Method development for complex low molecular mass (LMM) samples using reversed-phase (RP) separation conditions presents significant challenges due to the presence of many unknown analytes over wide concentration ranges. This guide aims to optimize method parameters-column length (L), temperature (T), flow rate (F), and final mobile phase conditions (Øfinal)-to maximize separation peak capacity. Validated by prior research, this protocol benefits laboratories dealing with metabolomics, natural products, and contaminant screening. This practical guide provides a structured approach to maximizing peak capacity for complex LMM separations. It complements computational optimization strategies and offers a step-by-step method development process. The Snyder-Dolan test is highlighted as essential for determining the need for gradient or isocratic elution and guiding column length decisions. The decision tree framework helps analysts prioritize variable optimization to develop effective separation methods for complex samples.

Keywords

References

  1. A. Soliven, I.A. Haidar Ahmad, M.R. Filgueira, P.W. Carr, J. Chromatogr. A 1273 (2013) 57-65.
  2. A. Soliven, I.A. Haidar Ahmad, M.R. Filgueira, P.W. Carr, J. Chromatogr. A 1315 (2013) 204.
  3. J.W. Dolan, L.R. Snyder, N.M. Djordjevic, D.W. Hill, T.J. Waeghe, J. Chromatogr. A 857 (1999) 1-20.
  4. U.D. Neue, J. Chromatogr. A 1079 (2005) 153-161.
  5. Avantor® ACE® Application Note #3120 H300 Pesticides by LC-MS/MS" (https://av.cmd2.vwr.com/pub/apl/chrom/main?key=C-12495)
  6. D.R. Stoll, X. Li, X. Wang., P.W. Carr, S. Porter, S. Rutan, J. Chromatogr. A 1168 (2007) 3-43.
  7. I.A.H. Ahmad, A. Soliven, R.C. Allen, M. Filgueira, P.W. Carr, J. Chromatogr. A 1386 (2015) 31-38.
  8. X. Wang, W.E. Barber, P.W. Carr, J. Chromatogr. A 1107 (2006) 139-151.
  9. Avantor® ACE® Technical Note #036 "Increasing Gradient Peak Capacity for the Analysis of Protein Digests and other Complex Samples" (https://av.cmd2.vwr.com/pub/apl/chrom/main?key=C-13279)
  10. L.R. Snyder, J.W. Dolan, High-Performance Gradient Elution: The Practical Application of the Linear-Solvent-Strength Model, John Wiley & Sons, Inc., 2007.
  11. Avantor® ACE® Knowledge Note #0012 "Understanding the Relationship between Particle Size, Performance and Pressure11 (https://uk.vwr.com/2ms/ace_knowledge_notes)
  12. Avantor® ACE® Knowledge Note #0013 "The power of Stationary Phase Selectivity11 (https://uk.vwr.com/zms/ace_knowledge_notes)
  13. Avantor® ACE® white paper "Solid core particles: Application to small molecule LC analysis" (https://uk.vwr.com/cms/zhromatography_white_papers_and_detailed_investigations)