The First Performance-based Structural Fire Design for Office Building in Korea

  • Min Jae Park (Department of Architectural Engineering, Pukyong National University)
  • Published : 2023.09.11

Abstract

In this study, the fire resistance performance of the concrete-filled steel tube (CFT) columns and thin steel-plate composite (TSC) beams installed at a 20-story office building were designed using a performance-based structural fire design. Because of the lack of any specific provisions in the building code and guidelines for structural engineers about the performance-based approach, the only prescriptive approach has been selected for designing fire-resistant structures in Korea. To evaluate the fire resistance performance of the CFT columns and TSC beams, finite element analysis verified by the experimental results studied by several researchers was conducted with ABAQUS. From the fire scenario, the temperature distributions of the CFT columns and TSC beams were found via finite element analysis and the behaviors of the CFT columns and TSC beams were investigated in the structural field based on the temperature distribution.

Keywords

Acknowledgement

This work was supported by the Pukyong National University Research Fund in 2023(202303730001).

References

  1. Hurley, M.J. and Rosenbaum, E.R. (2015). Performance-based fire safety design. CRC Press, New York, USA. 
  2. The Federal Emergency Management Agency (FEMA) (2006). FEMA 453: Risk Management Series - Design Guidance for Shelters and Safe Rooms. USA. 
  3. Joyeux, D. Kruppa, J. Cajot, L.-G. Schleich, J.-B. van de Leur, P. and Twilt, L. (2002) Demonstration of real fire tests in car parks and high buildings. European Commission, Brussels, Belgium. 
  4. European Committee for Standardization (2005). EN 1992-1-3, Eurocode 3: Design of steel structure - Part 1-2: General rules - Structural fire design. Brussels, Belgium. 
  5. European Committee for Standardization (2004). EN 1992- 1-2, Eurocode 2: Design of concrete structure - Part 1-2: General rules - Structural fire design. Brussels, Belgium. 
  6. Ding, J. and Wang, Y.C. (2008). Realistic modelling of thermal and structural behaviour of unprotected concrete filled tubular columns in fire, Journal of Constrcutional Steel Research, 64, 1086-1102.  https://doi.org/10.1016/j.jcsr.2007.09.014
  7. Lu, H. Zhao, X.-L. Han, L.-H. (2011). FE modelling and fire resistance design of concrete filled double skin tubular columns. Journal of Constructional Steel Research, 67, 1733-1748.  https://doi.org/10.1016/j.jcsr.2011.04.014
  8. Espinos, A. Rmoero, M.L. Hospitaler, A. (2010). Advanced model for prediciting the fire response of concrete filled tubular columns. Journal of Constructional Steel Research, 66, 1030-1046.  https://doi.org/10.1016/j.jcsr.2010.03.002
  9. Choi, S.-K. and Kim, S.-B. (2008). Structural performance and heat transfer characteristics of the TSC composite beam in fire. Journal of the Architectural Institute of Korea, 24, 27-35.