Abstract

Draft curtains are an important tool to reduce the spread of fire smoke in buildings. This paper mainly studies the influence of draft curtains on smoke spread in a hospital outpatient building with a spacious hall. The outpatient building of a county hospital in China is taken as the research object, and a fire simulation model is established based on PyroSim software. Four scenarios are designed: no draft curtains in the hall, draft curtains with a length of 1.5m in the hall, draft curtains with a length of 2.0m in the hall, and draft curtains with a length of 2.5m in the hall. At the same time, considering the worst situation, only the main emergency exit is opened, while the remaining emergency exits and windows are all closed, and the fire-fighting facilities are not activated. The detection point is set at the open emergency exit, 1.8m above the ground. Through the simulation of four scenarios, the effect of draft curtains on smoke spread is discussed from four aspects: smoke layer height, temperature, visibility, and CO concentration. The results show that draft curtains have a significant impact on the spread of smoke in a hospital outpatient building with a spacious hall. The longer the draft curtains are, the better the smoke-blocking effect. It should be noted that in the actual design, the length of the draft curtains should be considered without affecting the evacuation of personnel.

Keywords

References

  1. G. Hu, "Research on the Fire of High-rise Residential Building Based on Pyrosim Numerical Simulation," IOP Conference Series: Earth and Environmental Science, Vol. 455, pp. 1-5, January 2020. DOI: https://doi.org/10.1088/1755-1315/455/1/012059
  2. M. Xu, and D. Peng, "PyroSim-Based Numerical Simulation of Fire Safety and Evacuation Behaviour of College Buildings," International Journal of Safety and Security Engineering, Vol. 10, No. 2, pp. 293-299, April 2020. DOI: https://doi.org/10.18280/ijsse.100218
  3. Y. Ju, "A fire simulation method of urban light rail station hall based on building information model and pyrosim software," Journal of Physics: Conference Series, Vol. 1903, pp. 1-6, March 2021. DOI: https://doi.org/10.1088/1742-6596/1903/1/012065
  4. H. Zhang, Z. Miao, H. Lv, and Z. Leng, "Evacuation Simulation of Large Theater Based on Pyrosim and Pathfinder," Journal of Physics: Conference Series, Vol. 2289, pp. 1-8, April 2022. DOI: https://doi.org/10.1088/1742-6596/2289/1/012017
  5. H. Zheng, S. Zhang, J. Zhu, Z. Zhu, and X. Fang, "Evacuation in Buildings Based on BIM: Taking a Fire in a University Library as an Example," International Journal of Environmental Research and Public Health, Vol. 19, No. 23, pp. 1-21, December 2022. DOI: https://doi.org/10.3390/ijerph192316254
  6. L. Liao, H. Li, P. Li, X. Bao, C. Hong, D. Wang, X. Xie, J. Fan, and P. Wu, "Underground Evacuation and Smoke Flow Simulation in Guangzhou International Financial City during Fire," Fire, Vol. 6, No. 7, pp. 1-27, July 2023. DOI: https://doi.org/10.3390/fire6070266
  7. R.H. Ismail, and O.H. Kharufa, "The Effect of Plan Corner Shapes on the Spread Speed of Fire in High-Rise Buildings," International Journal of Safety and Security Engineering, Vol. 13, No. 4, pp. 685-691, September 2023. DOI: https://doi.org/10.18280/ijsse.130410
  8. S. Lu, P. Xu, L. Yao, and M. Li, "Numerical simulation of hospital ward fire characteristics under different water spray intensity," Standardization of Engineering Construction, Vol. 02, pp. 78-83, 2024. DOI: 10.13924/j.cnki.cecs.2024.02.037 (in Chinese)
  9. X. Dong, Y. Qi, W. Wang, P. Fu, T. Peng, and Q. Qi, "Simulation Study on Emergency Evacuation of Personnel in High-rise Building Fires--Taking Hospitals for Example," China Emergency Rescue, Vol. 02, pp. 30-37,2024. DOI: 10.19384/j.cnki.cn11-5524/p.2024.02.006 (in Chinese)
  10. W. Kim, and J. Hong, "A Study on the Reduced temperature and Improvement of Visibility during Ship's fire of Draft Curtain." The Journal of Fisheries and Marine Sciences Education, Vol. 34, No. 1, pp. 34-41, 2022. https://doi.org/10.13000/JFMSE.2022.2.34.1.34 (in Korean)
  11. Chinese Standard: 《Technical standard for smoke management systems in buildings》 GB 51251-2017