DOI QR코드

DOI QR Code

Performance Evaluation of the Roche Cobas 5800 HBV and HCV Tests: Comparison of the 200 and 500 μL Protocols

  • Seri Jeong (Department of Laboratory Medicine, Hallym University Kangnam Sacred Heart Hospital, Hallym University College of Medicine) ;
  • Su Kyung Lee (Department of Laboratory Medicine, Hallym University Dongtan Sacred Heart Hospital, Hallym University College of Medicine) ;
  • Eun-Jung Cho (Department of Laboratory Medicine, Hallym University Dongtan Sacred Heart Hospital, Hallym University College of Medicine) ;
  • Han-Sung Kim (Department of Laboratory Medicine, Hallym University Sacred Heart Hospital, Hallym University College of Medicine) ;
  • Young Kyung Lee (Department of Laboratory Medicine, Hallym University Sacred Heart Hospital, Hallym University College of Medicine) ;
  • Jae-Seok Kim (Department of Laboratory Medicine, Kangdong Sacred Heart Hospital, Hallym University College of Medicine) ;
  • Wonkeun Song (Department of Laboratory Medicine, Hallym University Kangnam Sacred Heart Hospital, Hallym University College of Medicine) ;
  • Hyun Soo Kim (Department of Laboratory Medicine, Hallym University Dongtan Sacred Heart Hospital, Hallym University College of Medicine)
  • Received : 2023.08.02
  • Accepted : 2023.11.29
  • Published : 2024.05.01

Abstract

Background: Clinical management of patients infected with hepatitis B virus (HBV) or hepatitis C virus (HCV) relies on the viral load (VL). The Cobas 5800 system (Roche Diagnostics) can determine VLs in 200 and 500 μL samples, but the performance of each protocol has not been compared. We evaluated the performance of both protocols for the HBV and HCV tests. Methods: Precision and linearity were verified using commercial panels. Probit analyses were used to determine limits of detection (LoDs). The results obtained with 336 samples were compared using the 200 and 500 μL protocols. Data from 6,737 retrospective HBV and 768 HCV samples were compared to estimate the effects of the different LoDs on the diagnostic results of the protocols. Correlations between protocols were tested with Spearman's rank correlation coefficients (rho). Results: The precision and linearity of both protocols were verified. The LoDs for the 200 and 500 μL protocols were 6.5 and 2.7 IU/mL for HBV and 29.7 and 8.2 IU/mL for HCV, respectively. The agreement between the protocols ranged from 0.8 to 1.0. The results obtained with the HBV and HCV tests showed a strong correlation (rho=0.994). Only 0.4% of HBV and 0.4% of HCV test results were affected by the LoDs of the 200 μL protocol. Conclusions: The Cobas 5800 200 and 500 μL protocols for the HBV DNA and HCV RNA tests demonstrated excellent performance. These findings establish the 200 μL protocol as a new option for low-volume samples, especially for pediatric and difficult-to-bleed patients.

Keywords

Acknowledgement

The authors appreciate the staff at Roche Diagnostics for providing reagents and technical support. We also appreciate the Biobank at Chung-Ang University.

References

  1. World Health Organization. Guidelines on hepatitis B and C testing. http://apps.who.int/iris/bitstream/handle/10665/254621/9789241549981-eng.pdf (Updated on Feb 2017).
  2. American Association for the Study of Liver Diseases and Infectious Diseases Society of America. HCV guidance: recommendations for testing, managing, and treating hepatitis C. https://www.hcvguidelines.org/sites/default/files/full-guidance-pdf/AASLD-IDSA_HCVGuidance_October_05_2021.pdf (Updated on Oct 2021).
  3. European Association for the Study of the Liver. EASL 2017 Clinical Practice Guidelines on the management of hepatitis B virus infection. J Hepatol 2017;67:370-98. https://doi.org/10.1016/j.jhep.2017.03.021
  4. European Association for the Study of the Liver. EASL recommendations on treatment of hepatitis C 2018. J Hepatol 2018;69:461-511. https://doi.org/10.1016/j.jhep.2018.03.026
  5. Terrault NA, Lok ASF, McMahon BJ, Chang KM, Hwang JP, Jonas MM, et al. Update on prevention, diagnosis, and treatment of chronic hepatitis B: AASLD 2018 hepatitis B guidance. Hepatology 2018;67:1560-99. https://doi.org/10.1002/hep.29800
  6. Hur M, Park M, Moon HW, Choe WH, Lee CH. Comparison of non-invasive clinical algorithms for liver fibrosis in patients with chronic hepatitis B to reduce the need for liver biopsy: application of enhanced liver fibrosis and Mac-2 binding protein glycosylation isomer. Ann Lab Med 2022;42:249-57. https://doi.org/10.3343/alm.2022.42.2.249
  7. Andersson KL and Chung RT. Monitoring during and after antiviral therapy for hepatitis B. Hepatology 2009;49(S5):S166-73. https://doi.org/10.1002/hep.22899
  8. Braun P, Delgado R, Drago M, Fanti D, Fleury H, Izopet J, et al. A European multicientre study on the comparison of HBV viral loads between VERIS HBV assay and Roche COBAS® TAQMAN® HBV test, Abbott Real Time HBV assay, Siemens VERSANT HBV assay, and Qiagen Artus HBVRG kit. J Clin Virol 2017;95:76-83. https://doi.org/10.1016/j.jcv.2017.08.015
  9. Park Y, Roh J, Kim S. Performance evaluation of the Aptima assays in comparison with the cobas 6800 Assays for the detection of HIV-1, HBV, and HCV in clinical samples. Ann Lab Med 2022;42:447-56. https://doi.org/10.3343/alm.2022.42.4.447
  10. Tschäpe J, Cobernuss-Rahn A, Boyle S, Parkin N, LaBrot B, Aslam S, et al. Multisite performance evaluation of the Cobas 5800 System and comparison to the Cobas 6800/8800 systems for quantitative measurement of HBV, HCV, and HIV-1 viral load. Microbiol Spectr 2022;10:e0312522. https://doi.org/10.1128/spectrum.03125-22
  11. Tan NK, Carrington D, Pope CF. Verification of the Roche Cobas® 6800 PCR 200 µl and 500 µl protocols for the quantification of HIV-1 RNA, HBV DNA and HCV RNA and evaluation with COBAS® Ampliprep/COBAS®TaqMan® assays. J Med Microbiol 2018;67:1711-7. https://doi.org/10.1099/jmm.0.000838
  12. McHugh ML. Interrater reliability: the kappa statistic. Biochem Med (Zagreb) 2012;22:276-82. https://doi.org/10.11613/BM.2012.031
  13. Schober P, Boer C, Schwarte LA. Correlation coefficients: appropriate use and interpretation. Anesth Analg 2018;126:1763-8. https://doi.org/10.1213/ANE.0000000000002864
  14. European Association for the Study of the Liver. EASL clinical practice guidelines: management of chronic hepatitis B virus infection. J Hepatol 2012;57:167-85. https://doi.org/10.1016/j.jhep.2012.02.010
  15. Terrault NA, Bzowej NH, Chang KM, Hwang JP, Jonas MM, Murad MH, et al. AASLD guidelines for treatment of chronic hepatitis B. Hepatology 2016;63:261-83. https://doi.org/10.1002/hep.28156
  16. Sidharthan S, Kohli A, Sims Z, Nelson A, Osinusi A, Masur H, et al. Utility of hepatitis C viral load monitoring on direct-acting antiviral therapy. Clin Infect Dis 2015;60:1743-51. https://doi.org/10.1093/cid/civ170
  17. Wirden M, Larrouy L, Mahjoub N, Todesco E, Damond F, Delagreverie H, et al. Multicenter comparison of the new Cobas 6800 system with Cobas Ampliprep/Cobas TaqMan and Abbott RealTime for the quantification of HIV, HBV and HCV viral load. J Clin Virol 2017;96:49-53. https://doi.org/10.1016/j.jcv.2017.09.007
  18. Baylis SA, Hanschmann KO, Schnierle BS, Trösemeier JH, Blümel J; Zika Virus Collaborative Study Group. Harmonization of nucleic acid testing for Zika virus: development of the 1st World Health Organization International Standard. Transfusion 2017;57:748-61. https://doi.org/10.1111/trf.14026
  19. Baylis SA, Wallace P, McCulloch E, Niesters HGM, Nübling CM. Standardization of nucleic acid tests: the approach of the World Health Organization. J Clin Microbiol 2019;57:e01056-18. https://doi.org/10.1128/JCM.01056-18
  20. Scholtès C, Hamilton AT, Plissonnier ML, Charre C, Scott B, Wang L, et al. Performance of the Cobas® HBV RNA automated investigational assay for the detection and quantification of circulating HBV RNA in chronic HBV patients. J Clin Virol 2022;150-151:105150. https://doi.org/10.1016/j.jcv.2022.105150
  21. Caliendo AM, Valsamakis A, Bremer JW, Ferreira-Gonzalez A, Granger S, Sabatini L, et al. Multilaboratory evaluation of real-time PCR tests for hepatitis B virus DNA quantification. J Clin Microbiol 2011;49:2854-8. https://doi.org/10.1128/JCM.00471-11
  22. Han MS, Park Y, Nah H, Kim HS. Comparison of the Qiagen Artus HBV QS-RGQ assay with the Roche COBAS AmpliPrep/COBAS TaqMan HBV assay for quantifying viral DNA in sera of chronic hepatitis B patients. Ann Lab Med 2017;37:248-53. https://doi.org/10.3343/alm.2017.37.3.248
  23. Ismail AM, Sivakumar J, Anantharam R, Dayalan S, Samuel P, Fletcher GJ, et al. Performance characteristics and comparison of Abbott and Artus real-time systems for hepatitis B virus DNA quantification. J Clin Microbiol 2011;49:3215-21. https://doi.org/10.1128/JCM.00915-11
  24. Yeh ML, Huang CF, Huang CI, Liu SF, Yang HL, Hsieh MY, et al. Abbott RealTime HBV assay is more sensitive in detection of low viral load and little impacted by drug resistant mutation in chronic hepatitis B patients under nucleot(s)ide analogues therapy. PLoS One 2014;9:e101790. https://doi.org/10.1371/journal.pone.0101790
  25. Vermehren J, Colucci G, Gohl P, Hamdi N, Abdelaziz AI, Karey U, et al. Development of a second version of the Cobas AmpliPrep/Cobas TaqMan hepatitis C virus quantitative test with improved genotype inclusivity. J Clin Microbiol 2011;49:3309-15. https://doi.org/10.1128/JCM.00602-11