The study investigates the application of Selective Catalytic Reduction (SCR) systems in steel manufacturing processes. To calculate the pressure drop occurring in the SCR system's catalytic plates under various operating conditions, we assumed a porous filter model. The pressure drop along the gas flow path is determined by theoretical calculations and computational simulations. The discrepancy in the data obtained from the both approach happens in the region of curved sections of SCR system where secondary flows occur. The pressure drop was calculated depending on different flow rate, by which a correlation between the pressure drop and the flow rate was made based on the simulation results. Inside the SCR system, boundary layer separation occurs before the SCR chamber, causing the flow to deviate in one direction. As a result, the flow uniformity decreases in the SCR chamber, which could lead to a decrease in the reaction performance on the catalytic plates. By installing baffles at the inlet region of the SCR chamber, the uniformity is enhanced by around 18.8% based on the standard deviation.