Abstract

Since atypical high-rise buildings are vulnerable to gravity loads and seismic loads, various structural systems must be applied to ensure the stability of the structure. In this study, the authors selected a 60-story twisted-shaped structure among atypical high-rise structures as an analytical model to investigate its structural behavior concerning the outrigger system. The structural analyses were performed varying the number of installed layers and the arrangement of the outrigger system, as well as the placement of the mega column, as design variables. The analysis revealed that the most effective position for the outrigger was 0.455H from the top layer, consistent with previous studies. Additionally, connecting outriggers and mega columns significantly reduced the displacement response of the model. From an economic standpoint, it is deemed efficient to connect and install outriggers and mega columns at the structure's ends.

Keywords

Acknowledgement

본 논문은 2024년도 정부(과학기술정보통신부)의 재원으로 한국연구재단의 지원을 받아 수행된 연구임 (NRF-2023R1A2C1002542)

References

  1. Lee, D. H., Kim, H. S., & Kang, J. W., "Dynamic Response Analysis of Twisted High-rise Structures by Plane Rotation Angle", Journal of Korean Association for Spatial Structures, Vol.21, No.1, pp.105~112, 2021, DOI:https://doi.org/10.9712/KASS.2021.21.1.105
  2. Chung, K. R., "Stuctural System for Irregular Shaped Tall Buildings", Review of Architecture and Building Science, Vol.52, No.4, pp.59~62, 2008
  3. Taranath, B. S., "Steel, Concrete and Composite Design of Tall Building", 2nd ed., McGraw-Hill, pp.445~459, 1997
  4. McNabb, J. W. & Muvdi, B. B., "Drift Reduction Factors for Belted High-Rise Structures", Engineering Journal-American Institute of Steel Construction, Vol.12, No.3, pp.88~91, 1975
  5. Jung, D. J., Kim, I. Z., Lee, Y. S., & Kim, G. S., "The Approximate Analysis of Outrigger-Braced Structures subjected to Linearly Varying Lateral Lading", Journal of the Architectural Institute of Korea, Vol.12, No.7, pp.271~278, 1996
  6. Kim, H. K., "Structural Analysis on Investigation of Optimum Location of Outrigger System in High-Rise Building", Journal of the Regional Association of Architectural Institute of Korea, Vol.15, No.4, pp.85~92, 2013
  7. Kim, H. K., "Comparative Analysis on Influence of Structure Elements on Optimal Location of One-Outrigger System", Journal of The Korea Institute for Structural Maintenance and Inspection, Vol.19, No.2, pp.22~32, 2015, DOI:https://doi.org/10.11112/jksmi.2015.19.2.022
  8. Jung, E. Y., & Park, S. S., "Study on the Optimal Cross Section Design of the High-rise Buildings Composed of Mega Column - Outrigger - Shear Walls", Jounal of the Regional Association of Architectural Institute of Korea. Vol.17, No.6, pp.135~142, 2015
  9. Youn, W. S., Lee, D. H., Cho, C. H., Kim, E. S., Lee, D. C., & Kim, J. H., "Seismic Performance Evaluation of Complex-Shaped Tall Buildings by Lateral Resisting Systems", Journal of the Computational Structural Engineering Institute of Korea, Vol.25, No.6, pp.513~523, 2012, DOI:https://doi.org/10.7734/COSEIK.2012.25.6.513
  10. Moon, K. S., "Outrigger Systems for Structutal Design of Complex-Shaped Tall Buildings", International Journal of HighRise Buildings, Vol 5, No 1, pp.13~20. 2016, DOI:https://doi.org/10.21022/IJHRB.2016.5.1.13
  11. Lee, D. H., Kim, H. S. & Kang, J. W., "Analysis of the Static Characteristics of High-Rise Structure With Twisted Shape", Journal of the Korean Association for Spatial Structure, Vol.20 No.4, pp.93~100, 2020, DOI:https://doi.org/10.9712/KASS.2020.20.4.93
  12. Architectural Institute of Korea, Korean Design Standard (KDS 41 17 00:2022), 2022.