han JK, Kim AY, Lee KY, et al. Factors influencing vascular and hepatic enhancement at CT: experimental study on injection protocol using a canine model. J Comput Assist Tomogr 2000;24:400-406.   DOI
18 Spielmann AL. Liver imaging with MDCT and high concentration contrast media. Eur J Radiol 2003;45 Suppl 1:S50-S52.   DOI
19 Bae KT. Peak contrast enhancement in CT and MR angiography: when does it occur and why? Pharmacokinetic study in a porcine model. Radiology 2003;227:809-816.   DOI
20 Matoba M, Kitadate M, Kondou T, Yokota H, Tonami H. Depiction of hypervascular hepatocellular carcinoma with 64-MDCT: comparison of moderate- and high-concentration contrast material with and without saline flush. AJR Am J Roentgenol 2009;193:738-744.   DOI
21 Hwang GJ, Kim MJ, Yoo HS, Lee JT. Nodular hepatocellular carcinomas: detection with arterial-, portal-, and delayed-phase images at spiral CT. Radiology 1997;202:383-388.   DOI
22 Mitsuzaki K, Yamashita Y, Ogata I, Nishiharu T, Urata J, Takahashi M. Multiple-phase helical CT of the liver for detecting small hepatomas in patients with liver cirrhosis: contrast-injection protocol and optimal timing. AJR Am J Roentgenol 1996;167:753-757.   DOI
23 Bae KT, Heiken JP, Brink JA. Aortic and hepatic peak enhancement at CT: effect of contrast medium injection rate: pharmacokinetic analysis and experimental porcine model. Radiology 1998;206:455-464.   DOI
24 Yamashita Y, Komohara Y, Takahashi M, et al. Abdominal helical CT: evaluation of optimal doses of intravenous contrast material: a prospective randomized study. Radiology 2000;216:718-723.   DOI
25 Awai K, Takada K, Onishi H, Hori S. Aortic and hepatic enhancement and tumor-to-liver contrast: analysis of the effect of different concentrations of contrast material at multi-detector row helical CT. Radiology 2002;224:757-763.   DOI
26 Marchiano A, Spreafico C, Lanocita R, et al. Does iodine concentration affect the diagnostic efficacy of biphasic spiral CT in patients with hepatocellular carcinoma? Abdom Imaging 2005;30:274-280.   DOI
27 Behrendt FF, Mahnken AH, Stanzel S, et al. Intraindividual comparison of contrast media concentrations for combined abdominal and thoracic MDCT. AJR Am J Roentgenol 2008;191:145-150.   DOI
28 Schoellnast H, Brader P, Oberdabernig B, et al. High-concentration contrast media in multiphasic abdominal multidetector-row computed tomography: effect of increased iodine flow rate on parenchymal and vascular enhancement. J Comput Assist Tomogr 2005;29:582-587.   DOI
29 Walkey MM. Dynamic hepatic CT: how many years will it take 'til we learn? Radiology 1991;181:17-18.   DOI
30 Furuta A, Ito K, Fujita T, Koike S, Shimizu A, Matsunaga N. Hepatic enhancement in multiphasic contrast-enhanced MDCT: comparison of high- and low-iodine-concentration contrast medium in same patients with chronic liver disease. AJR Am J Roentgenol 2004;183:157-162.   DOI