CAD-CAM 시스템과 Monolithic disc를 이용하여 상악 총의치, 하악 임플란트 유지 피개의치를 제작한 증례

Fabrication of maxillary complete denture and mandibular implant retained overdenture using CAD-CAM system and Monolithic disc: a case report

  • 노재혁 (전남대학교 치의학전문대학원 보철학교실) ;
  • 방혜민 (전남대학교 치의학전문대학원 보철학교실) ;
  • 장우형 (전남대학교 치의학전문대학원 보철학교실) ;
  • 박찬 (전남대학교 치의학전문대학원 보철학교실) ;
  • 임현필 (전남대학교 치의학전문대학원 보철학교실) ;
  • 박상원 (전남대학교 치의학전문대학원 보철학교실) ;
  • 윤귀덕 (전남대학교 치의학전문대학원 보철학교실)
  • Jaehyeok Ro (Department of Prosthodontics, School of Dentistry, Chonnam National University) ;
  • Haemin Bang (Department of Prosthodontics, School of Dentistry, Chonnam National University) ;
  • Woohyung Jang (Department of Prosthodontics, School of Dentistry, Chonnam National University) ;
  • Chan Park (Department of Prosthodontics, School of Dentistry, Chonnam National University) ;
  • Hyun-Pil Lim (Department of Prosthodontics, School of Dentistry, Chonnam National University) ;
  • Sangwon Park (Department of Prosthodontics, School of Dentistry, Chonnam National University) ;
  • Kwi-Dug Yun (Department of Prosthodontics, School of Dentistry, Chonnam National University)
  • 투고 : 2023.05.16
  • 심사 : 2023.06.03
  • 발행 : 2023.06.30

초록

CAD/CAM 시스템을 이용한 의치 제작은 환자의 내원 횟수를 감소시키고 기공과정에서 발생하는 오차를 감소시키는 장점이 있다. 본 환자는 상악 잔존치 발거에 따라 완전무치악 상태가 된 환자로, 하악 잔존치조제의 흡수로 기존 하악 총 의치의 유지와 안정이 부족하여 하악 임플란트 유지 피개의치 및 상악 총의치 수복을 계획하였다. 폐구상태에서 환자의 기능운동을 이용해 인상채득하는 BPS (Biofunctional prosthetic system)개념을 디지털화하여 Gnathometer CAD로 수직교합고경을 설정하고 고딕아치로 중심위를 인기하였으며 UTS CAD로 디지털 안궁이전하였다. CAD/CAM 시스템과 monolithic disc를 이용하여 제작한 상악 총의치, 하악 임플란트 유지 피개의치의 유지, 안정, 지지가 양호하며 환자는 향상된 의치 기능과 심미성에 만족하였기에 보고하는 바이다.

Fabrication of dentures using CAD/CAM system has the advantage of reducing the number of patient visits and reducing errors during laboratory work. After the extraction of maxillary residual teeth, this patient changed to a completely edentulous state and the stability and retention of the existing mandibular complete denture were insufficient due to the absorption of the mandibular residual ridge, so the restoration of the mandibular implant retained overdenture and maxillary complete denture were planned. By digitizing the concept of BPS (Biofunctional prosthetic system) that uses the patient's functional movement in closed mouth technique, the vertical dimension was taken by Gnathometer CAD and digital facebow transfer was performed using UTS CAD. In this case, fabrication of maxillary complete denture and mandibular implant-retained overdenture using monolithic disc and CAD/CAM system demonstrated favorable denture retention, stability, and support and the patient is satisfied with improved functions and esthetic of dentures.

키워드

참고문헌

  1. Kattadiyil MT, AlHelal A. An update on computer-engineered complete dentures: A systematic review on clinical outcomes. J Prosthet Dent 2017;117:478-85. https://doi.org/10.1016/j.prosdent.2016.08.017
  2. Abe J. Difference of preliminary impression takings between conventional mandibular complete denture and the mandibular complete denture intended with effective suction. Pract Prosthodont 2010;43:510-24.
  3. Pacquet W, Benoit A, Hatege-Kimana C, Wulfman C. Mechanical Properties of CAD/CAM Denture Base Resins. Int J Prosthodont 2019;32:104-6. https://doi.org/10.11607/ijp.6025
  4. Maeda Y, Minoura M, Tsutsumi S, Okada M, Nokubi T. A CAD CAM system for removable denture. Part 1: Fabrication of Complete denture. Int J Prosthdont 1994;7:17-21.
  5. Steinmassel PA, Klaunzer F, Steinmassel O, Dumfahrt H, Grunert I. Evaluation of currently available CAD/CAM Denture system. Int J Prosthodont 2017;30:116-22. https://doi.org/10.11607/ijp.5031
  6. Abualsaud R, Gad MM. Flexural Strength of CAD/CAM Denture Base Materials: Systematic Review and Meta-analysis of In-vitro Studies. J Int Soc Prev Community Dent 2022;12:160-70. https://doi.org/10.4103/jispcd.JISPCD_310_21
  7. Goodacre BJ, Goodacre CJ, Baba NZ, Kattadiyil MT. Comparison of denture base adaptation between CAD/CAM and conventional fabrication techniques. J Prosthet Dent 2016;116:249-56. https://doi.org/10.1016/j.prosdent.2016.02.017
  8. Sayed ME, Swaid SM, Porwal A. Effect of Cast Modification on Linear Dimensional Change of Acrylic Tooth Position Following Maxillary Complete Denture Processing. J Prosthodont 2017;26:659-63. https://doi.org/10.1111/jopr.12445
  9. Yamamoto S, Kanazawa M, Hirayama D, Nakamura T, Arakida T, Minakuchi S. In vitro evaluation of basal shapes and offset values of artificial teeth for CAD/CAM complete dentures. Comput Biol Med 2016;68:84-9. https://doi.org/10.1016/j.compbiomed.2015.11.004
  10. Yamamoto S, Kanazawa M, Iwaki M, Jokanovic A, Minakuchi S. Effects of offset values for artificial teeth positions in CAD/CAM complete denture. Comput Biol Med 2014;52:1-7. https://doi.org/10.1016/j.compbiomed.2014.05.011
  11. Ciocca L, Maltauro M, Cimini V, Breschi L, Montanari A, Anderlucci L, Meneghello R. Analysis of the trueness and precision of complete denture bases manufactured using digital and analog technologies. J Adv Prosthodont 2023;15:22-32. https://doi.org/10.4047/jap.2023.15.1.22