DOI QR코드

DOI QR Code

The cumulative survival rate of dental implants with micro-threads: a long-term retrospective study

  • Dong-Hui Nam (Department of Periodontology, School of Dentistry and Dental Research Institute, Seoul National University and Seoul National University Dental Hospital) ;
  • Pil-Jong Kim (Biomedical Knowledge Engineering Laboratory, School of Dentistry and Dental Research Institute, Seoul National University) ;
  • Ki-Tae Koo (Department of Periodontology, School of Dentistry and Dental Research Institute, Seoul National University and Seoul National University Dental Hospital) ;
  • Yang-Jo Seol (Department of Periodontology, School of Dentistry and Dental Research Institute, Seoul National University and Seoul National University Dental Hospital) ;
  • Yong-Moo Lee (Department of Periodontology, School of Dentistry and Dental Research Institute, Seoul National University and Seoul National University Dental Hospital) ;
  • Young Ku (Department of Periodontology, School of Dentistry and Dental Research Institute, Seoul National University and Seoul National University Dental Hospital) ;
  • In-Chul Rhyu (Department of Periodontology, School of Dentistry and Dental Research Institute, Seoul National University and Seoul National University Dental Hospital) ;
  • Sungtae Kim (Department of Periodontology, School of Dentistry and Dental Research Institute, Seoul National University and Seoul National University Dental Hospital) ;
  • Young-Dan Cho (Department of Periodontology, School of Dentistry and Dental Research Institute, Seoul National University and Seoul National University Dental Hospital)
  • 투고 : 2022.07.08
  • 심사 : 2022.11.29
  • 발행 : 2024.02.28

초록

Purpose: This study aimed to evaluate the long-term cumulative survival rate (CSR) of dental implants with micro-threads in the neck over a 10-year follow-up period and to examine the factors influencing the survival rate of dental implants. Methods: This retrospective study was based on radiographic and dental records. In total, 151 patients received 490 Oneplant® dental implants with an implant neck micro-thread design during 2006-2010 in the Department of Periodontology of Seoul National University Dental Hospital. Implant survival was evaluated using Kaplan-Meier analysis. Cox proportional hazard regression analysis was used to identify the factors influencing implant failure. Results: Ten out of 490 implants (2.04%) failed due to fixture fracture. The CSR of the implants was 97.9%, and no significant difference was observed in the CSR between external-and internal-implant types (98.2% and 97.6%, respectively, P=0.670). In Cox regression analysis, 2-stage surgery significantly increased the risk of implant failure (hazard ratio: 4.769, P=0.039). There were no significant differences in influencing factors, including sex, age, implant diameter, length, fixture type, location, surgical procedure, bone grafting, and restoration type. Conclusions: Within the limitations of this retrospective study, the micro-thread design of the implant neck was found to be favorable for implant survival, with stable clinical outcomes.

키워드

과제정보

This work was supported by a research grant from Warantec Co., Ltd (No. CDE21010).

참고문헌

  1. Branemark PI. Osseointegration and its experimental background. J Prosthet Dent 1983;50:399-410. https://doi.org/10.1016/S0022-3913(83)80101-2
  2. Alghamdi HS, Jansen JA. The development and future of dental implants. Dent Mater J 2020;39:167-72. https://doi.org/10.4012/dmj.2019-140
  3. Cho YD, Kim WJ, Ryoo HM, Ku Y. Patent landscape report on dental implants: a technical analysis. Clin Implant Dent Relat Res 2021;23:857-63. https://doi.org/10.1111/cid.13048
  4. Jung RE, Zembic A, Pjetursson BE, Zwahlen M, Thoma DS. Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years. Clin Oral Implants Res 2012;23 Suppl 6:2-21. https://doi.org/10.1111/j.1600-0501.2012.02547.x
  5. Hjalmarsson L, Gheisarifar M, Jemt T. A systematic review of survival of single implants as presented in longitudinal studies with a follow-up of at least 10 years. Eur J Oral Implantology 2016;9 Suppl 1:S155-62. 
  6. Jung RE, Pjetursson BE, Glauser R, Zembic A, Zwahlen M, Lang NP. A systematic review of the 5-year survival and complication rates of implant-supported single crowns. Clin Oral Implants Res 2008;19:119-30. https://doi.org/10.1111/j.1600-0501.2007.01453.x
  7. Blanco J, Alonso A, Sanz M. Long-term results and survival rate of implants treated with guided bone regeneration: a 5-year case series prospective study. Clin Oral Implants Res 2005;16:294-301.  https://doi.org/10.1111/j.1600-0501.2005.01106.x
  8. Albrektsson T, Zarb G, Worthington P, Eriksson AR. The long-term efficacy of currently used dental implants: a review and proposed criteria of success. Int J Oral Maxillofac Implants 1986;1:11-25.
  9. Buser D, Mericske-Stern R, Bernard JP, Behneke A, Behneke N, Hirt HP, et al. Long-term evaluation of non-submerged ITI implants. Part 1: 8-year life table analysis of a prospective multi-center study with 2359 implants. Clin Oral Implants Res 1997;8:161-72. https://doi.org/10.1034/j.1600-0501.1997.080302.x
  10. Misch CE, Perel ML, Wang HL, Sammartino G, Galindo-Moreno P, Trisi P, et al. Implant success, survival, and failure: the International Congress of Oral Implantologists (ICOI) Pisa Consensus Conference. Implant Dent 2008;17:5-15. https://doi.org/10.1097/ID.0b013e3181676059
  11. Papaspyridakos P, Chen CJ, Singh M, Weber HP, Gallucci GO. Success criteria in implant dentistry: a systematic review. J Dent Res 2012;91:242-8. https://doi.org/10.1177/0022034511431252
  12. Wennerberg A, Albrektsson T. Effects of titanium surface topography on bone integration: a systematic review. Clin Oral Implants Res 2009;20 Suppl 4:172-84. https://doi.org/10.1111/j.1600-0501.2009.01775.x
  13. Sykaras N, Iacopino AM, Marker VA, Triplett RG, Woody RD. Implant materials, designs, and surface topographies: their effect on osseointegration. A literature review. Int J Oral Maxillofac Implants 2000;15:675-90.
  14. Abrahamsson I, Berglundh T, Linder E, Lang NP, Lindhe J. Early bone formation adjacent to rough and turned endosseous implant surfaces. An experimental study in the dog. Clin Oral Implants Res 2004;15:381-92. https://doi.org/10.1111/j.1600-0501.2004.01082.x
  15. Botticelli D, Berglundh T, Persson LG, Lindhe J. Bone regeneration at implants with turned or rough surfaces in self-contained defects. An experimental study in the dog. J Clin Periodontol 2005;32:448-55. https://doi.org/10.1111/j.1600-051X.2005.00693.x
  16. Steigenga JT, al-Shammari KF, Nociti FH, Misch CE, Wang HL. Dental implant design and its relationship to long-term implant success. Implant Dent 2003;12:306-17. https://doi.org/10.1097/01.ID.0000091140.76130.A1
  17. Lan TH, Du JK, Pan CY, Lee HE, Chung WH. Biomechanical analysis of alveolar bone stress around implants with different thread designs and pitches in the mandibular molar area. Clin Oral Investig 2012;16:363-9. https://doi.org/10.1007/s00784-011-0517-z
  18. Lee JY, Park HJ, Kim JE, Choi YG, Kim YS, Huh JB, et al. A 5-year retrospective clinical study of the Dentium implants. J Adv Prosthodont 2011;3:229-35. https://doi.org/10.4047/jap.2011.3.4.229
  19. Lee DW, Choi YS, Park KH, Kim CS, Moon IS. Effect of microthread on the maintenance of marginal bone level: a 3-year prospective study. Clin Oral Implants Res 2007;18:465-70. https://doi.org/10.1111/j.1600-0501.2007.01302.x
  20. Hudieb MI, Wakabayashi N, Kasugai S. Magnitude and direction of mechanical stress at the osseointegrated interface of the microthread implant. J Periodontol 2011;82:1061-70. https://doi.org/10.1902/jop.2010.100237
  21. Greenstein G, Cavallaro J. Implant insertion torque: its role in achieving primary stability of restorable dental implants. Compend Contin Educ Dent 2017;38:88-95.
  22. Oh TJ, Yoon J, Misch CE, Wang HL. The causes of early implant bone loss: myth or science? J Periodontol 2002;73:322-33. https://doi.org/10.1902/jop.2002.73.3.322
  23. Guo XE. Mechanical properties of cortical bone and cancellous bone tissue. In: Cowin SC, editor. Bone mechanics handbook. Boca Raton: CRC Press; 2001. p.1-23. 
  24. Song DW, Lee DW, Kim CK, Park KH, Moon IS. Comparative analysis of peri-implant marginal bone loss based on microthread location: a 1-year prospective study after loading. J Periodontol 2009;80:1937-44. https://doi.org/10.1902/jop.2009.090330
  25. Al-Thobity AM, Kutkut A, Almas K. Microthreaded implants and crestal bone loss: a systematic review. J Oral Implantol 2017;43:157-66. https://doi.org/10.1563/aaid-joi-D-16-00170
  26. Troiano G, Lo Russo L, Canullo L, Ciavarella D, Lo Muzio L, Laino L. Early and late implant failure of submerged versus non-submerged implant healing: a systematic review, meta-analysis and trial sequential analysis. J Clin Periodontol 2018;45:613-23. https://doi.org/10.1111/jcpe.12890
  27. Ikebe K, Wada M, Kagawa R, Maeda Y. Is old age a risk factor for dental implants? Jpn Dent Sci Rev 2009;45:59-64. https://doi.org/10.1016/j.jdsr.2009.02.001
  28. Olmedo-Gaya MV, Manzano-Moreno FJ, Canaveral-Cavero E, de Dios Luna-del Castillo J, Vallecillo-Capilla M. Risk factors associated with early implant failure: a 5-year retrospective clinical study. J Prosthet Dent 2016;115:150-5.  https://doi.org/10.1016/j.prosdent.2015.07.020
  29. Manzano G, Montero J, Martin-Vallejo J, Del Fabbro M, Bravo M, Testori T. Risk factors in early implant failure: a meta-analysis. Implant Dent 2016;25:272-80. https://doi.org/10.1097/ID.0000000000000386
  30. Wyatt CC, Zarb GA. Treatment outcomes of patients with implant-supported fixed partial prostheses. Int J Oral Maxillofac Implants 1998;13:204-11.
  31. Flores-Guillen J, Alvarez-Novoa C, Barbieri G, Martin C, Sanz M. Five-year outcomes of a randomized clinical trial comparing bone-level implants with either submerged or transmucosal healing. J Clin Periodontol 2018;45:125-35. https://doi.org/10.1111/jcpe.12832
  32. Sanz M, Ivanoff CJ, Weingart D, Wiltfang J, Gahlert M, Cordaro L, et al. Clinical and radiologic outcomes after submerged and transmucosal implant placement with two-piece implants in the anterior maxilla and mandible: 3-year results of a randomized controlled clinical trial. Clin Implant Dent Relat Res 2015;17:234-46. https://doi.org/10.1111/cid.12107
  33. Zitzmann NU, Scharer P, Marinello CP. Long-term results of implants treated with guided bone regeneration: a 5-year prospective study. Int J Oral Maxillofac Implants 2001;16:355-66.
  34. Katsavochristou A, Koumoulis D. Incidence of abutment screw failure of single or splinted implant prostheses: a review and update on current clinical status. J Oral Rehabil 2019;46:776-86. https://doi.org/10.1111/joor.12817
  35. De Bruyn H, Collaert B. The effect of smoking on early implant failure. Clin Oral Implants Res 1994;5:260-4. https://doi.org/10.1034/j.1600-0501.1994.050410.x
  36. Naseri R, Yaghini J, Feizi A. Levels of smoking and dental implants failure: a systematic review and meta-analysis. J Clin Periodontol 2020;47:518-28. https://doi.org/10.1111/jcpe.13257
  37. Hong JY, Shin EY, Herr Y, Chung JH, Lim HC, Shin SI. Implant survival and risk factor analysis in regenerated bone: results from a 5-year retrospective study. J Periodontal Implant Sci 2020;50:379-91. https://doi.org/10.5051/jpis.2002140107
  38. Fiorellini JP, Chen PK, Nevins M, Nevins ML. A retrospective study of dental implants in diabetic patients. Int J Periodontics Restorative Dent 2000;20:366-73.
  39. Asvanund P, Morgano SM. Photoelastic stress analysis of external versus internal implant-abutment connections. J Prosthet Dent 2011;106:266-71. https://doi.org/10.1016/S0022-3913(11)60128-5
  40. Albrektsson T, Donos N; Working Group 1. Implant survival and complications. The Third EAO consensus conference 2012. Clin Oral Implants Res 2012;23 Suppl 6:63-5. https://doi.org/10.1111/j.1600-0501.2012.02557.x