과제정보
This research was supported by regional leading research center (RLRC) program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education (NRF-2021R1|1A1A01059845) and Korea Institute of Energy Technology Evaluation and Planning (KETEP) grant funded by the Korea Government (MOTIE) (No. 20227410100040).
참고문헌
- McKenna MG, Chen XG, Altschuler MD, Bloch P. Calculation of the dose in the build-up region for high energy photon beam. Treatment planning when beam spoilers are employed. Radiother Oncol. 1995;34:63-68. https://doi.org/10.1016/0167-8140(95)01504-A
- Ishmael Parsai E, Shvydka D, Pearson D, Gopalakrishnan M, Feldmeier JJ. Surface and build-up region dose analysis for clinical radiotherapy photon beams. Appl Radiat Isot. 2008;66:1438-1442. https://doi.org/10.1016/j.apradiso.2008.02.089
- Butson MJ, Cheung T, Yu P, Metcalfe P. Effects on skin dose from unwanted air gaps under bolus in photon beam radiotherapy. Radiat Meas. 2000;32:201-204. https://doi.org/10.1016/S1350-4487(99)00276-0
- Khan Y, Villarreal-Barajas JE, Udowicz M, Sinha R, Muhammad W, Abbasi AN, et al. Clinical and dosimetric implications of air gaps between bolus and skin surface during radiation therapy. J Cancer Ther. 2013;4:1251-1255. https://doi.org/10.4236/jct.2013.47147
- Lobo D, Banerjee S, Srinivas C, Ravichandran R, Putha SK, Prakash Saxena PU, et al. Influence of air gap under bolus in the dosimetry of a clinical 6 MV photon beam. J Med Phys. 2020;45:175-181. https://doi.org/10.4103/jmp.JMP_53_20
- Wang KM, Rickards AJ, Bingham T, Tward JD, Price RG. Technical note: evaluation of a silicone-based custom bolus for radiation therapy of a superficial pelvic tumor. J Appl Clin Med Phys. 2022;23:e13538.
- Wang X, Wang X, Xiang Z, Zeng Y, Liu F, Shao B, et al. The clinical application of 3D-printed boluses in superficial tumor radiotherapy. Front Oncol. 2021;11:698773.
- Burleson S, Baker J, Hsia AT, Xu Z. Use of 3D printers to create a patient-specific 3D bolus for external beam therapy. J Appl Clin Med Phys. 2015;16:5247.
- Park JM, Son J, An HJ, Kim JH, Wu HG, Kim JI. Bio-compatible patient-specific elastic bolus for clinical implementation. Phys Med Biol. 2019;64:105006.
- Almond PR, Biggs PJ, Coursey BM, Hanson WF, Huq MS, Nath R, et al. AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams. Med Phys. 1999;26:1847-1870. https://doi.org/10.1118/1.598691
- McEwen M, DeWerd L, Ibbott G, Followill D, Rogers DW, Seltzer S, et al. Addendum to the AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon beams. Med Phys. 2014;41:041501.
- Son J, Jung S, Park JM, Choi CH, Kim JI. Assessing commercial CLEANBOLUS based on silicone for clinical use. Prog Med Phys. 2021;32:159-164. https://doi.org/10.14316/pmp.2021.32.4.159