Abstract

The welding part of the valve needs immediate action when leakage occurs due to cracks or damage. In order to repair leakage of the welding part, the valve must be separated from the pipe or replaced with a new valve. However, it is difficult to remove the valve while operating the power plant. This study presents a method to remove leakage by precisely processing the gap between the clamp and the incision part within 0.1mm while installed in the pipe system. If the external leakage is removed using a clamp on the welding part without removing the valve during operation, the time and cost required for maintenance can be reduced.

Keywords

References

  1. ASME BPVC Sec.III, 2015, "Rules for Constructions of Nuclear Facility Components" American Society of Mechanical Engineers, NY.
  2. KEPIC MN, 2015, "Nuclear Mechanical" Korea Electric Power Industry Code.
  3. ASME BPVC Sec.XI, 2015, "Rules for Inservice Inspection of Nuclear Power Plant Components" American Society of Mechanical Engineers, NY.
  4. KEPIC MI, 2015, "Inservice Inspection of N.P.P" Korea Electric Power Industry Code.
  5. Jeong, C. W., 2012, Optimal design of Pipe Clamp Rib Plate(Reinforced) by Finite Element Analysis. Graduate School of Convergence Science and Technology, Gyeongsang National University, M.S. Thesis.
  6. ASME B16.34, 2017, "Valves - Flanged, Threaded, and Welding End", American Society of Mechanical Engineers, NY.
  7. KEPIC MGG, 2015, "Valves", Korea Electric Power Imperial Collage of Science Technology and Medicine, Ph.D Thesis. Industry Code
  8. ASME BPVC Sec.II, 2015, "Materials" American Society of Mechanical Engineers, NY.
  9. KEPIC MD, 2015, "Materials" Korea Electric Power Industry Code.
  10. Samshin R&D Department, Combined Design & Seismic Report (Class 900 18" CCCV), DR-HB4CLAMP-001 Rev.0, Sashin limited.