Browse > Article
http://dx.doi.org/10.9714/psac.2016.18.3.021

A simulation study on the variation of virtual NMR signals by winding, bobbin, spacer error of HTS magnet  

Kim, Junseong (Yonsei University)
Lee, Woo Seung (Yonsei University)
Kim, Jinsub (Yonsei University)
Song, Seunghyun (Yonsei University)
Nam, Seokho (Yonsei University)
Jeon, Haeryong (Yonsei University)
Baek, Geonwoo (Yonsei University)
Ko, Tae Kuk (Yonsei University)
Publication Information
Progress in Superconductivity and Cryogenics / v.18, no.3, 2016 , pp. 21-24 More about this Journal
Abstract
Recently, production technique and property of the High-Temperature Superconductor (HTS) tape have been improved. Thus, the study on applying an HTS magnet to the high magnetic field application is rapidly increased. A Nuclear Magnetic Resonance (NMR) spectrometer requires high magnitude and homogeneous of central magnetic field. However, the HTS magnet has fabrication errors because shape of HTS is tape and HTS magnet is manufactured by winding HTS tape to the bobbin. The fabrication errors are winding error, bobbin diameter error, spacer thickness error and so on. The winding error occurs when HTS tape is departed from the arranged position on the bobbin. The bobbin diameter and spacer thickness error occur since the diameter of bobbin and spacer are inaccurate. These errors lead magnitude and homogeneity of central magnetic field to be different from its ideal design. The purpose of this paper is to investigate the effect of winding error, bobbin diameter error and spacer thickness error on the central field and field homogeneity of HTS magnet using the virtual NMR signals in MATLAB simulation.
Keywords
NMR magnet; HTS magnet; Manufacturing error; Fabrication error; Winding error; Spacer thickness error; Bobbin diameter error;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Y. Iwasa, "HTS and NMR/MRI magnets: Unique features, opportunities, and challenges," Phys. C Supercond. its Appl., vol. 445-448, no. 1-2, pp. 1088-1094, 2006.   DOI
2 W. D. Markiewicz, J. R. Miller, J. Schwartz, U. P. Trociewitz, and H. W. Weijers, "Perspective on a superconducting 30 T/1.3 GHz NMR spectrometer magnet," IEEE Trans. Appl. Supercond., vol. 16, no. 2, pp. 1523-1526, 2006.   DOI
3 S. Y. Hahn, M. C. Ahn, E. S. Bobrov, J. Bascunn, and Y. Iwasa, "An analytical technique to elucidate field impurities from manufacturing uncertainties of an double pancake type hts insert for high field lts/hts nmr magnets," IEEE Trans. Appl. Supercond., vol. 19, no. 3, pp. 2281-2284, 2009.   DOI
4 A. Chanc and G. Aubert, "Relations Between the Winding Errors of the Double Pancakes and the Spherical Harmonics Expansion of the Field," IEEE Trans. Appl. Supercond., vol. 19, no. 6, pp. 3795-3804, 2009.   DOI
5 S. Yoon, J. Kim, H. Lee, S. Hahn, and S.-H. Moon, "26 T 35 mm all-$GdBa_2Cu_3O_{7-x}$ multi-width no-insulation superconducting magnet," Supercond. Sci. Technol., vol. 29, no. 4, p. 04LT04, 2016.   DOI
6 F. X. Li, J. P. Voccio, M. C. Ahn, S. Hahn, J. Bascunan, and Y. Iwasa, "An analytical approach towards passive ferromagnetic shimming design for a high-resolution NMR magnet," Supercond. Sci. Technol., vol. 28, no. 7, p. 075006, 2015.   DOI