DOI QR코드

DOI QR Code

Experimental Study on Shear Retrofitting of Concrete Columns Using Iron-Based Shape Memory Alloy

철계 형상기억합금을 이용한 콘크리트 기둥의 전단보강 실험연구

  • Jung, Donghuk (School of Civil, Environmental and Architectural Engineering, Korea University) ;
  • Jeong, Saebyeok (Department of Civil, Environmental and Architectural Engineering, Korea University) ;
  • Choi, Jae-Hee (Department of Civil, Environmental and Architectural Engineering, Korea University) ;
  • Kim, Geunoh (Department of Civil, Environmental and Architectural Engineering, Korea University)
  • 정동혁 (고려대학교 건축사회환경공학부) ;
  • 정새벽 (고려대학교 건축사회환경공학과) ;
  • 최재희 (고려대학교 건축사회환경공학과) ;
  • 김근오 (고려대학교 건축사회환경공학과)
  • Received : 2023.11.08
  • Accepted : 2023.11.30
  • Published : 2024.01.01

Abstract

The current study investigates the seismic performance of shear-dominant RC columns retrofitted with iron-based shape memory alloy (Fe SMA). Three RC columns with insufficient transverse reinforcement were designed and fabricated for lateral cyclic loading tests. Before testing, two specimens were externally confined with carbon fiber-reinforced polymer (CFRP) sheets and self-prestressed Fe SMA strips. The test results showed that both CFRP and Fe SMA performed well in preventing severe shear failure exhibited by the unretrofitted control specimen. Furthermore, the two retrofitted specimens showed ductile flexural responses up to the drift ratios of ±8%. In terms of damage control, however, the Fe SMA confinement was superior to CFRP confinement in that the spalling of concrete was much less and that the rupture of confinement did not occur.

Keywords

Acknowledgement

본 논문은 고려대학교 특별연구비에 의하여 수행되었음.

References

  1. Hayashi T, Niwa H, Fukuhara M. Strengthening methods of the existing reinforced concrete buildings. In Proceedings of the 7th World Conference on Earthquake Engineering; 1980 Sep;4:89-97.
  2. Bett BJ, Klingner RE, Jirsa JO. Lateral load response of strengthened and repaired reinforced concrete columns. Structural Journal. 1988 Sep;85(5):499-508. https://doi.org/10.14359/9226
  3. Chai YH. Flexural retrofit of circular reinforced concrete bridge columns by steel jacketing. SSRP. 1991;91:06.
  4. Chai YH. An analysis of the seismic characteristics of steel-jacketed circular bridge columns. Earthquake Engineering & Structural Dynamics. 1996 Feb;25(2):149-161. https://doi.org/10.1002/(SICI)1096-9845(199602)25:2<149::AID-EQE543>3.0.CO;2-W
  5. Kim HC, Hong WK, Lee HJ. The Flexural behavior of a square concrete filled carbon tube columns under the constant axial force with reversed cyclic lateral load. Journal of the Earthquake Engineering Society of Korea. 2004;8(4):1-10. https://doi.org/10.5000/EESK.2004.8.4.001
  6. Park JW, Hong YK, Hong GS. Flexural strength design equation of concrete filled steel tube (CFT) column reinforced by carbon fiber sheet. Journal of the Earthquake Engineering Society of Korea. 2008;12(3):29-36. https://doi.org/10.5000/EESK.2008.12.3.029
  7. Jeon JS, Lee DH. Aftershock fragility assessment of damaged RC bridge piers repaired with CFRP jackets under successive seismic events. Journal of the Earthquake Engineering Society of Korea. 2018;22(5):271-280. https://doi.org/10.5000/EESK.2018.22.5.271
  8. Shin J, Jeon JS, Kim J. Numerical column model for damaged non-ductile reinforced concrete frame repaired using FRP jacketing system. Journal of the Earthquake Engineering Society of Korea. 2018;22(5):291-298. https://doi.org/10.5000/EESK.2018.22.5.291
  9. Hwang H, Kim H, Oh K, Shin J. Seismic retrofit scheme of FRP column jacketing system for non-seismic RC building frame. Journal of the Earthquake Engineering Society of Korea. 2023;27(6):293-301. https://doi.org/10.5000/EESK.2023.27.6.293
  10. Saatcioglu M, Yalcin C. External prestressing concrete columns for improved seismic shear resistance. Journal of Structural Engineering. 2003 Aug;129(8):1057-1070. https://doi.org/10.1061/(ASCE)0733-9445(2003)129:8(1057)
  11. Yamakawa T, Banazadeh M, Fujikawa S. Emergency retrofit of damaged RC columns right after seismic attack using pre-tensioned aramid fiber belts. In Proc., 1st Conf. on Applications of FRP Composites in Construction and Rehabilitation of Structures; c2004.
  12. Nesheli KN, Meguro K. Seismic retrofitting of earthquake-damaged concrete columns by lateral pre-tensioning of FRP belts. In Proc., 8th US National Conf. on Earthquake Engineering; 2006 Apr 18. El Cerrito, CA: Earthquake Engineering Research Institute (EERI).
  13. Shin M, Andrawes B. Experimental investigation of actively confined concrete using shape memory alloys. Engineering Structures. 2010 Mar;32(3):656-664. https://doi.org/10.1016/j.engstruct.2009.11.012
  14. Shin M, Andrawes B. Lateral cyclic behavior of reinforced concrete columns retrofitted with shape memory spirals and FRP wraps. Journal of Structural Engineering. 2011 Nov;137(11):1282-1290. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000364
  15. Jung D, Wilcoski J, Andrawes B. Bidirectional shake table testing of RC columns retrofitted and repaired with shape memory alloy spirals. Engineering structures. 2018 Apr;160:171-185. https://doi.org/10.1016/j.engstruct.2017.12.046
  16. Hong K, Lee S, Han S, Yeon Y. Evaluation of Fe-based shape memory alloy (Fe-SMA) as strengthening material for reinforced concrete structures. Applied Sciences. 2018 May;8(5):730.
  17. Jeong S, Kim KH, Lee Y, Yoo D, Hong K, Jung D. Compressive behavior of concrete confined with iron-based shape memory alloy strips. Earthquakes and Structures. 2022 Nov;23(5):431-444. https://doi.org/10.12989/EAS.2022.23.5.431
  18. Korea Concrete Institute, Design Code for Shear and Torsion of Concrete Structures (KDS 14 20 22). Korea Design Standard (KDS), Ministry of Land, Infrastructure, and Transport of Korea; c2022.
  19. American Concrete Institute Committee 440. Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures (ACI 440.2R-17). American Concrete Institute; c2017.
  20. American Concrete Institute Committee 374. Guide for testing reinforced concrete structural elements under slowly applied simulated seismic loads (ACI 374.2R-13). American Concrete Institute; c2013.
  21. American Society of Civil Engineers. Seismic evaluation and retrofit of existing buildings (ASCE/SEI 41-17). American Society of Civil Engineers; c2017.