참고문헌
- Son SY, Min JW, Jeong HW, et al. Evaluation of image quality for various electronic portal imaging devices in radiation therapy. Journal of Radiological Science and Technology. 2015;38(4);451-61. Retrieved from https://ocean.kisti.re.kr/IS_mvpopo212L.do?ResultTotalCNT=19&pageNo=2&pageSize=10&method=list&acnCn1=&poid=ksrs1&kojic=BSSGBL&sVnc=v38n4&id=&setId=&iTableId=&iDocId=&sFree=&pQuery=%28kojic%3ABSSGBL%29+AND+%28voliss_ctrl_no%3Av38n4%29 https://doi.org/10.17946/JRST.2015.38.4.16
- Miyati T, Fujita H, Kasuga T, et al. Measurements of MTF and SNR(f) using a subtraction method im MRI. Physics in Medicine and Biology. 2002;47: 2961-72. Doi: 10.1088/0031-9155/47/16/311.
- Min JW, Jeong HW, Kim KW, et al. Comparison study on CNR and SNR of thoracic spine Lateral radiography. Journal of Radiological Science and Technology. 2013;36(4):280-73. Retrieved from https://ocean.kisti.re.kr/IS_mvpopo212L.do?method=list&poid=ksrs1&kojic=BSS GBL& sVnc=v36n4&sFree=
- Lee YJ, Jung HS, Kim YJ, et al. Optimization of non-local means algorithm in low-dose computed tomographic image using noise level and similarity evaluation parameters: A phantom study. Journal of Radiological Science and Technology. 2024;47(1): 39-48. DOI: http://dx.doi.org/10.17946/JRST.2024.47.1.39
- Min JW, Jeong HW, Kim KW, et al. Study on the resolution characteristics by using magnetic resonance imaging 3.0T. Journal of Radiological Science and Technology. 2020;43(4):251-7. Retrieved from http://ocean.kisti.re.kr/IS_mvpopo212L.do? method=l ist&poid=ksrs1&kojic=BSSGBL&sVnc=v43n4&sFree= https://doi.org/10.17946/JRST.2020.43.4.251
- Min JW, Jeong HW, Kim SC. Evaluation of noise power spectrum characteristics by using magnetic resonance imaging 3.0T. Journal of Radiological Science and Technology. 2021;44(1):279-88. Retrieved from http://ocean.kisti.re.kr/IS_mvpopo212L.do?method=list&poid=ksrs1&kojic=BSSGBL&sVnc=v44n1&sFree=
- Min JW, Jeong HW, Han JH, et al. Evaluation of the resolution characteristics by using american college of radiology phantom for magnetic resonance imaging. Journal of Radiological Science and Technology. 2022;45(1):11-7. DOI: http://dx.doi.org/10.17946/JRST.2022.45.1.11
- Jeong HW, Min JW, Kim JM, et al. Performance characteristic of a CsI(Tl) flat panel detector radiography system. Journal of Radiological Science and Technology. 2012;35(2):109-17. Retrieved from http://ocean.kisti.re.kr/IS_mvpopo212L.do?method=list&poid=ksrs1&kojic=BSSGBL&sVnc=v35n2&sFree=
- Min JW, Jeong HW, Kang HK. Evaluation of the resolution characteristics by using ATS 535H phantom for ultrasound medical imaging. Journal of Radiological Science and Technology. 2023;46(1): 15-21. DOI: http://dx.doi.org/10.17946/JRST.2023.46.1.15
- Kim KW, Jeong HW, Min JW, et al. Measurement of image quality according to the time of computed radiography system. Journal of Radiological Science and Technology. 2015;38(4):365-74. Retrieved from http://ocean.kisti.re.kr/IS_mvpopo212L.do?method=list&poid=ksrs1&kojic=BSSGBL&sVnc=v38n4&sFree= https://doi.org/10.17946/JRST.2015.38.4.05
- Min JW, Jeong HW, Kim KW, et al. Comparison of noise power spectrum in measurements by using international electrotechnical commission standard devices in indirect digital radiography. Journal of Radiological Science and Technology. 2018;41(5): 457-62. Retrieved from http://ocean.kisti.re.kr/IS_mvpopo212L.do?method=list&poid=ksrs1&kojic=BSSGBL&sVnc=v41n5&sFree= https://doi.org/10.17946/JRST.2018.41.5.457
- IEC (International Electrotechnical Commission) 62220-1. Medical electrical equipment characteristics of digital X-ray imaging devices Part 1: determination of the detective quantum efficiency. Geneva; 2003. Retrieved from http://websites.umich.edu/~ners580/ners-bioe_481/lectures/pdfs/2003-10-IEC_62220-DQE.pdf
- Samei E, Flynn MJ, Reimann DA, et al. A method for measuring the presampled MTF of digital radiographic systems using an edge test device. Medical Physics. 1998;25(1):102-13. Doi: 10.1118/1.598165.
- Greer PB, van Doorn T. Evaluation of an algorithm for the assessment of the MTF using an edge method. Medical Physics. 2000;27(9):2048-59. Doi: 10.1118/1.1288682.
- Steckner MC, Drost DJ, Prato FS. Computing the modulation transfer function of a magnetic resonance imager. Medical Physics. 1994;21(3):483-9. Doi: 10.1118/1.597310.