DOI QR코드

DOI QR Code

Application of analytic hierarchy process technique for selecting a hydrothermal energy site

수열에너지 입지 선정을 위한 계층화분석법의 적용

  • Joohyun Ahn (Department Waterfront City Business, Korea Water Resources Corporation) ;
  • Suwan Park (Department of Civil and Environmental Engineering, Pusan National University) ;
  • Changhyun Oh (Department of Civil and Environmental Engineering, Pusan National University)
  • 안주현 (한국수자원공사 수변사업처) ;
  • 박수완 (부산대학교 사회환경시스템공학과) ;
  • 오창현 (부산대학교 사회환경시스템공학과)
  • Received : 2024.01.26
  • Accepted : 2024.03.14
  • Published : 2024.04.15

Abstract

In this study, an evaluation system that can be used to evaluate the feasibility of developing and supplying hydrothermal energy for the operation of large-scale complex facilities was developed. To this end, this study derived factors to be considered when selecting a location for the use of hydrothermal energy using raw water from multi-purpose dams and regional water supply systems through literature survey and expert interviews. The evaluation indicators derived from this study are divided into four sectors: hydrothermal energy utilization factors, location factors, planning factors, and disaster safety factors, and are composed of 10 mid-level indicators and 34 detailed planning indicators. The relative importance of all factors was derived using the Analytic Hierarchy Process (AHP) technique, and the developed evaluation indicators and relative importance were applied to four multi-purpose dam regions in the country. As a result, it was found that in the development and use of hydrothermal energy utilizing regional raw water supply line the urban planning conditions of the supply site can have a greater impact on the location selection results than the hydrothermal energy development itself. Due to the characteristics of the evaluation indicators developed in this study and their nature as comprehensive indicators, it is believed that the results should be applied to determine the overall adequacy of site selection in the early stages of hydrothermal energy development. In the future, it is believed that it will be necessary to analyze the problems in supplying and operating hydrothermal energy using raw water from multi-purpose dams and regional water resources. Based on the analysis the evaluation system developed in this study is expected to be improved and supplemented.

Keywords

Acknowledgement

이 과제는 부산대학교 기본연구지원사업(2년)에 의하여 연구되었음.

References

  1. Ahn, S.G., Choi, G.S. and Park, S.Y. (2016). "Application case of heating and cooling system using the temperature difference of raw water in a dam", Proceedings of KIEE 2016 Summer Conference, 13-15 July, 2016, Yongpyeong, Korea, The Korean Institute of Electrical Engineers.
  2. Cho, G.T., Cho. Y.G., and Kang, H.S. (2003). Hierarchical decision-making by leading leaders, Dong-Hyun Publishing Company.
  3. Gyeongnam Newspaper, [Completion of carbon neutrality with hydrothermal energy] (1) Hydrothermal energy concept and domestic status (2022). https://www.knnews.co.kr/news/articleView.php?idxno=1379893 (February 25, 2024).
  4. Ham, S. Lee, K. and Yun, R. (2019). "Prediction of technical hydrothermal energy reserves", Proceedings of SAREK 2019 Summer Annual Conference, 19-21 June, 2019, Yongpyeong, Korea, The Society of Air-conditioning and Refrigerating Engineers of Korea.
  5. Huh, J.Y., Park, J.T., and Kim, S. (1998). "Heat energy potentials of river water in South Korea", Proceedings of SAREK 2022 Winter Annual Conference, 18 November, 2022, Seoul, Korea, The Society of Air-conditioning and Refrigerating Engineers of Korea.
  6. HVAC&R Journal, Lotte P&D World Mall & World Tower Energy Center Technology Safety Department Mall Technology Team Assistant Manager Choi Jae-won (2021). https://www.hvacrj.co.kr/news/articleView.html?idxno=20855 (February 25, 2024).
  7. Jeon, S., An, S., Choi, Y., and Sung, H. (2011). A study on the site selection for wind power using GIS, Korean Soc. New Renew. Energy, 7(3), 83-91. https://doi.org/10.7849/ksnre.2011.7.3.083
  8. Joo, S.M. and Choi, J.H. (2012). A study on the selection of optimal location for the photovoltaic power generation facilities in Daegu metropolitan city, J. Daegu Gyeongbuk Dev. Inst., 11(2), 173-183.
  9. Jung, Y. (2018). Estimation of the probable maximum water thermal energy in Korean dams based on the water-energy nexus concept, J. Korean Soc. Agric. Eng., 60(2), 45-53.
  10. Jung, Y. and Lee, H. (2019). "Energy and environmental investigation of river source heat pump systems", Proceedings of SAREK 2019 Winter Annual Conference, 22 November, 2019, Seoul, Korea, The Society of Air-conditioning and Refrigerating Engineers of Korea.
  11. Jung, J., Nam, J., Jung, S., Kim, J., and Kim, H.S. (2018). Feasibility study on the use of river water hydrothermal energy in Korea : (1) Estimation of the permitted standard discharge and determination of the potential water intake area, New Renew. Energy, 14(4), 27-37. https://doi.org/10.7849/ksnre.2018.12.14.4.027
  12. Jung, J., Nam, J., Kim, J., Jung, S., and Kim, H.S. (2019). Feasibility study on the use of river water hydrothermal energy in Korea : (2) Impact assessment of the change in water temperature of return flow on the river environment, New Renew. Energy, 15(1), 9-17.
  13. Kim, B.S, and Lee, M.J. (2015). A study on development strategy of industrial complex using SWOT/AHP analysis theory - The case of the firms in Seoul digital industrial complex, J. Inf. Syst. Korea Assoc. Inform. Syst., 24(4), 61-81.
  14. Kim, J., Ryoo, Y., and Park, M. (2015). Analysis of available capacity and relevant legal system for the use of temperature difference energy in a rural community, New Renew. Energy, 11(3), 21-27. https://doi.org/10.7849/ksnre.2015.09.11.3.21
  15. K-water. (2009). The study on heat source of raw water in Hangang area water supply system, YF-WEB-440142, 74-80.
  16. K-water. (2014). Temperature difference cooling and heating business model development and feasibility study, 255-270.
  17. K-water. (2019). Evaluation of impacts on water treatment efficiency and conveyance & transmission by utilzing water thermal energy, 2020-WS-RR-38-75, 83-85.
  18. K-water. (2020a). The analysis on the hydrothermal energy capacity and survey on possible application sites, 2020-RE-RR-20-1038, 3-56, 119-136, 216.
  19. K-water. (2020b). Study on the cooling and heating effect of water thermal energy system using stream water, KIWE-WEI-20-2, 40-80.
  20. Kwon, Y. and Nam, Y. (2022). Annual performance snalysis of river water source heat pump system according to building type and local condition, Korean J. Air-Cond. Refrig. Eng. 34(4), 163-171.
  21. Lee, G.J, Lee, G.H. and Kang, S.W. (2017). A case study for analyzing the optimal location for a solar power plant via AHP analysis with fine dust and weather information, J. Korea Saf. Manag. Sci., 19(4), 157-167.
  22. Lee, T.G., Kang, H.K., Lee, J.S., and Kim, D.R. (2019). "Feasibility study for applying cooling and thermal storage system using raw water", Proceedings of SAREK 2019 Winter Annual Conference, 22 November, 2019, Seoul, Korea, The Society of Air-conditioning and Refrigerating Engineers of Korea.
  23. Lee, T.G., Kang, H.K., Moon, J.H., and Park, Y.S. (2022). "Feasibility analysis of hydrothermal energy and demand forecast in the urban development stages", Proceedings of SAREK 2022 Winter Annual Conference, 18 November, 2022, Seoul, Korea, The Society of Air-conditioning and Refrigerating Engineers of Korea.
  24. Ministry of Environment. (2019). Research on measures to foster the hydrothermal industry, 11-1480000-001624-01, 121-135.
  25. Ministry of Government Legislation, Korean Law Information Center (2011). https://www.law.go.kr/LSW/admRulInfoP.do?admRulSeq=2000000061231&lsId=33590&chrClsCd=010202 (February 25, 2024).
  26. Ministry of Government Legislation, Korean Law Information Center (2016). https://www.law.go.kr/LSW/admRulInfoP.do?admRulSeq=2100000051379 (February 25, 2024).
  27. Ministry of Trade, Industry and Energy (2020). The 5th Basic Plan for Development and Use of Renewable Energy Technology, 9-36.
  28. Oh, K.M. and Kim., L.H. (2018). A study on the utilization of potential heat sources for heat pumps to district heating system in urban, Korean Chem. Eng. Res., 56(6), 841-855.
  29. Park, J.T. and Chang, K.C. (2002). An investigation on quantity of unused energy using temperature difference energy as heat source and its availability, J. Energy Eng., 11(2), 106-113.
  30. Park, I.H., Yoon, H.K., Park, J.T., Chang, K.C., and Lee, Y.S. (2005). A study on the potential energy reserve amount of domestic river water as unutilized energy resource, Korean J. Air-Cond. Refrig. Eng., 17(6), 521-529.
  31. The Seoul Institute (2020). A Study on Supply Strategy of Hydrothermal Energy in Seoul, 2020-PR-09, 3.
  32. Yang, C.H, Kim, Y and Chung, K.S. (2012). "Economical Analysis of a Small Capacity Water Source Heat Pump utilizing Unused Energy of Underground Water Tank", Proceedings of SAREK 2012 Summer Annual Conference, 18 November, 2012, Seoul, Korea, The Society of Air-conditioning and Refrigerating Engineers of Korea.