Abstract

For fast-built and safe precast concrete (PC) construction, the dry mechanical splicing method is a critical technique that enables a self-sustaining system (SSS) during construction with no temporary support and minimizes onsite jobs. However, due to limited experimental evidence, traditional wet splicing methods are still dominantly adopted in the domestic precast industry. For PC beam-column connections, the current design code requires achieving emulative connection performances and corresponding structural integrity to be comparable with typical reinforced concrete (RC) systems with monolithic connections. To this end, this study conducted the standard material tests on mechanical splices to check their satisfactory performance as the Type 2 mechanical splice specified in the ACI 318 code. Two PC beam-column connection specimens with dry mechanical splices and an RC control specimen as the special moment frame were subsequently fabricated and tested under lateral reversed cyclic loadings. Test results showed that the seismic performances of all the PC specimens were fully comparable to the RC specimen in terms of strength, stiffness, energy dissipation, drift capacity, and failure mode, and their hysteresis responses showed a mitigated pinching effect compared to the control RC specimen. The seismic performances of the PC and RC specimens were evaluated quantitatively based on the ACI 374 report, and it appeared that all the test specimens fully satisfied the seismic performance criteria as a code-compliant special moment frame system.

Keywords

Acknowledgement

이 논문(연구실적물)은 2023학년도 충북대학교 연구년제 지원에 의하여 연구되었음

References

  1. Lee DJ, Lee JD, Oh TS, Kang THK. Seismic Experiment of Precast Concrete Exterior Beam-Column Joint using Bolt Type Connection and Prestressing Method. J Korea Concr Inst. 2014 Apr;26(2):125-133. https://doi.org/10.4334/JKCI.2014.26.2.125
  2. Kim SH, Kang THK, Jung DH, LaFave JM. Seismic behavior of precast and post-tensioned exterior connections with ductile headed rods. ACI Struct J. 2021 Jan;118(1):89-100. https://doi.org/10.14359/51728179
  3. Lee SS. An Experimental Study on Precast Concrete Beam-Column Connection with Headed Anchor for Small Building. J Architectural Institute of Korea. 2022 Jun;38(6):221-228.
  4. KS D 0249. Method of Inspection for Mechanical Splicing Joint of Bars for Concrete Reinforcement, Korean Standard Association. c2019.
  5. ACI Committee 374. Acceptance Criteria for Moment Frames based on structural testing and commentary (ACI 374.1-05). Farmington Hills, MI: American Concrete Institute; c2005. 9 p.
  6. ACI Committee 318. Building Code Requirements for Structural Concrete (ACI 318-19) and Commentary (ACI 318R-19). Farmington Hills, MI: American Concrete Institute; c2019. 624 p.
  7. Joint ACI-ASCE Committee 352. Recommendations for Design of Beam-Column Connections in Monolithic Reinforced Concrete Structures (ACI 352R-02). Farmington Hills, MI: American Concrete Institute; c2002. 38 p.
  8. Zhang W, Lee DH, Kim SH, Ju HJ, Lee CJ. Seismic Performance of Precast Wide Beam-Column Connections with Asymmetrical Anchorage Reinforcement Details. Engineering Structures. 2022 Oct;275:115237.
  9. American Society of Civil Engineers. Minimum Design Loads and Associated Criteria for Buildings and Other Structures (ASCE/SEC 7-22): Reston: c2022.