Acknowledgement
In part by the Korea Medical Device Development Fund grants funded by the Korean government (Ministry of Science and ICT, Ministry of Trade, Industry and Energy, Ministry of Health & Welfare, Ministry of Food and Drug Safety) (Project No. KMDF_PR_20200901_0024 and KMDF_PR_20200901_0026); In part by the National Research Council of Science & Technology (NST) grant by the Korea government (MSIT) (GTL24021-500); Development of Measurement Standards and Technology for Biomaterials and Medical Convergence funded by the Korea Research Institute of Standards and Science (Grant no. KRISS-GP2024-0007).
References
- A. Fouad, T. J. Pfefer, C.-W. Chen, W. Gong, A. Agrawal, P. H. Tomlines, P. D. Woolliams, R. A. Drezek, and Y. Chen, "Variations in optical coherence tomography resolution and uniformity: A multi-system performance comparison," Biomed. Opt. Express 5, 2066-2081 (2014). https://doi.org/10.1364/BOE.5.002066
- H.-J. Lee and S.-W. Lee, "Partial spectrum detection and super-Gaussian window function for ultrahigh-resolution spectral-domain optical coherence tomography with a linear-k spectrometer," Curr. Opt. Photonics 7, 73-82 (2023). https://doi.org/10.3807/COPP.2023.7.1.73
- A. Agrawal, C.-W. Chen, J. Baxi, Y. Chen, and T. J. Pfefer, "Multilayer thin-film phantoms for axial contrast transfer function measurement in optical coherence tomography," Biomed. Opt. Express 4, 1166-1175 (2013). https://doi.org/10.1364/BOE.4.001166
- M. M. Amaral, D. M. Zezell, A. F. G. Monte, A. C. B. de Cara, J. C. R. Araujo, A. Antunes, and A. Z. Freitas, "General model for depth-resolved estimation of the optical attenuation coefficients in optical coherence tomography," J. Biophotonics 12, e201800402 (2019).
- J. Liu, N. Ding, Y. Yu, X. Yuan, S. Luo, J. Luan, Y. Zhao, Y. Wang, and Z. Ma, "Optimized depth-resolved estimation to measure optical attenuation coefficients from optical coherence tomography and its application in cerebral damage determination," J. Biomed. Opt. 24, 035002 (2019).
- H.-J. Lee, N. M. Sauiudin, I. Doh, and S.-W. Lee, "Full layer retinal phantom mimicking three retinal vascular networks and curvature," Proc. SPIE PC12833, PC128330C (2024).
- F. Ratto, L. Cavigli, C. Borri, S. Centi, G. Magni, M. Mazzoni, and R. Pini, "Hybrid organosilicon/polyol phantom for photoacoustic imaging," Biomed. Opt. Express 10, 3719-3730 (2019). https://doi.org/10.1364/BOE.10.003719
- M. Dantuma, R. van Dommelen, and S. Manohar, "Semi-anthropomorphic photoacoustic breast phantom," Biomed. Opt. Express 10, 5921-5939 (2019). https://doi.org/10.1364/BOE.10.005921
- A. Hariri, J. Palma-Chavez, K. A. Wear, T. J. Pfefer, J. V. Jokerst, and W. C. Vogt, "Polyacrylamide hydrogel phantoms for performance evaluation of multispectral photoacoustic imaging systems," Photoacoustics 22, 100245 (2021).
- W. C. Vogt, X. Zhou, R. Andriani, K. A. Wear, T. J. Pfefer, and B. S. Garra, "Photoacoustic oximetry imaging performance evaluation using dynamic blood flow phantoms with tunable oxygen saturation," Biomed. Opt. Express 10, 449-464 (2019). https://doi.org/10.1364/BOE.10.000449
- L. Leggio, S. Gawali, D. Gallego, S. Rodriguez, M. Sanchez, G. Carpintero, and H. Lamela, "Optoacoustic response of gold nanorods in soft phantoms using high-power diode laser assemblies at 870 and 905 nm," Biomed. Opt. Express 8, 1430-1440 (2017). https://doi.org/10.1364/BOE.8.001430
- J. Ki, H. Lee, T. Lee, S.-W. Lee, J.-S. Wi, and H.-K. Na, "Visualization materials using silicon-based optical nanodisks (ViSiON) for enhanced NIR imaging in ophthalmology," Adv. Healthc. Mater. 13, 2303713 (2024).
- M. Izzetoglu, K. Pourrezaei, J. Du, and P. A. Shewokis, "Evaluation of cerebral tissue oximeters using multilayered dynamic head models," IEEE Trans. Instrum. Meas. 70, 1003112 (2021).
- Z. Kovacsova, G. Bale, S. Mitra, F. Lange, and I. Tachtsidis, "Absolute quantification of cerebral tissue oxygen saturation with multidistance broadband NIRS in newborn brain," Biomed. Opt. Express 12, 907-925 (2021). https://doi.org/10.1364/BOE.412088
- C. Akitegetse, P. Landry, J. Robidoux, N. Lapointe, D. Brouard, and D. Sauvageau, "Monte-Carlo simulation and tissue-phantom model for validation of ocular oximetry," Biomed. Opt. Express 13, 2929-2946 (2022). https://doi.org/10.1364/BOE.458079
- L. Wang, J. M. Cochran, T. Ko, W. B. Baker, K. Abramson, L. He, D. R. Busch, V. Kavuri, R. L. Linn, S. Parry, A. G. Yodh, and N. Schwartz, "Non-invasive monitoring of blood oxygenation in human placentas via concurrent diffuse optical spectroscopy and ultrasound imaging," Nat. Biomed. Eng. 6, 1017-1030 (2022). https://doi.org/10.1038/s41551-022-00913-2
- M. Damodaran, A. Amelink, and J. F. De Boer, "Optimal wavelengths for subdiffuse scanning laser oximetry of the human retina," J. Biomed. Opt. 23, 086003 (2018).
- S. Kleiser, N. N. Asseri, B. A. Ndresen, G. G. Reisen, and M. W. Olf, "Comparison of tissue oximeters on a liquid phantom with adjustable optical properties," Biomed. Opt. Express 7, 2973-2992 (2016). https://doi.org/10.1364/BOE.7.002973
- K. Rackebrandt and H. Gehring, "Calibration and evaluation of a continuous wave multi-distance NIRS system in simulated desaturation investigations," Biomed. Phys. Eng. Express 2, 035017 (2016).
- M. Fonseca, B. Zeqiri, P. Beard, and B. Cox, "Characterisation of a PVCP-based tissue-mimicking phantom for quantitative photoacoustic imaging," Proc. SPIE 9539, 953911 (2015).
- S. E. Bohndiek, S. Bodapati, D. V. De Sompel, S.-R. Kothapalli, and S. S. Gambhir, "Development and application of stable phantoms for the evaluation of photoacoustic imaging instruments," PLoS One 8, e75533 (2013).
- J. R. Cook, R. R. Bouchard, and S. Y. Emelianov, "Tissue-mimicking phantoms for photoacoustic and ultrasonic imaging," Biomed. Opt. Express 2, 3193-3206 (2011). https://doi.org/10.1364/BOE.2.003193
- D. M. de Bruin, R. H. Bremmer, V. M. Kodach, R. de Kinkelder, J. van Marle, T. G. van Leeuwen, and D. J. Faber, "Optical phantoms of varying geometry based on thin building blocks with controlled optical properties," J. Biomed. Opt. 15, 025001 (2010).
- P. C. Beard, "Photoacoustic imaging of blood vessel equivalent phantoms," Proc. SPIE 4618, 54-62 (2002). https://doi.org/10.1117/12.469848
- S. O. Isikman, A. Greenbaum, W. Luo, A. F. Coskun, and A. Ozcan, "Giga-pixel lensfree holographic microscopy and tomography using color image sensors," PLoS One 7, e45044 (2012).
- E. Mudry, P. C. Chaumet, K. Belkebir, G. Maire, and A. Sentenac, "Mirror-assisted tomographic diffractive microscopy with isotropic resolution," Opt. Lett. 35, 1857-1859 (2010). https://doi.org/10.1364/OL.35.001857
- J. Sun, B. Yang, N. Koukouraki, J. Guck, and J. W. Czarske, "AI-driven projection tomography with multicore fibre-optic cell rotation," Nat. Commun. 15, 147 (2024).
- B. Bazow, T. Phan, C. B. Raub, and G. Nehmetallah, "Three-dimensional refractive index estimation based on deep-inverse non-interferometric optical diffraction tomography (ODT-deep)," Opt. Express 31, 28382-28399 (2023). https://doi.org/10.1364/OE.491707
- E. Wdowiak, M. Zeimczonok, J. Martinez-Carranza, and A. Kus, "Phase-assisted multi-material two-photon polymerization for extended refractive index range," Addit. Manuf. 73, 103666 (2023).
- P. Zdankowski, J. Winnik, K. Patorski, P. Goclowski, M. Ziemczonok, M. Jozwik, M. Kujawinska, and M. Trusiak, "Common-path intrinsically achromatic optical diffraction tomography," Biom. Opt. Express 12, 4219-4234 (2021). https://doi.org/10.1364/BOE.428828
- M. Ziemczonok, A. Kus, P. Wasylczyk, and M. Kujawinska, "3D-printed biological cell phantom for testing 3D quantitative phase imaging systems," Sci. Rep. 9, 18872 (2019).
- A. Curatolo, B. F. Kennedy, and D. D. Sampson, "Structured three-dimensional optical phantom for optical coherence tomography," Opt. Express 19, 19480-19485 (2011). https://doi.org/10.1364/OE.19.019480
- A. Curatolo, P. R. T. Munro, D. Lorenser, P. Sreekumar, C. C. Singe, B. F. Kennedy, and D. D. Sampson, "Quantifying the influence of Bessel beams on image quality in optical coherence tomography," Sci. Rep. 6, 23483 (2016).
- A. Agrawal, T. J. Pfefer, P. D. Woolliams, P. H. Tomlins, and G. Nehmetallah, "Methods to assess sensitivity of optical coherence tomography systems," Biomed. Opt. Express 8, 902-917 (2017). https://doi.org/10.1364/BOE.8.000902
- N. Huang, Z. Deng, Z. Hu, J. Mei, S. Zhao, X. Wu, Z. Jia, Y. Liu, J. Wang, Q. Ye, and J. Tian, "A spatial resolution evaluation method of endoscopic optical coherence tomography system using the annular phantom," J. Biophotonics 14, e202100035 (2021).
- F. Zvietcovich, J. P. Rolland, J. Yao, P. Meemon, and K. J. Parker, "Comparative study of shear wave-based elastography techniques in optical coherence tomography," J. Biomed. Opt. 22, 035010 (2017).
- V. Jaedicke, S. Agcaer, F. E. Robles, M. Steinert, D. Jones, S. Goebel, N. C. Gerhardt, H. Welp, and M. R. Hofmann, "Comparison of different metrics for analysis and visualization in spectroscopic optical coherence tomography," Biomed. Opt. Express 4, 2945-2961 (2013). https://doi.org/10.1364/BOE.4.002945
- S. Chang, J. Handwerker, G. A. Giannico, S. S. Chang, and A. K. Bowden, "Birefringent tissue-mimicking phantom for polarization-sensitive optical coherence tomography imaging," J. Biomed. Opt. 27, 074711 (2022).
- F. Liu, G. Liu, and X. Wang, "High-accurate and robust fingerprint anti-spoofing system using optical coherence tomography," Expert. Syst. Appl. 130, 31-44 (2019). https://doi.org/10.1016/j.eswa.2019.03.053
- B. Vuong, P. Skowron, T.-R. Kiehl, M. Kyan, L. Garzia, C. Sun, M. D. Taylor, and V. X. Yang, "Measuring the optical characteristics of medulloblastoma with optical coherence tomography," Biomed. Opt. Express 6, 1487-1501 (2015). https://doi.org/10.1364/BOE.6.001487
- S. S. Gao, G. Liu, D. Huang, and Y. Jia, "Optimization of the split-spectrum amplitude-decorrelation angiography algorithm on a spectral optical coherence tomography system," Opt. Lett. 40, 2305-2308 (2015). https://doi.org/10.1364/OL.40.002305
- H.-J. Lee, N. M. Samiudin, T. Lee, I. Doh, and S.-W. Lee, "Retina phantom for the evaluation of optical coherence tomography angiography based on microfluidic channels," Biomed. Opt. Express 10, 5535-5548 (2019). https://doi.org/10.1364/BOE.10.005535
- J. Palma-Chavez, K. A. Wear, Y. Mantri, J. V. Jokerst, and W. C. Vogt, "Photoacoustic imaging phantoms for assessment of object detectability and boundary buildup artifacts," Photoacoustics 26, 100348 (2022).
- M. K. Kim, "Principles and techniques of digital holographic microscopy," SPIE Rev. 1, 018005 (2010).
- S. Tomioka, S. Nishiyama, N. Miyamoto, D. Kando, and S. Heshmat, "Weighted reconstruction of three-dimensional refractive index in interferometric tomography," Appl. Opt. 56, 6755-6764 (2017). https://doi.org/10.1364/AO.56.006755
- X. Yu, J. Hong, C. Liu, and M. K. Kim, "Review of digital holographic microscopy for three-dimensional profiling and tracking," Opt. Eng. 53, 112306 (2014).
- J. Zhang, J. Di, Y. Li, T. Xi, and J. Zhao, "Dynamical measurement of refractive index distribution using digital holographic interferometry based on total internal reflection," Opt. Express 23, 27328-27334 (2015). https://doi.org/10.1364/OE.23.027328
- Y. Kim, S. Park, H.-J. Choi, and S.-W. Min, "Refractive index measurement using self-interference incoherent digital holography," in Proc. 2022 IEEE International Conference on Consumer Electronics-ICCE (Las Vegas, NV, USA, Jan. 7-9, 2022), pp. 1-3.
- C. Sun, Y. Cui, Z. Wang, and Z. Jiang, "Measurement of microfluidic refractive index by digital holographic microscopy," in Laser Applications to Chemical, Security and Environmental Analysis 2018 (Optica Publishing Group, 2018), paper JW4A.29.
- I. H. Kwon, J. Lee, H.-K. Na, T. G. Lee, and S.-W. Lee, "Numerical phase-detection autofocusing method for digital holography reconstruction processing," Appl. Phys. Lett. 124, 093701 (2024).
- P. C. Chaumet, K. Belkebir, and A. Sentenac, "Numerical study of grating-assisted optical diffraction tomography," Phys. Rev. A 76, 013814 (2007).
- Y. Ruan, P. Bon, E. Mudry, G. Maire, P. C. Chaumet, H. Giovannini, K. Belkebir, A. Talneau, B. Wattellier, S. Monneret, and A. Sentenac, "Tomographic diffractive microscopy with a wavefront sensor," Opt. Lett. 37, 1631-1633 (2012). https://doi.org/10.1364/OL.37.001631
- C. Hornberger and H. Wabnitz, "Approaches for calibration and validation of near-infrared optical methods for oxygenation monitoring," Biomed. Tech. (Biomedizinische Technik) 63, 537-546 (2018). https://doi.org/10.1515/bmt-2017-0116
- A. Sudakou, H. Wabnitz, A. Liemert, M. Wolf, and A. Liebert, "Two-layered blood-lipid phantom and method to determine absorption and oxygenation employing changes in moments of DTOFs," Biomed. Opt. Express 14, 3506-3531 (2023). https://doi.org/10.1364/BOE.492168
- G. Liu, K. Huang, Q. Jia, S. Liu, S. Shen, J. Li, E. Dong, P. Lemaillet, D. W. Allen, and R. X. Xu, "Fabrication of a multilayer tissue-mimicking phantom with tunable optical properties to simulate vascular oxygenation and perfusion for optical imaging technology," Appl. Opt. 57, 6772-6780 (2018). https://doi.org/10.1364/AO.57.006772
- C. M. Chen, R. M. Kwasnicki, V. F. Curto, G.-Z. Yang, and B. P. L. Lo, "Tissue oxygenation sensor and an active in vitro phantom for sensor validation," IEEE Sens. J. 19, 8233-8240 (2019). https://doi.org/10.1109/JSEN.2019.2917122
- N. Tomm, L. Ahnen, H. Isler, S. Kleiser, T. Karen, D. Ostojic, M. Wolf, and F. Scholkmann, "Characterization of the optical properties of color pastes for the design of optical phantoms mimicking biological tissue," J. Biophotonics 12, e201800300 (2019).
- H. Assadi, V. Demidov, R. Karshafian, A. Douplik, and I. A. Vitkin, "Microvascular contrast enhancement in optical coherence tomography using microbubbles," J. Biomed. Opt. 21, 076014 (2016).
- P. Stohanzlova and R. Kolar, "Tissue perfusion modelling in optical coherence tomography," Biomed. Eng. Online 16, 27 (2017).
- S. Song, Z. Huang, T.-M. Nguyen, E. Y. Wong, B. Arnal, M. O'Donnell, and R. K. Wang, "Shear modulus imaging by direct visualization of propagating shear waves with phase-sensitive optical coherence tomography," J. Biomed. Opt. 18, 121509 (2013).
- M. Razani, T. W. H. Luk, A. Mariampillai, P. Siegler, T.-R. Kiehl, M. C. Kolios, and V. X. D. Yang, "Optical coherence tomography detection of shear wave propagation in inhomogeneous tissue equivalent phantoms and ex-vivo carotid artery samples," Biomed. Opt. Express 5, 895-906 (2014). https://doi.org/10.1364/BOE.5.000895
- P. Jelvehgaran, T. Alderliesten, J. J. Weda, M. de Bruin, D. J. Faber, M. C. Hulshof, T. G. van Leeuwen, M. van Herk, and J. F. de Boer, "Visibility of fiducial markers used for image-guided radiation therapy on optical coherence tomography for registration with CT: An esophageal phantom study," Med. Phys. 44, 6570-6582 (2017). https://doi.org/10.1002/mp.12624
- T. S. Rowe and R. J. Zawadzki, "Development of a corneal tissue phantom for anterior chamber optical coherence tomography (AC-OCT)," Proc. SPIE 8583, 85830I (2013).
- A. Corcoran, G. Muyo, J. van Hemert, A. Gorman, and A. R. Harvey, "Application of a wide-field phantom eye for optical coherence tomography and reflectance imaging," J. Mod. Opt. 62, 1828-1838 (2015). https://doi.org/10.1080/09500340.2015.1045309
- J. Baxi, W. Calhoun, Y. J. Sepah, D. X. Hammer, I. Ilev, T. Joshua Pfefer, Q. D. Nguyen, and A. Agrawal, "Retina-simulating phantom for optical coherence tomography," J. Biomed. Opt. 19, 021106 (2014).
- G. C. F. Lee, G. T. Smith, M. Agrawal, T. Leng, and A. K. Ellerbee, "Fabrication of healthy and disease-mimicking retinal phantoms with tapered foveal pits for optical coherence tomography," J. Biomed. Opt. 20, 085004 (2015).
- A. Agrawal, J. Baxi, W. Calhoun, C.-L. Chen, H. Ishikawa, J. S. Schuman, G. Wollstein, and D. X. Hammer, "Optic nerve head measurements with optical coherence tomography: A phantom-based study reveals differences among clinical devices," Investig. Ophthalmol. Vis. Sci. 57, OCT413-OCT420 (2016). https://doi.org/10.1167/iovs.15-18738
- A. C. Lamont, M. A. Restaino, A. T. Alsharhan, Z. Liu, D. X. Hammer, R. D. Sochol, and A. Agrawal, "Direct laser writing of a titanium dioxide-laden retinal cone phantom for adaptive optics-optical coherence tomography," Opt. Mater. Express 10, 2757-2767 (2020). https://doi.org/10.1364/OME.400450
- G. T. Smith, K. L. Lurie, S. A. Khan, J. C. Liao, and A. K. Ellerbee, "Multilayered disease-mimicking bladder phantom with realistic surface topology for optical coherence tomography," Proc. SPIE 8945, 89450E (2014).
- K. L. Lurie, G. T. Smith, S. A. Khan, J. C. Liao, and A. K. Ellerbee, "Three-dimensional, distendable bladder phantom for optical coherence tomography and white light cystoscopy," J. Biomed. Opt. 19, 036009 (2014).
- N. Zulina, O. Caravaca, G. Liao, S. Gravelyn, M. Schmitt, K. Badu, L. Heroin, and M. J. Gora, "Colon phantoms with cancer lesions for endoscopic characterization with optical coherence tomography," Biomed. Opt. Express 12, 955-968 (2021). https://doi.org/10.1364/BOE.402081
- N. R. Munce, G. A. Wright, A. Mariampillai, B. A. Standish, M. K. K. Leung, L. Tan, K. Lee, B. K. Courtney, A. A. Teitelbaum, B. H. Strauss, I. A. Vitkin, and V. X. D. Yang, "Doppler optical coherence tomography for interventional cardiovascular guidance: In vivo feasibility and forward-viewing probe flow phantom demonstration," J. Biomed. Opt. 15, 011103 (2010).
- C.-E. Bisaillon, M. L. Dufour, and G. Lamouche, "Artery phantoms for intravascular optical coherence tomography: Healthy arteries," Biomed. Opt. Express 2, 2599-2613 (2011). https://doi.org/10.1364/BOE.2.002599
- C.-E. Bisaillon and G. Lamouche, "Artery phantoms for intravascular optical coherence tomography: Diseased arteries," J. Biomed. Opt. 18, 096010 (2013).
- L. B. Christie, W. Zheng, W. Johnson, E. K. Marecki, J. Heidrich, J. Xia, and K. W. Oh, "Review of imaging test phantoms," J. Biomed. Opt. 28, 080903 (2023).
- S. J. Arconada-Alvarez, J. E. Lemaster, J. Wang, and J. V. Jokerst, "The development and characterization of a novel yet simple 3D printed tool to facilitate phantom imaging of photoacoustic contrast agents," Photoacoustics 15, 17-24 (2017).
- E. Cuche, F. Bevilacqua, and C. Depeursinge, "Digital holography for quantitative phase-contrast imaging," Opt. Lett. 24, 291-293 (1999). https://doi.org/10.1364/OL.24.000291
- J.-W. Kang and C.-K. Hong, "Three dimensional shape measurement of a micro Fresnel lens with in-line phase-shifting digital holographic microscopy," J. Opt. Soc. Korea 10, 178- 183 (2006). https://doi.org/10.3807/JOSK.2006.10.4.178
- A. Fiore, C. Bevilacqua, and G. Scarcelli, "Direct three-dimensional measurement of refractive index via dual photonphonon Scattering," Phys. Rev. Lett. 122, 103901 (2019).
- K. Zhang, S. Sasaki, S. Choi, S. Luo, T. Suzuki, and J. Pu, "Measurement of phase refractive index directly from phase distributions detected with a spectrally resolved interferometer," Appl. Opt. 60, 10009-10015 (2021). https://doi.org/10.1364/AO.438267
- W. Krauze, A. Kus, M. Ziemczonok, M. Haimowitz, S. Chowdhury, and M. Kujawinska, "3D scattering microphantom sample to assess quantitative accuracy in tomographic phase microscopy techniques," Sci. Rep. 12, 19586 (2022).
- I. Shevkunov, M. Ziemczonok, M. Kujawinska, and K. Egiazarian, "Complex-domain SVD- and sparsity-based denoising for optical diffraction tomography," Opt. Laser Eng. 159, 107228 (2022).
- L. Hacker, H. Wabnitz, A. Pifferi, T. J. Pfefer, B. W. Pogue, and S. E. Bohndiek, "Criteria for the design of tissue-mimicking phantoms for the standardization of biophotonic instrumentation," Nat. Biomed. Eng. 6, 541-558 (2022). https://doi.org/10.1038/s41551-022-00890-6
- L. Cortese, M. Zanoletti, U. Karadeniz, M. Paglizzi, M. A. Yaqub, D. R. Busch, J. Mesquida, and T. Durduran, "Performance assessment of a commercial continuous-wave nearinfrared spectroscopy tissue oximeter for suitability for use in an international, multi-center clinical trial," Sensors 21, 6957 (2021).
- I. Fredriksson, R. B. Saager, A. J. Burkin, and T. Stromberg, "Evaluation of a pointwise microcirculation assessment method using liquid and multilayered tissue simulating phantoms," J. Biomed. Opt. 22, 115004 (2017).
- M. Majedy, R. B. Saager, T. Stromberg, M. Larsson, and E. G. Salerud, "Spectral characterization of liquid hemoglobin phantoms with varying oxygenation states," J. Biomed. Opt. 27, 074708 (2022).
- H. Chen, G. Liu, S. Zhang, S. Shen, Y. Luo, J. Li, C. J. Roberts, M. Sun, and R. X. Xu, "Fundus-simulating phantom for calibration of retinal vessel oximetry devices," Appl. Opt. 58, 3877-3885 (2019). https://doi.org/10.1364/AO.58.003877
- N. Nasseri, S. Kleiser, D. Ostojic, T. Karen, and M. Wolf, "Quantifying the effect of adipose tissue in muscle oximetry by near infrared spectroscopy," Biomed. Opt. Express 7, 4605-4619 (2016). https://doi.org/10.1364/BOE.7.004605
- D. J. Mordant, I. Al-Abboud, G. Muyo, A. Gorman, A. Sallam, P. Rodmell, J. Crowe, S. Morgan, P. Ritchie, A. R. Harvey, and A. I. McNaught, "Validation of human whole blood oximetry, using a hyperspectral fundus camera with a model eye," Investig. Ophthalmol. Vis. Sci. 52, 2851-2859 (2011). https://doi.org/10.1167/iovs.10-6217
- A. Afshari, R. B. Saager, D. Burgos, W. C. Vogt, J. Wang, G. Mendoza, S. Weininger, K.-B. Sung, A. J. Durkin, and T. J. Pfefer, "Evaluation of the robustness of cerebral oximetry to variations in skin pigmentation using a tissue-simulating phantom," Biomed. Opt. Express 13, 2909-2928 (2022). https://doi.org/10.1364/BOE.454020
- A. J. Rodriguez, S. Vasudevan, M. Farahmand, S. Weininger, W. C. Vogt, C. G. Scully, J. Ramella-Roman, and T. J. Pfefer, "Tissue mimicking materials and finger phantom design for pulse oximetry," Biomed. Opt. Express 15, 2308-2327 (2024). https://doi.org/10.1364/BOE.518967
- T. He, C. Guo, H. Liu, and L. Jiang, "A venipuncture robot with decoupled position and attitude guided by near-infrared vision and force feedback," Int. J. Med. Robot. 19, e2512 (2023).
- J. Huang, S. Jiang, H. Yang, R. Czuma, Y. Yang, F. A. Kozel, and H. Jiang, "Portable diffuse optical tomography for three-dimensional functional neuroimaging in the hospital," Photonics 11, 238 (2024).
- N. Otic, J. Sunwoo, Y. Huang, A. Martin, M. B. Robinson, B. Zimmermann, S. Carp, T. Inder, M. El-Dib, M. A. Franceschini, and M. Renna, "Multi-wavelength multi-distance diffuse correlation spectroscopy system for assessment of premature infants' cerebral hemodynamics," Biomed. Opt. Express 15, 1959-1975 (2024).
- S. Kleiser, D. Ostojic, B. Andresen, N. Jasseri, H. Isler, F. Scholkmann, T. Karen, G. Greisen, and M. Wolf, "Comparison of tissue oximeters on a liquid phantom with adjustable optical properties: An extension," Biomed. Opt. Express 9, 88-101 (2018).
- L. E. MacKenzie, A. R. Harvey, and A. I. McNaught, "Spectroscopic oximetry in the eye: A review," Expert Rev. Ophthalmol. 12, 345-356 (2017). https://doi.org/10.1080/17469899.2017.1318067