가스 크로마토그래피 캐필러리 컬럼 설치 가이드

GC Capillary Column Installation

  • Matt James ( Avantor Korea) ;
  • Kirsty Ford (Avantor Korea)
  • 발행 : 2024.06.26

초록

This article provides detailed instructions for the correct installation, maintenance, and troubleshooting of capillary gas chromatography (GC) columns. It emphasizes the importance of proper installation to ensure optimal performance and longevity of the column. The document covers various aspects such as column trimming, installation, conditioning, testing, storage, and ferrule selection. The installation process involves ensuring that the heated zones of the GC are cool before placing the column cage in the column oven. It is essential to avoid sharp bends or stress on the capillary column during installation and to connect the front end of the column into the GC inlet at the recommended insertion distance. The document also provides guidance on trimming the column, including the use of a ceramic wafer or capillary column cutter to achieve a clean, burr-free cut. For previously used columns, it recommends removing any capillary caps, positioning the nut and ferrule, and trimming 1-2 cm from the column. After installation, the column should be purged with carrier gas to remove any oxygen and avoid oxidizing the column. Conditioning the column involves ramping to the upper isothermal temperature limit and maintaining this temperature for a specified duration. It is crucial to maintain carrier gas flow during conditioning and not exceed the upper temperature limit of the column to avoid phase damage. The document also discusses testing column performance using a suitable method and performing a test injection to assess performance. It provides recommendations for column storage, including flame-sealing the capillary ends or using retention gaps for long-term storage. Additionally, it emphasizes the importance of routine maintenance and replacement of GC consumables to extend the column's lifetime. Ferrule selection is another important aspect covered in the article, with a variety of ferrule materials available for different applications. The characteristics of common ferrule options are presented in a table, including temperature limits, reusability, and suitability for specific detector types.

키워드

참고문헌

  1. "The LCGC Blog: GC Inlet Maintenance...have you really heard it all before?," 2014. [Online]. Available: https://www.chromatographyonline.com/view/lcgc-blog-gc-inlet-maintenancehave-you-really-heard-it-all.
  2. D. Rood, "Gas Chromatography Problem Solving and Troubleshooting," Journal of Chromatoqraphic Science(2001) 39, 309-310. https://doi.org/10.1093/chromsci/39.7.309
  3. E. F. Barry and R. L. Grob, Columns for Gas Chromatography Performance and Selection, New Jersey: John Wiley & Sons Inc, 2007.