DOI QR코드

DOI QR Code

Study on wind resistance performance and failure mechanism of reinforcement systems for standing seam metal roofs

  • Zhitao Zheng (China Construction Fifth Engineering Division Second Construction Co., Ltd) ;
  • Wenbing Shen (China Construction Fifth Engineering Division Second Construction Co., Ltd) ;
  • Chuang Li (China Construction Fifth Engineering Division Second Construction Co., Ltd) ;
  • Sheng Li (China Construction Fifth Engineering Division Second Construction Co., Ltd) ;
  • Hongliang Deng (China Construction Fifth Engineering Division Second Construction Co., Ltd) ;
  • Mengjie Lu (China Construction Fifth Engineering Division Second Construction Co., Ltd) ;
  • Cheng Zhang (China Construction Fifth Engineering Division Second Construction Co., Ltd)
  • 투고 : 2024.04.25
  • 심사 : 2024.09.16
  • 발행 : 2024.10.25

초록

The current research on the wind resistance of standing seam metal roofs primarily focuses on the failure modes of the entire roof panel and the contact areas between the seams and supports, with little consideration given to the synergy between the roof seam reinforcements, the web, and the supports. As a result, the failure mechanisms of roof systems cannot be accurately represented. This paper, based on wind uplift tests and ABAQUS simulation modeling, provides a detailed analysis of the wind resistance and failure mechanisms of reinforced standing seam metal roof systems. The study reveals that the deformation and failure of the roof system under wind load can be divided into three stages: elastic deformation, plastic deformation, and failure. In the elastic deformation stage, the areas with higher stress are mainly distributed in the mid-span of the roof panels and along the ribs, where the roof stress remains below the material's yield strength, and the displacement at the roof panel seams is minimal. During the plastic deformation stage, as the load increases, significant vertical deformations appear in the roof panels, the lateral displacement at the seams gradually increases, and the stress growth is pronounced. Without reinforcement, the roof panel withstands a maximum wind pressure of 3.2 kPa, with a central vertical displacement of 109 mm, while the ultimate lateral displacement at the seams reaches 2.3 mm, resulting in unseating failure, marking the structural failure. With reinforcement, the roof panel can withstand a maximum wind pressure of 4.3 kPa, corresponding to a central vertical displacement of 122 mm. The growth of lateral displacement at the seams slows down, and the reinforcement significantly suppresses seam displacement. As the load continues to increase, the reinforcements and the web work synergistically, exhibiting reciprocating counterclockwise and clockwise rotations, with the maximum lateral displacement at the seams increasing to 3.05 mm. Ultimately, unseating occurs at the roof panel seams or tearing at the web. Therefore, the reinforcement system significantly enhances the wind resistance of the roof system, providing theoretical guidance for wind-resistant design in roofing engineering.

키워드

과제정보

The research described in this paper was financially supported by the Anhui Provincial Department of Housing and Urban-Rural Development [Grant Numbers: 2023-YF104 and 2023-YF-010] and China Construction fifth Engineering Bureau youth project funding project [Grant Numbers: cscec5b-2023-Q-02].

참고문헌

  1. Azzi, Z., Habte, F., Vutukuru, K.S., Gan Chowdhury, A., Moravej, M. (2020), "Effects of roof geometric details on aerodynamic performance of standing seam metal roofs", Eng. Struct., 225, 111303. https://doi.org/10.1016/j.engstruct.2020.111303.
  2. ASCE (2002), Specification for the Design of Cold-Formed Stainless Steel Structural Members: ASCE 8-02-2002. Reston, VA: ASCE.
  3. AS1562.1-2018: Australian Standard. (2018), AS 1562.1:2018 - Design and Installation of Sheet Roof and Wall Cladding - Metal. Standards Australia.
  4. AS4040.3-2018: Australian Standard (2018), AS 4040.3:2018 - Methods of Testing Roofs Under Wind Loads - Determination of Resistance to Wind Pressures for Cyclone Regions. Standards Australia.
  5. Baskaran, B.A., Ping Ko, S.K. and Molleti, S. (2009), "A novel approach to estimate the wind uplift resistance of roofing systems", Build. Environ., 44(4), 723-735. https://doi.org/10.1016/j.buildenv.2008.06.024.
  6. BSI. Eurocode 9 (2007), Design of Aluminium Structures: Part 1-4: Cold-formed Structural Sheeting: EN-1999-1-4:2007. London: BSI.
  7. Cui, Z.Q. (2019), "Studies on the Performance of Standing Seam Metal Roof under Wind Uplift Load", China Academy of Building Science.
  8. Chen, Y. (2015), "Investigation on wind load bearing capacity of standing seam roofing systems", Beijing: Beijing Jiaotong University.
  9. Habte, F., Asghari Mooneghi, M., Gan Chowdhury, A. and Irwin, P. (2015), "Full-scale testing to evaluate the performance of standing seam metal roofs under simulated wind loading", Eng. Struct., 105, 231-248. https://doi.org/10.1016/j.engstruct.2015.10.006.
  10. Kasperski, M. (1996), "Design wind loads for low-rise buildings: A critical review of wind load specifications for industrial buildings", J. Wind Eng. Ind. Aerod., 61(2), 169-179. https://doi.org/10.1016/0167-6105(96)00051-7.
  11. Liang, J. and Wang, X. (2009), "Investigation and analysis of roof wind disaster accidents in a gymnasium. guangdong civil", Eng. Architect., 16(12), 11-14. https://doi.10.19731/j.gdtmyjz.2009.12.003.
  12. Lu, Q., Li, M., Zhang, M., Min, Q., Zhang, Y. and Liu, X. (2022), "Wind-resistance performance investigation of 360° vertical seam-locked roof system reinforced by sliding support and sandwich panel", J. Build. Eng., 45, 103689. https://doi.org/10.1016/j.jobe.2021.103689.
  13. Luan, W. and Li, Y.-Q. (2019), "Experimental investigation on wind uplift capacity of single span Z-purlins supporting standing seam roof systems", Thin-Wall. Struct., 144, 106324. https://doi.org/10.1016/j.tws.2019.106324.
  14. Mobasher, M.E., Adams, B., Mould, J., Hapij, A. and Londono, J. G. (2022). "Damage mechanics based analysis of hail impact on metal roofs", Eng. Fracture Mech., 272, 108688. https://doi.org/10.1016/j.engfracmech.2022.108688.
  15. Min, Q., Li, N., Zhang, Y., Lu, Q. and Liu, X. (2021), "A novel wind resistance sliding support with large sliding displacement and high tensile strength for metal roof system", Eng. Struct., 243, 112670. https://doi.org/10.1016/j.engstruct.2021.112670.
  16. Pratap, A., Rani, N. (2022), "Review of international wind codes and recent research on mono-slope canopy roof", Wind Struct., 34(4), 371-383. https://doi.org/10.12989/WAS.2022.34.4.371.
  17. Serrette, R. and Pekoz, T. (1997), "Bending strength of standing seam roof panels", Steel Aluminium Struct., 27(1), 55-64. https://doi.org/10.1016/0263-8231(96)00018-3.
  18. Seek, M.W., Avci, O. and McLaughlin, D. (2021), "Effective standoff in standing seam roof systems", J. Construct. Steel Res., 180, 106590. https://doi.org/10.1016/j.jcsr.2021.106590.
  19. Sun, Y., Wu, T. and Cao, Z. (2021), "Wind vulnerability analysis of standing seam roof system with consideration of multistage performance levels", Thin-Wall. Struct,, 165, 107942. https://doi.org/10.1016/j.tws.2021.107942.
  20. Technical Specification for Skylights and Metal Roofing: JGJ 255- (2012), S. Beijing: China Architecture & Building Press.
  21. Wei, G., Schafer, B.W., Seek, M. and Eatherton, M.R. (2024), "Evaluating the use of standing seam roof as beam lateral bracing", J. Construct. Steel Res., 212, 108244. https://doi.org/10.1016/j.jcsr.2023.108244.
  22. Wu, T., Sun, Y., Cao, Z., Yu, Z. and Wu, Y. (2020), "Study on the wind uplift failure mechanism of standing seam roof system for performance-based design", Eng. Struct., 225, 111264. https://doi.org/10.1016/j.engstruct.2020.111264.
  23. Yang, L., Ye, C., Yang, X., Yang, X.Y. and Kou, J.G. (2023), "Fatigue wind load spectrum construction based on integration of turbulent wind model and measured data for long-span metal roof", Wind Struct., 36(2), 121-131. https://doi.org/10.12989/WAS.2023.36.2.121.
  24. Yang, Q., Liang, Q., Liu, M., Nie, S., Wang, Z. and Wu, H. (2024), "An equivalent spring model for seam-clip connections of high-vertical standing seam metal cladding systems", Thin-Wall. Struct., 195, 111368. https://doi.org/10.1016/j.tws.2023.111368.
  25. Yang, X.W., Zhou, Q., Lei, Y.F., Yang, Y. and Li, M.S. (2022), "Non-Gaussian features of dynamic wind loads on a long-span roof in boundary layer turbulences with different integral-scales", Wind Struct., 34(5), 421-435. https://doi.org/10.12989/WAS.2022.34.5.421.
  26. Zhang, G. (2017), "Analysis of wind resistance reinforcement methods for standing seam metal roofing in large public buildings", Wind Struct., 21, 28-32. https://doi.10.13616/j.cnki.gcjsysj.2017.11.004.