2006.11a
-
-
-
-
-
-
-
-
-
-
-
This paper describes NDIR
$CO_2$ gas sensor that shows the characteristics of temperature compensation. It consists of novel optical cavity that has two elliptical mirrors and a thermopile detector that includes ASIC chip in the same metal package for the amplification of detector output voltage and temperature sensor. The newly developed sensor modules shows high accuracy (less than +/-40 ppm) throughout the measuring concentration of$CO_2$ gas from 0 ppm to 2,000 ppm. After implementing the calculation methods of gas concentration, which is based upon the experimental results, the sensor module shows high accuracy less than +/- 5 ppm error throughout the measuring temperature range$(15^{\circ}C\;to\; 35^{\circ}C)$ and gas concentrations. -
Lee, Il-Kwon;Kim, Chung-Kyun;Kim, Han-Goo;Lee, Byung-Kwan;Kim, Young-Gyu;Kim, Do-Hyun;Kim, Tae-Hwan;Oh, Kyung-Seok;Kook, Chang-Ho 129
-
-
-
-
-
-
-
-
전력선에 지락고장이 발생할 경우 대지로 유입된 고장전류에 의하여 인접한 배관에 아크 용융이 발생하면 가스폭발이나 기름유출과 같은 대형사고를 발생시킬 수 있으며, 배관의 유지 및 보수를 담당하는 작업자의 안전에도 위험을 초래할 수 있다. 본 논문에서는 대지를 통한 철탑과 배관 사이의 아크 발생에 대하여 알아보고, 국내외에서 사용되고 있는 철탑 인근에 매설된 배관의 이격거리 기준을 조사하였다.
-
-
-
-
-
LNG 냉열 활용에 대한 관심은 유가의 고공행진과 더불어 고조되고 있다. 본 연구는 생산기지 내에서 LNG 냉열의 이용현황 및 활용 가능량에 대한 분석을 토대로 LNG를 사용하는 6대 냉열사업에 대한 타당성 연구를 수행하였다 하절기 생산기지 내에서 냉열의 활용 가능량은 전체 냉열량의 30%로 LNG kg당 약 60kcal 정도로 매우 적다. 또한 생산기지 내에서 천연가스 송출량이 시간대별로 크게 차이가 발생되기 때문에 실질적으로 활용 가능한 양은 이것보다 적은 것으로 나타났다. 6대 냉열사업은 공기액화분리, 냉열발전, 저온분쇄, 액화탄산 및 드라이아이스, 냉동 및 냉장창고, 지역냉방사업이고, 사업화 가능성에 대한 타당성 연구를 수행하였다. 본 결과 전체 냉열사업의 투자비 회수기간이 15년 이상 상회하는 것으로 나타났다. 현시점에서 냉열사업 자체의 외국기술 의존도 때문에 막대한 초기투자비가 필요하고, 생산품의 부가가치가 낮으며 기존 시장에서 경쟁력을 확보하기가 어려운 것으로 평가되었다.
-
-
-