Acknowledgement
이 논문은 정부(과학기술정보통신부)의 재원으로 한국연구재단의 지원을 받아 수행된 연구임.(No. 2020R1A5A8018822, RS-2024-00345535). 추가적인 연구비는 GS건설 사내벤처팀((주)제로넥스트머터리얼즈)으로부터 지원받음.
DOI QR Code
This study aims to confirm the feasibility of separating heavy metals and chlorine from fly ash generated in power plants and incinerators, enabling its potential reuse. A closed-loop Venturi system was used as the cavitation generator, applying the Bernoulli principle. Cavitation occurs when local pressure drops below the vapor pressure, and the energy released during the collapse of cavitation bubbles effectively detaches contaminants bound to the surface of the fly ash. Preliminary experiments visualizing cavitation in water confirmed the cavitation occurrence zone. After washing two types of fly ash, component analysis revealed a reduction in chlorine ions by 76-86.1% and lead by 89.5%. In additional experiments using a different fly ash sample, reductions in lead (80.7%), copper (99.5%), and hexavalent chromium (at least 63.6%) were observed. While there may be some errors due to measurement limitations, these results demonstrate the efficiency of this system in cleaning contaminated fly ash.
이 논문은 정부(과학기술정보통신부)의 재원으로 한국연구재단의 지원을 받아 수행된 연구임.(No. 2020R1A5A8018822, RS-2024-00345535). 추가적인 연구비는 GS건설 사내벤처팀((주)제로넥스트머터리얼즈)으로부터 지원받음.