DOI QR코드

DOI QR Code

Radioiodine internal dose coefficients specific for Koreans

  • Tae-Eun Kwon (Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health) ;
  • Yoonsun Chung (Department of Nuclear Engineering, Hanyang University) ;
  • Choonsik Lee (Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health)
  • 투고 : 2023.11.21
  • 심사 : 2024.02.17
  • 발행 : 2024.07.25

초록

This study developed internal dose coefficients for radioiodine, tailored to the Korean population, by incorporating the Korean biokinetic model along with the Korean S values. The observed differences in dose coefficients for Koreans compared to the International Commission on Radiological Protection (ICRP) reference values noticeably varied depending on physical half-lives of iodine isotopes. For longer-lived isotopes such as I-125 and I-129, significant differences in thyroid dose coefficients were observed, with ratios (Korean/ICRP) from 0.30 to 0.55, indicating that actual doses for Koreans can be considerably lower than those evaluated based on the ICRP data. However, for short-lived iodine isotopes, such as I-131, the thyroid dose coefficients were comparable to the ICRP reference values (ratio = 0.95-0.98). These comparable dose coefficients resulted from the lower thyroidal iodine uptake in the Korean model being almost entirely offset by the higher thyroid self-absorption S values in the Korean phantoms. Additionally, this study delves into the substantial differences in absorbed dose coefficients for non-thyroidal regions and effective dose coefficients, which arose not only from physiological/anatomical variability but also technical differences in phantom design. The use of Korean-specific dose coefficients is advisable particularly in scenarios predicting elevated doses, yielding a more precise and clinically relevant dose assessment.

키워드

과제정보

This research was funded by the intramural research program of the National Institutes of Health (NIH), National Cancer Institute, Division of Cancer Epidemiology and Genetics.

참고문헌

  1. E. Kim, K. Yajima, S. Hashimoto, K. Tani, Y. Igarashi, T. Iimoto, N. Ishigure, H. Tatsuzaki, M. Akashi, O. Kurihara, Reassessment of internal thyroid doses to 1,080 children examined in a screening survey after the 2011 Fukushima nuclear disaster, Health Phys. 118 (2020) 36-52.
  2. W. Weiss, Chernobyl thyroid cancer: 30 years of follow-up overview, Radiat. Protect. Dosim. 182 (2018) 58-61.
  3. T.-E. Kwon, E. Pasqual, C.M. Kitahara, C. Lee, Absorbed dose coefficients for adult thyroid cancer patients undergoing radioiodine therapy, J. Radiol. Prot. 43 (2023) 021510.
  4. C.M. Kitahara, A. Berrington de Gonzalez, A. Bouville, A.B. Brill, M.M. Doody, D. R. Melo, S.L. Simon, J.A. Sosa, M. Tulchinsky, D. Villoing, D.L. Preston, Association of radioactive iodine treatment with cancer mortality in patients with hyperthyroidism, JAMA Intern. Med. 179 (2019) 1034.
  5. ICRP, Occupational Intakes of Radionuclides: Part 3 Ann ICRP, vol. 46, 2017, pp. 1-486.
  6. ICRP, Age-dependent Doses to Members of the Public from Intake of Radionuclides - Part 2 Ingestion Dose Coefficients ICRP Publication 67, ICRP, Ann, 1994.
  7. ICRP, Adult Reference Computational Phantoms ICRP Publication 110, Ann. ICRP, vol. 39, 2009, pp. 1-166.
  8. T.-E. Kwon, Y. Chung, Y.W. Jin, Korean-specific biokinetic model for iodine in radiological protection, J. Radiol. Prot. 41 (2021) 162-178.
  9. T.-E. Kwon, Y. Chung, C. Lee, Korean-specific iodine S values for use in internal dosimetry, Nucl. Eng. Technol. (2023). S173857332300414X.
  10. C. Choi, T.T. Nguyen, Y.S. Yeom, H. Lee, H. Han, B. Shin, X. Zhang, C.H. Kim, B. S. Chung, Mesh-type reference Korean phantoms (MRKPs) for adult male and female for use in radiation protection dosimetry, Phys. Med. Biol. 64 (2019) 085020.
  11. ICRP, Occupational Intakes of Radionuclides: Part 1 Ann ICRP, vol. 44, 2015, pp. 5-188.
  12. ICRP, Human alimentary tract model for radiological protection ICRP publication 100, Ann. ICRP 36 (2006) 1-336.
  13. ICRP, Dose Coefficients for Intakes of Radionuclides by Members of the Public: Part 1 Ann ICRP, 2023.
  14. T.-E. Kwon, M. Park, J.-K. Kang, M. Cho, S. Jang, K.M. Kim, W.-H. Ha, Y.W. Jin, Internal dose assessment after 131I-iodide misadministration in a patient with incompletely blocked thyroid uptake: personalized internal dose assessment by estimating individual-specific biokinetics, Health Phys. 116 (2019) 760-770.
  15. T.-E. Kwon, M. Park, G.-H. Jung, Y. Chung, W.-H. Ha, Y.W. Jin, Practical methods for internal dose assessment for radioiodine intake after thyroid blocking: classification of degree of blockage and determination of insensitive measurement point, Radiat. Protect. Dosim. 187 (2019) 69-76.
  16. ICRP, Use of dose quantities in radiological protection, Ann. ICRP 50 (2021) 9-82.
  17. ICRP, The 2007 Recommendations of the International Commission on Radiological Protection ICRP Publication 103, Ann. ICRP, vol. 37, 2007, pp. 1-332.
  18. Y.S. Yeom, D. Villoing, N. Greenstein, C.M. Kitahara, L.R. Folio, C.H. Kim, C. Lee, Investigation of the influence of thyroid location on Iodine-131 S values, Radiat. Protect. Dosim. 189 (2020) 163-171.
  19. ICRP, The ICRP computational framework for internal dose assessment for reference adults: specific absorbed fractions, Ann. ICRP 45 (2016) 1-74.
  20. R. Leggett, An age-specific biokinetic model for iodine, J. Radiol. Prot. 37 (2017) 864-882.
  21. ICRP, Age-dependent doses to members of the public from intake of radionuclides: Part 5. Compilation of ingestion and inhalation dose coefficients, Ann. ICRP 26 (1996) 1-91.
  22. H.S. Kim, Y.S. Yeom, T.T. Nguyen, C. Choi, M.C. Han, J. Lee, C.H. Kim, M. Zankl, N. Petoussi-Henss, W.E. Bolch, C. Lee, R. Qiu, K. Eckerman, B.S. Chung, Inclusion of thin target and source regions in alimentary and respiratory tract systems of mesh-type ICRP adult reference phantoms, Phys. Med. Biol. 62 (2017) 2132-2152.
  23. C.H. Kim, Y.S. Yeom, N. Petoussi-Henss, M. Zankl, W.E. Bolch, C. Lee, C. Choi, T. T. Nguyen, K. Eckerman, H.S. Kim, M.C. Han, R. Qiu, B.S. Chung, H. Han, B. Shin, ICRP Publication 145: Adult Mesh-type Reference Computational Phantoms Ann ICRP 49 13-201, 2020.