과제정보
This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korean Government (2019M3E5D606387122, 2020R1A5A1018081, 2021M3A9I4021220). Purified GroEL and MmCpn proteins were kindly provided by Mingyu Jung and Sojeong Kim from the Lab of Molecular Imaging, SNU.
참고문헌
- Ahn, J., Lee, D., Jo, I., Jeong, H., Hyun, J.K., Woo, J.S., Choi, S.H., and Ha, N.C. (2020). Real-time measurement of the liquid amount in cryo-electron microscopy grids using laser diffraction of regular 2-D holes of the grids. Mol. Cells 43, 298-303.
- Armstrong, M., Han, B.G., Gomez, S., Turner, J., Fletcher, D.A., and Glaeser, R.M. (2020). Microscale fluid behavior during cryo-EM sample blotting. Biophys. J. 118, 708-719. https://doi.org/10.1016/j.bpj.2019.12.017
- Callaway, E. (2020). Revolutionary cryo-EM is taking over structural biology. Nature 578, 201.
- Dandey, V.P., Budell, W.C., Wei, H., Bobe, D., Maruthi, K., Kopylov, M., Eng, E.T., Kahn, P.A., Hinshaw, J.E., Kundu, N., et al. (2020). Time-resolved cryoEM using Spotiton. Nat. Methods 17, 897-900. https://doi.org/10.1038/s41592-020-0925-6
- Dubochet, J. and McDowall, A. (1981). Vitrification of pure water for electron microscopy. J. Microsc. 124, 3-4. https://doi.org/10.1111/j.1365-2818.1981.tb02483.x
- Ermantraut, E., Wohlfart, K., and Tichelaar, W. (1998). Perforated support foils with pre-defined hole size, shape and arrangement. Ultramicroscopy 74, 75-81. https://doi.org/10.1016/S0304-3991(98)00025-4
- Hohle, M.M., Lammens, K., Gut, F., Wang, B., Kahler, S., Kugler, K., Till, M., Beckmann, R., Hopfner, K.P., and Jung, C. (2022). Ice thickness monitoring for cryo-EM grids by interferometry imaging. Sci. Rep. 12, 15330.
- Huber, S.T., Sarajlic, E., Huijink, R., Weis, F., Evers, W.H., and Jakobi, A.J. (2022). Nanofluidic chips for cryo-EM structure determination from picoliter sample volumes. Elife 11, e72629.
- Jain, T., Sheehan, P., Crum, J., Carragher, B., and Potter, C.S. (2012). Spotiton: a prototype for an integrated inkjet dispense and vitrification system for cryo-TEM. J. Struct. Biol. 179, 68-75. https://doi.org/10.1016/j.jsb.2012.04.020
- Kim, H., Park, J., Lim, S., Jun, S.H., Jung, M., and Roh, S.H. (2021). Cryo-EM structures of GroEL:ES2 with RuBisCO visualize molecular contacts of encapsulated substrates in a double-cage chaperonin. iScience 25, 103704.
- Kim, S., Lee, S.S., Park, J.G., Kim, J.W., Ju, S., Choi, S.H., Kim, S., Kim, N.J., Hong, S., Kang, J.Y., et al. (2022). Structural insights into porphyrin recognition by the human ATP-binding cassette transporter ABCB6. Mol. Cells 45, 575-587. https://doi.org/10.14348/molcells.2022.0040
- Koning, R.I., Vader, H., van Nugteren, M., Grocutt, P.A., Yang, W., Renault, L.L.R., Koster, A.J., Kamp, A.C.F., and Schwertner, M. (2022). Automated vitrification of cryo-EM samples with controllable sample thickness using suction and real-time optical inspection. Nat. Commun. 13, 2985.
- Park, J., Park, J.Y., Lee, S., and Roh, S.H. (2020). Grid selection strategy for high-resolution cryo-EM. Biodesign 8, 41-48. https://doi.org/10.34184/kssb.2020.8.2.41
- Wei, H., Dandey, V.P., Zhang, Z., Raczkowski, A., Rice, W.J., Carragher, B., and Potter, C.S. (2018). Optimizing "self-wicking" nanowire grids. J. Struct. Biol. 202, 170-174. https://doi.org/10.1016/j.jsb.2018.01.001
- Weissenberger, G., Henderikx, R.J.M., and Peters, P.J. (2021). Understanding the invisible hands of sample preparation for cryo-EM. Nat. Methods 18, 463-471. https://doi.org/10.1038/s41592-021-01130-6
- Zhao, Y., Schmid, M.F., Frydman, J., and Chiu, W. (2021). CryoEM reveals the stochastic nature of individual ATP binding events in a group II chaperonin. Nat. Commun. 12, 4754.