Acknowledgement
This research was supported by a Mahidol University Faculty of Dentistry Grant (grant numbers DTRS-EG-2019-11, 2019).
References
- Smith BG, Bartlett DW, Robb ND. The prevalence, etiology and management of tooth wear in the United Kingdom. J Prosthet Dent 1997;78:367-72. https://doi.org/10.1016/S0022-3913(97)70043-X
- Lambrechts P, Braem M, Vuylsteke-Wauters M, Vanherle G. Quantitative in vivo wear of human enamel. J Dent Res 1989;68:1752-4. https://doi.org/10.1177/00220345890680120601
- Kelly JR, Benetti P. Ceramic materials in dentistry: historical evolution and current practice. Aust Dent J 2011;56 Suppl 1:84-96. https://doi.org/10.1111/j.1834-7819.2010.01299.x
- Conrad HJ, Seong WJ, Pesun IJ. Current ceramic materials and systems with clinical recommendations: a systematic review. J Prosthet Dent 2007;98:389-404. https://doi.org/10.1016/S0022-3913(07)60124-3
- Pjetursson BE, Sailer I, Zwahlen M, Hammerle CH. A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part I: Single crowns. Clin Oral Implants Res 2007;18 Suppl 3:73-85. https://doi.org/10.1111/j.1600-0501.2007.01467.x
- Mitov G, Heintze SD, Walz S, Woll K, Muecklich F, Pospiech P. Wear behavior of dental Y-TZP ceramic against natural enamel after different finishing procedures. Dent Mater 2012;28:909-18. https://doi.org/10.1016/j.dental.2012.04.010
- Sannino G, Germano F, Arcuri L, Bigelli E, Arcuri C, Barlattani A. CEREC CAD/CAM chairside system. Oral Implantol (Rome) 2015;7:57-70.
- Piconi C, Maccauro G. Zirconia as a ceramic biomaterial. Biomaterials 1999;20:1-25. https://doi.org/10.1016/S0142-9612(98)00010-6
- Larsson C, Vult von Steyern P, Nilner K. A prospective study of implant-supported full-arch yttria-stabilized tetragonal zirconia polycrystal mandibular fixed dental prostheses: three-year results. Int J Prosthodont 2010;23:364-9.
- Janyavula S, Lawson N, Cakir D, Beck P, Ramp LC, Burgess JO. The wear of polished and glazed zirconia against enamel. J Prosthet Dent 2013;109:22-9. https://doi.org/10.1016/S0022-3913(13)60005-0
- Preis V, Weiser F, Handel G, Rosentritt M. Wear performance of monolithic dental ceramics with different surface treatments. Quintessence Int 2013;44:393-405.
- Preis V, Hahnel S, Kolbeck C, Behrend D, Warkentin M, Handel G, Rosentritt M. Wear performance of dental materials: a comparison of substructure ceramics, veneering ceramics, and non-precious alloys. Adv Eng Mater 2011;13:B432-9. https://doi.org/10.1002/adem.201180015
- Kim MJ, Oh SH, Kim JH, Ju SW, Seo DG, Jun SH, Ahn JS, Ryu JJ. Wear evaluation of the human enamel opposing different Y-TZP dental ceramics and other porcelains. J Dent 2012;40:979-88. https://doi.org/10.1016/j.jdent.2012.08.004
- Rosentritt M, Preis V, Behr M, Hahnel S, Handel G, Kolbeck C. Two-body wear of dental porcelain and substructure oxide ceramics. Clin Oral Investig 2012;16:935-43. https://doi.org/10.1007/s00784-011-0589-9
- Mormann WH, Stawarczyk B, Ender A, Sener B, Attin T, Mehl A. Wear characteristics of current aesthetic dental restorative CAD/CAM materials: two-body wear, gloss retention, roughness and Martens hardness. J Mech Behav Biomed Mater 2013;20:113-25. https://doi.org/10.1016/j.jmbbm.2013.01.003
- Stawarczyk B, Ozcan M, Schmutz F, Trottmann A, Roos M, Hammerle CH. Two-body wear of monolithic, veneered and glazed zirconia and their corresponding enamel antagonists. Acta Odontol Scand 2013;71:102-12. https://doi.org/10.3109/00016357.2011.654248
- Sripetchdanond J, Leevailoj C. Wear of human enamel opposing monolithic zirconia, glass ceramic, and composite resin: an in vitro study. J Prosthet Dent 2014;112:1141-50. https://doi.org/10.1016/j.prosdent.2014.05.006
- Lawson NC, Janyavula S, Syklawer S, McLaren EA, Burgess JO. Wear of enamel opposing zirconia and lithium disilicate after adjustment, polishing and glazing. J Dent 2014;42:1586-91. https://doi.org/10.1016/j.jdent.2014.09.008
- Heintze SD, Cavalleri A, Forjanic M, Zellweger G, Rousson V. Wear of ceramic and antagonist-a systematic evaluation of influencing factors in vitro. Dent Mater 2008;24:433-49. https://doi.org/10.1016/j.dental.2007.06.016
- Jung YS, Lee JW, Choi YJ, Ahn JS, Shin SW, Huh JB. A study on the in-vitro wear of the natural tooth structure by opposing zirconia or dental porcelain. J Adv Prosthodont 2010;2:111-5.
- Heintze SD. How to qualify and validate wear simulation devices and methods. Dent Mater 2006;22:712-34. https://doi.org/10.1016/j.dental.2006.02.002
- Passos SP, Torrealba Y, Major P, Linke B, Flores-Mir C, Nychka JA. In vitro wear behavior of zirconia opposing enamel: a systematic review. J Prosthodont 2014; 23:593-601. https://doi.org/10.1111/jopr.12167
- Etman MK, Woolford M, Dunne S. Quantitative measurement of tooth and ceramic wear: in vivo study. Int J Prosthodont 2008;21:245-52.
- Esquivel-Upshaw J, Rose W, Oliveira E, Yang M, Clark AE, Anusavice K. Randomized, controlled clinical trial of bilayer ceramic and metal-ceramic crown performance. J Prosthodont 2013;22:166-73. https://doi.org/10.1111/j.1532-849X.2012.00913.x
- Suputtamongkol K, Anusavice KJ, Suchatlampong C, Sithiamnuai P, Tulapornchai C. Clinical performance and wear characteristics of veneered lithia-disilicate-based ceramic crowns. Dent Mater 2008;24:667-73. https://doi.org/10.1016/j.dental.2007.06.033
- Silva NR, Thompson VP, Valverde GB, Coelho PG, Powers JM, Farah JW, Esquivel-Upshaw J. Comparative reliability analyses of zirconium oxide and lithium disilicate restorations in vitro and in vivo. J Am Dent Assoc 2011;142 Suppl 2:4S-9S. https://doi.org/10.14219/jada.archive.2011.0336
- Stober T, Bermejo JL, Rammelsberg P, Schmitter M. Enamel wear caused by monolithic zirconia crowns after 6 months of clinical use. J Oral Rehabil 2014;41:314-22. https://doi.org/10.1111/joor.12139
- Mundhe K, Jain V, Pruthi G, Shah N. Clinical study to evaluate the wear of natural enamel antagonist to zirconia and metal ceramic crowns. J Prosthet Dent 2015;114:358-63. https://doi.org/10.1016/j.prosdent.2015.03.001
- Stober T, Bermejo JL, Schwindling FS, Schmitter M. Clinical assessment of enamel wear caused by monolithic zirconia crowns. J Oral Rehabil 2016;43:621-9. https://doi.org/10.1111/joor.12409
- Lohbauer U, Reich S. Antagonist wear of monolithic zirconia crowns after 2 years. Clin Oral Investig 2017;21:1165-72. https://doi.org/10.1007/s00784-016-1872-6
- Esquivel-Upshaw JF, Kim MJ, Hsu SM, Abdulhameed N, Jenkins R, Neal D, Ren F, Clark AE. Randomized clinical study of wear of enamel antagonists against polished monolithic zirconia crowns. J Dent 2018;68:19-27. https://doi.org/10.1016/j.jdent.2017.10.005
- Gou M, Chen H, Kang J, Wang H. Antagonist enamel wear of tooth-supported monolithic zirconia posterior crowns in vivo: A systematic review. J Prosthet Dent 2019;121:598-603. https://doi.org/10.1016/j.prosdent.2018.06.005
- Stober T, Johnson GH, Schmitter M. Accuracy of the newly formulated vinyl siloxanether elastomeric impression material. J Prosthet Dent 2010;103:228-39. https://doi.org/10.1016/S0022-3913(10)60035-2
- Hartkamp O, Lohbauer U, Reich S. Antagonist wear by polished zirconia crowns. Int J Comput Dent 2017;20: 263-74.
- Schlenz MA, Schlenz MB, Wostmann B, Jungert A, Ganss C. Intraoral scanner-based monitoring of tooth wear in young adults: 12-month results. Clin Oral Investig 2022;26:1869-78. https://doi.org/10.1007/s00784-021-04162-6
- Garcia VD, Freire Y, Fernandez SD, Murillo BT, Sanchez MG. Application of the intraoral scanner in the diagnosis of dental wear: an in vivo study of tooth wear analysis. Int J Environ Res Public Health 2022;19:4481.
- DeLong R. Intra-oral restorative materials wear: rethinking the current approaches: how to measure wear. Dent Mater 2006;22:702-11. https://doi.org/10.1016/j.dental.2006.02.003
- Hack GD, Patzelt SBM. Evaluation of the accuracy of six intraoral scanning devices: an in-vitro investigation. JADA 2015;10:1-5.
- O'Toole S, Osnes C, Bartlett D, Keeling A. Investigation into the accuracy and measurement methods of sequential 3D dental scan alignment. Dent Mater 2019; 35:495-500. https://doi.org/10.1016/j.dental.2019.01.012
- Derrien G, Le Menn G. Evaluation of detail reproduction for three die materials by using scanning electron microscopy and two-dimensional profilometry. J Prosthet Dent 1995;74:1-7. https://doi.org/10.1016/S0022-3913(05)80221-5
- Wang L, Liu Y, Si W, Feng H, Tao Y, Ma Z. Friction and wear behaviors of dental ceramics against natural tooth enamel. J European Ceram Soc 2012;32:2599-606. https://doi.org/10.1016/j.jeurceramsoc.2012.03.021
- Lee A, Swain M, He L, Lyons K. Wear behavior of human enamel against lithium disilicate glass ceramic and type III gold. J Prosthet Dent 2014;112:1399-405. https://doi.org/10.1016/j.prosdent.2014.08.002
- Delong R, Pintado MR, Douglas WH. The wear of enamel opposing shaded ceramic restorative materials: an in vitro study. J Prosthet Dent 1992;68:42-8. https://doi.org/10.1016/0022-3913(92)90282-F
- Peters MC, Delong R, Pintado MR, Pallesen U, Qvist V, Douglas WH. Comparison of two measurement techniques for clinical wear. J Dent 1999;27:479-85. https://doi.org/10.1016/S0300-5712(99)00027-5
- Ratledge DK, Smith BG, Wilson RF. The effect of restorative materials on the wear of human enamel. J Prosthet Dent 1994;72:194-203. https://doi.org/10.1016/0022-3913(94)90080-9
- Culhaoglu A, Park J. A comparison of the wear resistance and hardness of two different indirect composite resins with a ceramic material, opposed to human enamel. European J Gen Dent 2013;2:274.
- Ludovichetti FS, Trindade FZ, Werner A, Kleverlaan CJ, Fonseca RG. Wear resistance and abrasiveness of CAD-CAM monolithic materials. J Prosthet Dent 2018;120:318.e1-8. https://doi.org/10.1016/j.prosdent.2018.05.011
- Gimenez-Gonzalez B, Setyo C, Picaza MG, Tribst JPM. Effect of defect size and tooth anatomy in the measurements of a 3D patient monitoring tool. Heliyon 2022;8:e12103.
- Gimenez B, Ozcan M, Martinez-Rus F, Pradies G. Accuracy of a digital impression system based on active triangulation technology with blue light for implants: effect of clinically relevant parameters. Implant Dent 2015;24:498-504. https://doi.org/10.1097/ID.0000000000000283
- Ender A, Zimmermann M, Mehl A. Accuracy of complete- and partial-arch impressions of actual intraoral scanning systems in vitro. Int J Comput Dent 2019;22:11-9.