DOI QR코드

DOI QR Code

Accuracy of orthodontic movements with 3D printed aligners: A prospective observational pilot study

  • 투고 : 2023.12.15
  • 심사 : 2024.04.04
  • 발행 : 2024.05.25

초록

Objective: Owing to the availability of 3D software, scanners, and printers, clinicians are encouraged to produce in-office aligners. Recently, a new direct-printing resin (Tera Harz TC-85DAC) has been introduced. Studies on its mechanical characteristics and biological effects have been published; however, evidence on its efficacy in orthodontic treatment remains scarce. This pilot study aimed to investigate the accuracy of teeth movement achieved with direct-printed aligners. Methods: Seventeen patients (eight males and nine females) with a mean age of 27.67 ± 8.95 years, presenting with dental rotations < 30° and spaces/crowding < 5 mm, were recruited for this study. The teeth movement was planned starting from a T0 digital dental cast. The 3D direct-printed aligners were produced using Tera Harz TC-85DAC resin. Once the orthodontic treatment was completed, a final digital cast was obtained (T1). The planned teeth positions were then superimposed onto the T0 and T1 digital models. The differences between the programmed movements and the achieved overall torque, tip, rotation, and transverse dimensions were assessed using the paired t test or Wilcoxon's signed rank test. Results: The overall accuracies for torque, tip, and rotation were 67.6%, 64.2%, and 72.0%, respectively. The accuracy of the change in transverse diameter was 99.6%. Conclusions: Within the limits of the present pilot study (difficulties with abnormally shaped teeth and use of attachments), it can be concluded that 3D printed aligners can be successfully printed in-house and utilized for mildly crowded cases, with a comparable accuracy of tooth movement to that of other aligners.

키워드

참고문헌

  1. Bilello G, Fazio M, Amato E, Crivello L, Galvano A, Curro G. Accuracy evaluation of orthodontic movements with aligners: a prospective observational study. Prog Orthod 2022;23:12. https://doi.org/10.1186/s40510-022-00406-7 
  2. Ballard ML. Asymmetry in tooth size: a factor in the etiology, diagnosis and treatment of malocclusion. Angle Orthod 1944;14:67-70. https://meridian.allenpress.com/angle-orthodontist/article/14/3/67/54809/Asymmetry-in-Tooth-Size-A-Factor-in-the-Etiology 
  3. Sheridan JJ. Air-rotor stripping. J Clin Orthod 1985;19:43-59. https://pubmed.ncbi.nlm.nih.gov/3882756/ 
  4. Kesling HD. The philosophy of tooth positioning appliance. Am J Orthod Oral Surg 1945;31:297-304. https://doi.org/10.1016/0096-6347(45)90101-3 
  5. Papadimitriou A, Mousoulea S, Gkantidis N, Kloukos D. Clinical effectiveness of Invisalign® orthodontic treatment: a systematic review. Prog Orthod 2018;19:37. https://doi.org/10.1186/s40510-018-0235-z 
  6. Rossini G, Parrini S, Castroflorio T, Deregibus A, Debernardi CL. Efficacy of clear aligners in controlling orthodontic tooth movement: a systematic review. Angle Orthod 2015;85:881-9. https://doi.org/10.2319/061614-436.1 
  7. Jaber ST, Hajeer MY, Burhan AS. The effectiveness of in-house clear aligners and traditional fixed appliances in achieving good occlusion in complex orthodontic cases: a randomized control clinical trial. Cureus 2022;14:e30147. https://doi.org/10.7759/cureus.30147 
  8. Peter E, J M, Ani George S. Are clear aligners environment friendly? Am J Orthod Dentofacial Orthop 2022;161:619-20. https://doi.org/10.1016/j.ajodo.2021.12.012 
  9. Can E, Panayi N, Polychronis G, Papageorgiou SN, Zinelis S, Eliades G, et al. In-house 3D-printed aligners: effect of in vivo ageing on mechanical properties. Eur J Orthod 2022;44:51-5. https://doi.org/10.1093/ejo/cjab022 
  10. Hertan E, McCray J, Bankhead B, Kim KB. Force profile assessment of direct-printed aligners versus thermoformed aligners and the effects of nonengaged surface patterns. Prog Orthod 2022;23:49. https://doi.org/10.1186/s40510-022-00443-2 
  11. Lee SY, Kim H, Kim HJ, Chung CJ, Choi YJ, Kim SJ, et al. Thermo-mechanical properties of 3D printed photocurable shape memory resin for clear aligners. Sci Rep 2022;12:6246. https://doi.org/10.1038/s41598-022-09831-4 
  12. Pratsinis H, Papageorgiou SN, Panayi N, Iliadi A, Eliades T, Kletsas D. Cytotoxicity and estrogenicity of a novel 3-dimensional printed orthodontic aligner. Am J Orthod Dentofacial Orthop 2022;162:e116-22. https://doi.org/10.1016/j.ajodo.2022.06.014 
  13. Huanca Ghislanzoni LT, Lineberger M, Cevidanes LH, Mapelli A, Sforza C, McNamara JA Jr. Evaluation of tip and torque on virtual study models: a validation study. Prog Orthod 2013;14:19. https://doi.org/10.1186/2196-1042-14-19 
  14. Vasilakos G, Schilling R, Halazonetis D, Gkantidis N. Assessment of different techniques for 3D superimposition of serial digital maxillary dental casts on palatal structures. Sci Rep 2017;7:5838. https://doi.org/10.1038/s41598-017-06013-5 
  15. Santos RF, Santos BFO, Fernandes VM, Caldas LD, Baldo TO, Dominguez GC. Validity and reliability of a trigonometry-based method for the measurement of tooth movement on digital models. Dental Press J Orthod 2021;26:e2119148. https://doi.org/10.1590/2177-6709.26.3.e2119148.oar 
  16. Castroflorio T, Sedran A, Parrini S, Garino F, Reverdito M, Capuozzo R, et al. Predictability of orthodontic tooth movement with aligners: effect of treatment design. Prog Orthod 2023;24:2. https://doi.org/10.1186/s40510-022-00453-0 Erratum in: Prog Orthod 2023;24:47. https://doi.org/10.1186/s40510-023-00499-8 
  17. Willi A, Patcas R, Zervou SK, Panayi N, Schatzle M, Eliades G, et al. Leaching from a 3D-printed aligner resin. Eur J Orthod 2023;45:244-9. https://doi.org/10.1093/ejo/cjac056 
  18. Al-Dboush RE, Al-Zawawi E, El-Bialy T. Do orthodontic treatments using fixed appliances and clear aligner achieve comparable quality of occlusal contacts? Evid Based Dent 2022;23:160-1. https://doi.org/10.1038/s41432-022-0844-8 
  19. Lombardo L, Arreghini A, Ramina F, Huanca Ghislanzoni LT, Siciliani G. Predictability of orthodontic movement with orthodontic aligners: a retrospective study. Prog Orthod 2017;18:35. https://doi.org/10.1186/s40510-017-0190-0 
  20. Nguyen CV, Chen J. Three-dimensional superimposition tool. In: Tuncay OC, ed. The Invisalign system. New Malden: Quintessence Publishing Company, Ltd.; 2006. p. 12-32. https://www.quintessence-publishing.com/gbr/en/product/the-invisalign-system 
  21. Grunheid T, Loh C, Larson BE. How accurate is Invisalign in nonextraction cases? Are predicted tooth positions achieved? Angle Orthod 2017;87:809-15. https://doi.org/10.2319/022717-147.1 
  22. Kravitz ND, Kusnoto B, Agran B, Viana G. Influence of attachments and interproximal reduction on the accuracy of canine rotation with Invisalign. A prospective clinical study. Angle Orthod 2008;78:682-7. https://doi.org/10.2319/0003-3219(2008)078[0682:IOAAIR]2.0.CO;2 
  23. Simon M, Keilig L, Schwarze J, Jung BA, Bourauel C. Treatment outcome and efficacy of an aligner technique--regarding incisor torque, premolar derotation and molar distalization. BMC Oral Health 2014;14:68. https://doi.org/10.1186/1472-6831-14-68 
  24. Sachdev S, Tantidhnazet S, Saengfai NN. Accuracy of tooth movement with in-house clear aligners. J World Fed Orthod 2021;10:177-82. https://doi.org/10.1016/j.ejwf.2021.08.003 
  25. Zinelis S, Panayi N, Polychronis G, Papageorgiou SN, Eliades T. Comparative analysis of mechanical properties of orthodontic aligners produced by different contemporary 3D printers. Orthod Craniofac Res 2022;25:336-41. https://doi.org/10.1111/ocr.12537