DOI QR코드

DOI QR Code

Comparison of different digital shade selection methodologies in terms of accuracy

  • Nursen Sahin (Department of Prosthodontics, Faculty of Dentistry, Giresun University) ;
  • Cagri Ural (Department of Prosthodontics, Faculty of Dentistry, Ondokuz Mayis University)
  • Received : 2023.08.04
  • Accepted : 2024.02.08
  • Published : 2024.02.29

Abstract

PURPOSE. This study aims to evaluate the accuracy of different shade selection techniques and determine the matching success of crown restorations fabricated using digital shade selection techniques. MATERIALS AND METHODS. Teeth numbers 11 and 21 were prepared on a typodont model. For the #11 tooth, six different crowns were fabricated with randomly selected colors and set as the target crowns. The following four test groups were established: Group C, where the visual shade selection was performed using the Vita 3D Master Shade Guide and the group served as the control; Group Ph, where the shade selection was performed under the guidance of dental photography; Group S, where the shade selection was performed by measuring the target tooth color using a spectrophotometer; and Group I, where the shade selection was performed by scanning the test specimens and target crowns using an intraoral scanner. Based on the test groups, 24 crowns were fabricated using different shade selection techniques. The ΔE values were calculated according to the CIEDE2000 (2:1:1) formula. The collected data were analyzed by means of a one-way analysis of variance. RESULTS. For the four test groups (Groups C, Ph, S, and I), the following mean ΔE values were obtained: 2.74, 3.62, 2.13, and 3.5, respectively. No significant differences were found among the test groups. CONCLUSION. Although there was no statistically significant difference among the shade selection techniques, Group S had relatively lower ΔE values. Moreover, according to the test results, the spectrophotometer shade selection technique may provide more successful clinical results.

Keywords

References

  1. Kahramanoglu E, Ozkan YK. Esthetic and color in dentistry. Cumhuriyet Dent J 2013;16:339-47. 
  2. Yilmaz B. Factors affecting the visual tooth shade selection: a review. Dent Med J - R 2020;2:76-83. 
  3. Basavanna RS, Gohil C, Shivanna V. Shade selection. Int J Oral Health Sci 2013;3:26-31.  https://doi.org/10.4103/2231-6027.122097
  4. Joiner A, Luo W. Tooth colour and whiteness: A review. J Dent 2017;67S:S3-10.  https://doi.org/10.1016/j.jdent.2017.09.006
  5. Tabatabaian F, Namdari M, Mahshid M, Vora SR, Mirabbasi S. Accuracy and precision of intraoral scanners for shade matching: A systematic review. J Prosthet Dent 2022:S0022-3913(22)00565-0. Online ahead of print. 
  6. Jorquera GJ, Atria PJ, Galan M, Feureisen J, Imbarak M, Kernitsky J, Cacciuttolo F, Hirata R, Sampaio CS. A comparison of ceramic crown color difference between different shade selection methods: Visual, digital camera, and smartphone. J Prosthet Dent 2022;128:784-92.  https://doi.org/10.1016/j.prosdent.2020.07.029
  7. Kroger E, Matz S, Dekiff M, Tran BL, Figgener L, Dirksen D. In vitro comparison of instrumental and visual tooth shade determination under different illuminants. J Prosthet Dent 2015;114:848-55.  https://doi.org/10.1016/j.prosdent.2015.06.004
  8. Igiel C, Weyhrauch M, Wentaschek S, Scheller H, Lehmann KM. Dental color matching: A comparison between visual and instrumental methods. Dent Mater J 2016;35:63-9.  https://doi.org/10.4012/dmj.2015-006
  9. Ristic I, Stankovic S, Paravina RD. Influence of color education and training on shade matching skills. J Esthet Restor Dent 2016;28:287-94.  https://doi.org/10.1111/jerd.12209
  10. Nakhaei M, Ghanbarzadeh J, Keyvanloo S, Alavi S, Jafarzadeh H. Shade matching performance of dental students with three various lighting conditions. J Contemp Dent Pract 2013;14:100-3.  https://doi.org/10.5005/jp-journals-10024-1279
  11. Turgut S, Bagis B. Color in dentistry and color measuring methods. J Dent Fac Ataturk Uni 2012;5:65-75. 
  12. Cone MR, Choi J, Awdaljan M. Optimized digital shade calibration technology for the restoration of a single central incisor. J Prosthet Dent 2022;128:1-3.  https://doi.org/10.1016/j.prosdent.2022.05.027
  13. Alsaleh S, Labban M, AlHariri M, Tashkandi E. Evaluation of self shade matching ability of dental students using visual and instrumental means. J Dent 2012;40 Suppl 1:e82-7.  https://doi.org/10.1016/j.jdent.2012.01.009
  14. Mahn E, Tortora SC, Olate B, Cacciuttolo F, Kernitsky J, Jorquera G. Comparison of visual analog shade matching, a digital visual method with a cross-polarized light filter, and a spectrophotometer for dental color matching. J Prosthet Dent 2021;125:511-6.  https://doi.org/10.1016/j.prosdent.2020.02.002
  15. Parameswaran V, Anilkumar S, Lylajam S, Rajesh C, Narayan V. Comparison of accuracies of an intraoral spectrophotometer and conventional visual method for shade matching using two shade guide systems. J Indian Prosthodont Soc 2016;16:352-8.  https://doi.org/10.4103/0972-4052.176537
  16. Liberato WF, Barreto IC, Costa PP, de Almeida CC, Pimentel W, Tiossi R. A comparison between visual, intraoral scanner, and spectrophotometer shade matching: A clinical study. J Prosthet Dent 2019;121:271-5.  https://doi.org/10.1016/j.prosdent.2018.05.004
  17. Hampe-Kautz V, Salehi A, Senger B, Etienne O. A comparative in vivo study of new shade matching procedures. Int J Comput Dent 2020;23:317-23. 
  18. Yoon HI, Bae JW, Park JM, Chun YS, Kim MA, Kim M. A study on possibility of clinical application for color measurements of shade guides using an intraoral digital scanner. J Prosthodont 2018;27:670-5.  https://doi.org/10.1111/jopr.12559
  19. Dozic A, Kleverlaan CJ, El-Zohairy A, Feilzer AJ, Khashayar G. Performance of five commercially available tooth color-measuring devices. J Prosthodont 2007;16:93-100.  https://doi.org/10.1111/j.1532-849X.2007.00163.x
  20. Tsiliagkou A, Diamantopoulou S, Papazoglou E, Kakaboura A. Evaluation of reliability and validity of three dental color-matching devices. Int J Esthet Dent 2016;11:110-24. 
  21. Oroglu A, Makhloota M, Turhan BAL B. A review of color matching in dentistry. Med Records 2021;3:44-9.  https://doi.org/10.37990/medr.818367
  22. Miyajiwala JS, Kheur MG, Patankar AH, Lakha TA. Comparison of photographic and conventional methods for tooth shade selection: A clinical evaluation. J Indian Prosthodont Soc 2017;17:273-81.  https://doi.org/10.4103/jips.jips_342_16
  23. Alshiddi IF, Richards LC. A comparison of conventional visual and spectrophotometric shade taking by trained and untrained dental students. Aust Dent J 2015;60:176-81.  https://doi.org/10.1111/adj.12311
  24. Paul S, Peter A, Pietrobon N, Hammerle CH. Visual and spectrophotometric shade analysis of human teeth. J Dent Res 2002;81:578-82.  https://doi.org/10.1177/154405910208100815
  25. Recen D, Onal B, Turkun LS . The effect of experience on composite resin shade selection in comparison to a spectrophotometer. Acta Odontol Tuc 2016;33:12-7. 
  26. Dudea D, Gasparik C, Botos A, Alb F, Irimie A, Paravina RD. Influence of background/surrounding area on accuracy of visual color matching. Clin Oral Investig 2016;20:1167-73.  https://doi.org/10.1007/s00784-015-1620-3
  27. Dagg H, O'Connell B, Claffey N, Byrne D, Gorman C. The influence of some different factors on the accuracy of shade selection. J Oral Rehabil 2004;31:900-4.  https://doi.org/10.1111/j.1365-2842.2004.01310.x
  28. Reyes J, Acosta P, Ventura D. Repeatability of the human eye compared to an intraoral scanner in dental shade matching. Heliyon 2019;5:e02100. 
  29. Bahannan SA. Shade matching quality among dental students using visual and instrumental methods. J Dent 2014;42:48-52.  https://doi.org/10.1016/j.jdent.2013.11.001
  30. Pohlen B, Hawlina M, Sober K, Kopac I. Tooth shade-matching ability between groups of students with different color knowledge. Int J Prosthodont 2016;29:487-92.  https://doi.org/10.11607/ijp.4712
  31. Mehl A, Bosch G, Fischer C, Ender A. In vivo tooth-color measurement with a new 3D intraoral scanning system in comparison to conventional digital and visual color determination methods. Int J Comput Dent 2017;20:343-61. 
  32. Da Silva JD, Park SE, Weber HP, Ishikawa-Nagai S. Clinical performance of a newly developed spectrophotometric system on tooth color reproduction. J Prosthet Dent 2008;99:361-8.  https://doi.org/10.1016/S0022-3913(08)60083-9
  33. Jorquera GJ, Atria PJ, Galan M, Feureisen J, Imbarak M, Kernitsky J, Cacciuttolo F, Hirata R, Sampaio CS. A comparison of ceramic crown color difference between different shade selection methods: Visual, digital camera, and smartphone. J Prosthet Dent 2022;128:784-92.  https://doi.org/10.1016/j.prosdent.2020.07.029
  34. Tung FF, Goldstein GR, Jang S, Hittelman E. The repeatability of an intraoral dental colorimeter. J Prosthet Dent 2002;88:585-90.  https://doi.org/10.1067/mpr.2002.129803
  35. Ebeid K, Sabet A, Della Bona A. Accuracy and repeatability of different intraoral scanners on shade determination. J Esthet Restor Dent 2021;33:844-8.  https://doi.org/10.1111/jerd.12687
  36. Lazar R, Culic B, Gasparik C, Lazar C, Dudea D. The accuracy of dental shade matching using cross-polarization photography. Int J Comput Dent 2019;22:343-51. 
  37. Lazar R, Dudea D, Gasparik C, Lazar D, Jula C, Culic B. Assessment of a new photographic system used in dentistry. Optoelectronics Adv Mater 2016;10:426-32. 
  38. Khurana R, Tredwin CJ, Weisbloom M, Moles DR. A clinical evaluation of the individual repeatability of three commercially available colour measuring devices. Br Dent J 2007;203:675-80.  https://doi.org/10.1038/bdj.2007.1108
  39. Igiel C, Lehmann KM, Ghinea R, Weyhrauch M, Hangx Y, Scheller H, Paravina RD. Reliability of visual and instrumental color matching. J Esthet Restor Dent 2017;29:303-8.  https://doi.org/10.1111/jerd.12321
  40. Gomez-Polo C, Portillo Munoz M, Lorenzo Luengo MC, Vicente P, Galindo P, Martin Casado AM. Comparison of the CIELab and CIEDE2000 color difference formulas. J Prosthet Dent 2016;115:65-70.  https://doi.org/10.1016/j.prosdent.2015.07.001
  41. Perez MM, Della Bona A, Carrillo-Perez F, Dudea D, Pecho OE, Herrera LJ. Does background color influence visual thresholds? J Dent 2020;102:103475. 
  42. Ghinea R, Perez MM, Herrera LJ, Rivas MJ, Yebra A, Paravina RD. Color difference thresholds in dental ceramics. J Dent 2010;38 Suppl 2:e57-64.  https://doi.org/10.1016/j.jdent.2010.07.008
  43. Mahn E, Tortora SC, Olate B, Cacciuttolo F, Kernitsky J, Jorquera G. Comparison of visual analog shade matching, a digital visual method with a cross-polarized light filter, and a spectrophotometer for dental color matching. J Prosthet Dent 2021;125:511-6.  https://doi.org/10.1016/j.prosdent.2020.02.002
  44. Borse S, Chaware SH. Tooth shade analysis and selection in prosthodontics: A systematic review and meta-analysis. J Indian Prosthodont Soc 2020;20:131-40.  https://doi.org/10.4103/jips.jips_399_19
  45. Paravina RD, Ontiveros JC, Powers JM. Accelerated aging effects on color and translucency of bleaching-shade composites. J Esthet Restor Dent 2004;16:117-27.  https://doi.org/10.1111/j.1708-8240.2004.tb00018.x
  46. Brandt J, Nelson S, Lauer HC, von Hehn U, Brandt S. In vivo study for tooth colour determination-visual versus digital. Clin Oral Investig 2017;21:2863-71.  https://doi.org/10.1007/s00784-017-2088-0
  47. Browning WD, Chan DC, Blalock JS, Brackett MG. A comparison of human raters and an intra-oral spectrophotometer. Oper Dent 2009;34:337-43.  https://doi.org/10.2341/08-106
  48. Wee AG, Lindsey DT, Shroyer KM, Johnston WM. Use of a porcelain color discrimination test to evaluate color difference formulas. J Prosthet Dent 2007;98:101-9.  https://doi.org/10.1016/S0022-3913(07)60043-2
  49. Ahmadzadeh A, Mansourinejad S, Mansourinejad S, Rohani A. Spectrophotometric comparison of two porcelain systems, VMK master and VM13 with the VITA 3D-master shade guide (An in vitro study). Dent Res J 2022;19:35. 
  50. Kielbassa AM, Beheim-Schwarzbach NJ, Neumann K, Nat R, Zantner C. In vitro comparison of visual and computer-aided pre- and post-tooth shade determination using various home bleaching procedures. J Prosthet Dent 2009;101:92-100.  https://doi.org/10.1016/S0022-3913(09)60001-9
  51. Yuan JC, Brewer JD, Monaco EA Jr, Davis EL. Defining a natural tooth color space based on a 3-dimensional shade system. J Prosthet Dent 2007;98:110-9.  https://doi.org/10.1016/S0022-3913(07)60044-4
  52. Huang M, Wang Y, Sun Y, Zhou Y, Liu Y, Ye H. The accuracies of three intraoral scanners with regard to shade determination: An in vitro study. J Prosthodont 2023;32:111-7.  https://doi.org/10.1111/jopr.13808
  53. ISO/TR 28642. Dentistry - Guidance on colour measurement. International Standards Organization (ISO); Geneva; Switzerland, 2016.